Differential Pulse Voltammetric Simultaneous Determination of Paracetamol and Omnipaque on Boron Doped Diamond Electrode: Application to Natural Tomato, Carrot, Cucumber Juices and Wastewater — Oak Academic Publishing
Research ArticleOpen AccessGoogle Scholar indexed
Differential Pulse Voltammetric Simultaneous Determination of Paracetamol and Omnipaque on Boron Doped Diamond Electrode: Application to Natural Tomato, Carrot, Cucumber Juices and Wastewater
UFR Environnement, Université Jean Lorougnon Guédé, Daloa, Côte d’Ivoire
,
UFR Environnement, Université Jean Lorougnon Guédé, Daloa, Côte d’Ivoire
,
UFR Sciences et Technologies, Université Alassane Ouattara, Bouaké, Côte d’Ivoire
,
Laboratoire de constitution et de réaction de la matière, UFR SSMT, Université Félix Houphouet Boiguy, Abidjan, Côte d’Ivoire
,
Laboratoire de constitution et de réaction de la matière, UFR SSMT, Université Félix Houphouet Boiguy, Abidjan, Côte d’Ivoire
,
Laboratoire de constitution et de réaction de la matière, UFR SSMT, Université Félix Houphouet Boiguy, Abidjan, Côte d’Ivoire
,
Laboratoire de constitution et de réaction de la matière, UFR SSMT, Université Félix Houphouet Boiguy, Abidjan, Côte d’Ivoire
1 UFR Environnement, Université Jean Lorougnon Guédé, Daloa, Côte d’Ivoire
2 UFR Environnement, Université Jean Lorougnon Guédé, Daloa, Côte d’Ivoire
This article describes the use of a boron-doped diamond electrode (BDDE) as an electrochemical sensor for the simultaneous determination of omnipaque (OMP) and paracetamol (PCM) in perchloric acid medium (HClO4 0.1 M) and in complex matrices such as tomato, carrot and cucumber juices and waste water from the Treichville University Hospital. Voltammetric studies allowed us to have well-defined oxidation peaks at distinct potentials of OMP (E = 0.5 V/SCE) and PCM (E = 0.7 V/SCE). Under optimized conditions, well-defined quantities of OMP and PCM, introduced simultaneously by metered additions, gave linear responses in concentration ranges of 259.8 - 467.2 μM for OMP and 58.73 - 116.3 μM PCM. The detection limits obtained are 7.23 μΜ and 3.6 μΜ respectively for OMP and PCM with recovery rates between 85.8% ± 0.1% and 92.6% ± 0.1% for OMP and between 99.9% ± 0.1% and 101.2% ± 0.4% for the PCM. This technique has been successfully used to simultaneously detect these pharmaceuticals in these complex environments. It allows recovery of OMP and PCM respectively up to 97.5% ± 0.0% and 91.6% ± 0.3% in tomato juice; 100.0% ± 0.0% and 95.2% ± 0.2% in carrot juice; 101.4% ± 0.1% and 97.3% ± 0.3% in cucumber juice; 100.1% ± 0.9% and 100.9% ± 0.1% in wastewater. The relevance of this technique for the simultaneous detection of OMP and PCM in tomato, carrot, cucumber juices and in waste water can be studied in the context of the contamination of certain fruits and vegetables by the substances organic pharmaceuticals released into the environment without prior treatment.
Schlüsener, M., Löffler, D. and Ternes, T. (2008) List of the Relevant PPs. Projet Européen KNAPPE, Deliverable D11, European Commission, 6th Framework Program, 63.
Sadezky, A., Löffler, D. and Ternes, T. (2008) Proposal of an Environmental Indicator and Classification System of Pharmaceutical Product Residues for Environmental Management. Projet Européen KNAPPE, Deliverable D12, European Commission, 6th Framework Program, 92.
