Rapid and Sensitive Carvedilol Assay in Human Plasma Using a High-Performance Liquid Chromatography with Mass/Mass Spectrometer Detection Employed for a Bioequivalence Study
- 1
- 2
- 3
Abstract
A method for the determination of carvedilol in human plasma was developed using a high-performance liquid chromatography with tandem mass spectrometer (HPLC-MS/MS). Plasma samples were deproteinized using acetonitrile and the supernatant was directly injected onto the HPLC column without any preparative steps. Chromatography was performed on a reversed-phase (C18) column with isocratic mobile phase for 2 min. The calibration curve was linear over the range of 2 to100 ng/ml (R2 > 0.9998) and the lower limit of quantitation (LLOQ) was 2 ng/ml. This method showed acceptable precision and accuracy, good recovery from the plasma matrix, and stability during the analytical procedures. When its application to the bioequivalence test of two carvedilol 25 mg tablet formulations in male healthy 28 volunteers, this validated analysis method was appropriate resulting in the bioequivalence of two formulations: no statistically significant difference was observed between the logarithmic transformed area under curve (AUC) and maximum plasma concentration (Cmax) values of the two formulations. The 90% confidence interval for the ratio of the above mentioned two parameters were within the bioequivalence limit of 0.80-1.25. These results suggested that the HPLC-MS/MS analysis method developed was suitable for the carvedilol analysis in human plasma.
- F. Varin, L. X. Cubeddu and J. R. Powell, “Liquid Chromatographic Assay and Disposition of Carvedilol in Healthy Volunteers,” Journal of Pharmaceutical Sciences, Vol. 75, No. 12, 1986, pp. 1195-1197.
- E. J. Eisenberg, W. R. Patterson and G. C. Khan, “High-Performance Liquid Chromatographic Method for the Simultaneous Determination of the Enantiomers of Carvedilol and Its O-Desmethyl Metabolite in Human Plasma after Chiral Derivatization,” Journal of Chromatography B, Vol. 493, No. 1, 1989, pp. 105-115.
- G. M. Keating and B. Jarvis, “Carvedilol: A Review of Its Use in Chronic Heart Failure,” Drugs, Vol. 63, No. 16, 2003, pp. 1697-1741.
- T. W. Gehr, D. M. Tenero, D. A. Boyle, Y. Qian, D. A. Sica and N. H. Shusterman, “The Pharmacokinetics of Carvedilol and Its Metabolites after Single and Multiple Dose Oral Administration in Patients with Hypertension and Renal Insufficiency,” European Journal of Clinical Pharmacology, Vol. 55, No. 4, 1999, pp. 269-277.
- R. R. Ruffolo, M. Gellai, J. P. Heible, R. N. Willette and A. J. Nicholas, “Hemodynamic Differences between Carvedilol and Labetalol in the Cutaneous Circulation,” European Journal of Clinical Pharmacology, Vol. 38, No. (Suppl)2, 1990, pp. S112-S114.
- N. Hokama, N. Hobara, H. Kameya, S. Ohshiro and M. Sakanashi, “Rapid and Simple Micro-Determination of Carvedilol in Rat Plasma by High-Performance Liquid Chromatography,” Journal of Chromatography B, Vol. 732, No. 1, 1999, pp. 233-238.
- F. Behn, S. L?er and H. Scholz, “Determination of Carvedilol in Human Cardiac Tissue by High Performance Liquid Hromatography,” Journal of Chromatogra- phic Science, Vol. 39, No. 3, 2001, pp. 121-124.
- P. Ptacek, J. Macek and J. Klima, “Liquid Chromatographic Determination of Carvedilol in Human Plasma,” Journal of Chromatography B, Vol. 789, No. 2, 2003, pp. 405-410.
- L. Clohs and K. M. McErlane, “Comparison between Capillary Electrophoresis and High-Performance Liquid Chromatography for the Stereoselective Analysis of Carvedilol in Serum,” Journal of Pharmaceutical and Biomedical Analysis, Vol. 31, No. 3, 2003, pp. 407-412.
- M. Saito, J. Kawana, T. Ohno, M. Kanako, K. Mihara, K. Hanada, R. Sugita, N. Okada, S. Osato, M. Nagayama. T. Sumiyoshi and H. Ogata, “Enantioselective and Highly Sensitive Determination of Carvedilol in Human Plasma and Whole Blood after Administration of the Racemate Using Normal-Phase High-Performance Liquid Chromatography,” Journal of Chromatography B, Vol. 843, No. 1, 2006, pp. 73-77.