Goyal, R.N. and Singh, S.P. (2006) Voltammetric Determination of Paracetamol at C60-Modified Glassy Carbon Electrode. Electrochimica Acta, 51, 3008-3012. https://doi.org/10.1016/j.electacta.2005.08.036
Dongre, V.G., Shah, S.B., Bayes, G.S., Phadke, M. and Jadhav, V.K. (2009) Simultaneous Determination of Etodolac and Acetaminophen in Tablet Dosage Form by RP-LC. Chromatographia, 69, 1019-1023. https://doi.org/10.1365/s10337-009-0974-6
Lv, X.D., Cui, Y.H., Xue, W.J., Yang, S.Q., Li, J.Y. and Liu, Z.Q. (2019) Comparison of Inert and Noninert Cathode in Cathode/Fe3t/Peroxymonosulfate Processes on Iohexol Degradation. Chemosphere, 223, 494-503. https://doi.org/10.1016/j.chemosphere.2019.02.079
Jeong, J., Jung, J., Cooper, W.J. and Song, W. (2010) Degradation Mechanisms and Kinetic Studies for the Treatment of X-Ray Contrast Media Compounds by Advanced Oxidation/Reduction Processes. Water Research, 44, 4391-4398. https://doi.org/10.1016/j.watres.2010.05.054
Tian, F.X., Xu, B., Lin, Y.L., Hu, C.Y., Zhang, T.Y. and Gao, N.Y. (2014) Photodegradation Kinetics of Iopamidol by UV Irradiation and Enhanced Formation of Iodinated Disinfection By-Products in Sequential Oxidation Processes., Water Research, 58, 198-208. https://doi.org/10.1016/j.watres.2014.03.069
Duirk, S.E., Lindell, C., Cornelison, C.C., Kormos, J., Ternes, T.A., Attene-Ramos, M., Osiol, J., Wagner, E.D., Plewa, M.J. and Richardson, S.D. (2011) Formation of Toxic Iodinated Disinfection By-Products from Compounds Used in Medical Imaging. Environmental Science & Technology, 45, 6845-6854. https://doi.org/10.1021/es200983f
Oulton, R.L., Kohn, T. and Cwiertny, D.M. (2010) Pharmaceuticals and Personal Care Products in Effluent Matrices: A Survey of Transformation and Removal during Wastewater Treatment and Implications for Wastewater Management. Journal of Environmental Monitoring, 12, 1956-1978. https://doi.org/10.1039/c0em00068j
Nikolaou, A., Meric, S. and Fatta, D. (2007) Occurrence Patterns of Pharmaceuticals in Water and Wastewater Environments. Analytical and Bioanalytical Chemistry, 387, 1225-1234. https://doi.org/10.1007/s00216-006-1035-8
Saracino, M.A., Petio, C., Vitali, M., Franchini, L. and Raggi, M.A. (2009) Determination of Orphenadrine Plasma Levels Using HPLC with Diode Array Detection and a Novel Solid-Phase Extraction Procedure in Psychiatric Patients. Journal of Pharmaceutical and Biomedical Analysis, 50, 501-506. https://doi.org/10.1016/j.jpba.2009.05.010
Wang, A., Sun, J., Feng, H., Gao, S. and He, Z. (2008) Simultaneous Determination of Paracetamol and Caffeine in Human Plasma by LC-ESI-MS. Chromatographia, 67, 281-285. https://doi.org/10.1365/s10337-007-0493-2
Arayane, M.S., Sultana, N. and Siddiqui, F.A. (2009) Simultaneous Determination of Paracetamol and Orphenadrine Citrate in Dosage Formulations and in Human Serum by RP-HPLC. Journal of the Chinese Chemical Society, 56, 169-174. https://doi.org/10.1002/jccs.200900024
Darwish, K., Salama, I., Mostafa, S. and El-Sadek, M. (2012) Validated Stability-Indicating Reversed-Phase-HPLC Method for Simultaneous Determination of Orphenadrine Citrate, Caffeine and Aspirin. Chemical and Pharmaceutical Bulletin, 60, 1426-1436. https://doi.org/10.1248/cpb.c12-00596
Walash, M.I., Belal, F.F., Eid, M.I. and Mohamed, S.A.A. (2011) Spectrophotometric Determination of Tizanidine and Orphenadrine via Ion Pair Complex Formation Using Eosin Y. Chemistry Central Journal, 5, Article No. 60. https://doi.org/10.1186/1752-153X-5-60
Dinc, E. and Onur, F. (1998) Application of a New Spectrophotometric Method for the Analysis of a Ternary Mixture Containing Metamizol, Paracetamol and Caffeine in Tablets. Analytica Chimica Acta, 359, 93-106. https://doi.org/10.1016/S0003-2670(97)00615-6
Khoshayand, M.R., Abdollahi, H., Shariatpanahi, M., Saadatfard, A. and Mohammadi, A. (2008) Simultaneous Spectrophotometric Determination of Paracetamol, Ibuprofen and Caffeine in Pharmaceuticals by Chemometric Methods. Spectrochimica Acta Part A, 70, 491-499. https://doi.org/10.1016/j.saa.2007.07.033
Li, S.J., Deng, D.-H., Pang, H., Liu, L., Xing, Y. and Liu, S.-R. (2012) Preparation of Electrochemically Reduced Graphene Oxide-Modified Electrode and Its Application for Determination of p-Aminophenol. Journal of Solid State Electrochemistry, 16, 2883-2889. https://doi.org/10.7312/li--16274-017
Svorc, L., Tomcik, P., Svtkov, J., Rievaj, M. and Bustin, D. (2012) Simultaneous Square-Wave Voltammetric Determination of Paracetamol, Caffeine and Orphenadrine in Pharmaceutical Formulations Using a Cathodically Pretreated Boron-Doped Diamond Electrode. Food Chemistry, 135, 1198-1204. https://doi.org/10.1016/j.foodchem.2012.05.052
Frag, E.Y.Z., Ali, T.A., Mohamed, G.G. and Awad, Y.H.H. (2012) Construction of Different Types of Ion-Selective Electrodescharacteristic Performances and Validation for Directpotentiometric Determination of Orphenadrine Citrate. International Journal of Electrochemical Science, 7, 4443-4464. https://doi.org/10.1016/S1452-3981(23)19552-6
Nebsen, M., Abd El-Rahman, M.K., El-Kosasy, A.M., Salem, M.Y. and El-Bardicy, M.G. (2011) Miniaturized Membrane Sensors for the Determination of Orphenadrine Citrate Portug. Electrochimica Acta, 29, 165-176. https://doi.org/10.4152/pea.201103165
Lourenao, B.C., Medeiros, R.A., Rocha-Filho, R.C., Mazo, L.H. and Fatibello-Filho, O. (2009) Simultaneous Voltammetric Determination of Paracetamol and Caffeine in Pharmaceutical Formulations Using a Boron-Doped Diamond Electrode. Talanta, 78, 748-752. https://doi.org/10.1016/j.talanta.2008.12.040
Sanghavi, B.J. and Srivastava, A.K. (2010) Simultaneous Voltammetric Determination of Acetaminophen, Aspirin and Caffeine Using an In-Situ Surfactant-Modified Multiwalled Carbon Nanotube Paste Electrode. Electrochimica Acta, 55, 8638-8648. https://doi.org/10.1016/j.electacta.2010.07.093
Ghorbani-Bidkorbeh, F., Shahrokhian, S., Mohammadi, A. and Dinarvand, R. (2010) Simultaneous Voltammetric Determination of Tramadol and Acetaminophen Using Carbon Nanoparticles Modified Glassy Carbon Electrode. Electrochimica Acta, 55, 2752-2759. https://doi.org/10.1016/j.electacta.2009.12.052
Silva, W.C., Pereira, P.F., Marra, M.C., Gimenes, D.T., Cunha, R.R., da Silva, R.A.B., Munoz, R.A.A. and Richter, E.M. (2012) A Simple Strategy for Simultaneous Determination of Paracetamol and Caffeine Using Flow Injection Analysis with Multiple Pulse Amperometric Detection. Electroanalysis, 23, 2764-2770. https://doi.org/10.1002/elan.201100512
Scholz, F. (2002) Electroanalytical Methods-Guide to Experiments and Applications. Springer, New York.
Kalayci, S., Ünal, U. and Somer, G. (2020) Determination of Vitamin B12 Using Differential Pulse Polarography. American Journal of Analytical Chemistry, 11, 187-196. https://doi.org/10.4236/ajac.2020.115014
Peckov, K., Musilov, J. and Barek, J. (2009) Boron-Doped Diamond Film Electrodes—New Tool for Voltammetric Determination of Organic Substances. Critical Reviews in Analytical Chemistry, 39, 148-172. https://doi.org/10.1080/10408340903011812
Sartori, E.R., Medeiros, R.A., Rocha-Filho, R.C. and Fatibello-Filho, O. (2009) Square-Wave Voltammetric Determination of Acetylsalicylic Acid in Pharmaceutical Formulations Using a Boron-Doped Diamond Electrode without the Need of Previous Alkaline Hydrolysis Step. Journal of the Brazilian Chemical Society, 20, 360-366. https://doi.org/10.1590/S0103-50532009000200022
Batista, E.F., Sartori, E.R., Medeiros, R.A., RochaFilho, R.C. and Fatibello-Filho, O. (2010) Differential Pulse Voltammetric Determination of Sildenafil Citrate (Viagra®) in Pharmaceutical Formulations Using a Boron-Doped Diamond Electrode. Analytical Letters, 43, 1046-1054. https://doi.org/10.1080/00032710903491153
Sartori, E.R., Medeiros, R.A., Rocha-Filho, R.C. and Fatibello-Filho, O. (2010) Square-Wave Voltammetric Determination of Propranolol and Atenolol in Pharmaceuticals Using a Boron-Doped Diamond Electrode. Talanta, 81, 1418-1424. https://doi.org/10.1016/j.talanta.2010.02.046
Ardila, J.A., Sartori, E.R., Rocha-Filho, R.C. and Fatibello-Filho, O. (2013) Square-Wave Voltammetric Determination of Bezafibrate in Pharmaceutical Formulations Using a Cathodically Pretreated Boron-Doped Diamond Electrode. Talanta, 103, 201-206. https://doi.org/10.1016/j.talanta.2012.10.033
Gil, J.S., Yanez, E.C. and Frontana-Uribe, B.A. (2022) Recent Advances on Boron Doped Diamond (BDD) Electrode as Cathode in Organic and Inorganic Preparative Electrotransformations. Current Opinion in Electrochemistry, 34, Article ID: 101004. https://doi.org/10.1016/j.coelec.2022.101004
Salazar-Banda, G.R. andrade, L.S., Nascente, P.A.P., Pizani, P.S., Rocha-Filho, R.C. and Avaca, L.A. (2006) The Changing Electrochemical Behaviour of Boron-Doped Diamond Surfaces with Time after Cathodic Pre-Treatments, Electrochimica Acta, 51, 4612-4619. https://doi.org/10.1016/j.electacta.2005.12.039
Koffi, K.M. and Ouattara, L. (2019) Electroanalytical Investigation on Paracetamol on Boron-Doped Diamond Electrode by Voltammetry. American Journal of Analytical Chemistry, 10, 562-578. https://doi.org/10.4236/ajac.2019.1011039
Zheng, M., Gao, F., Wang, Q., Cai, X., Jiang, S., Huang, L. and Fei, G. (2013) Electrocatalytical Oxidation and Sensitive Determination of Acetaminophen on Glassy Carbon Electrode Modified with Graphene-Chitosan Composite. Materials Science and Engineering C, 33, 1514-1520. https://doi.org/10.1016/j.msec.2012.12.055
Tanuja, S.B., Swamy, B.E.K. and Pai, K.V. (2017) Electrochemical Determination of Paracetamol in Presence of Folic Acid at Nevirapine Modified Carbon Paste Electrode: A Cyclic Voltammetric Study. Journal of Electroanalytical Chemistry, 798, 17-23. https://doi.org/10.1016/j.jelechem.2017.05.025
Koffi, K.M. and Ouattara, L. (2019) Differential Pulse Voltammetric Determination of Paracetamol on a Boron-Doped Diamond Electrode: Application to Natural Tomato and Carrot Juices. Revue Ivoirienne des Sciences et Technologie, 34, 44-66.
Koffi, K.S., Foffié, T.A.A., Kouadio, K.E., Kimou, K.J., Kone, S. and Ouattara, L. (2021) Cyclic and Differential Pulse Voltammetry Investigations of an Iodine Contrast Product Using Microelectrode of BDD. Mediterranean Journal of Chemistry, 11, 244-254.