Reversible Immobilization of Chelating Affinity Surfactants on Reversed Phase Adsorbents for Protein and Peptide Separations under Metal Affinity Chromatography — Oak Academic Publishing
Research ArticleOpen AccessGoogle Scholar indexed
Reversible Immobilization of Chelating Affinity Surfactants on Reversed Phase Adsorbents for Protein and Peptide Separations under Metal Affinity Chromatography
Bioprocess Engineering Department, Autonomous University of San Luis Potosí, San Luis Potosí, México
,
Chemical and Environmental Engineering Department, The University of Arizona, Tucson, USA
1 Bioprocess Engineering Department, Autonomous University of San Luis Potosí, San Luis Potosí, México
2 Chemical and Environmental Engineering Department, The University of Arizona, Tucson, USA
Alkyl-bound silica was modified using chelating surfactants and the resulting adsorbent was used in immobilized metal affinity chromatography of proteins and peptides. Brij-76, a non-ionic amphiphilic surfactant with an alkyl moiety and an ethylene oxide chain, was reversible adsorbed to alkyl silica (C 18 ). The hydroxyl group at the end of the ethylene oxide chain was chemically modified previously with an iminodiacetate functionality as chelating agent of transitional metal ions. Cu(II) was studied as immobilized ion for the adsorption of peptides and proteins. Three chromatographic supports were prepared having different Cu(II) capacities. For a low Cu(II) capacity case, the generated adsorbent behaved as a controlled access media preventing the adsorption of large molecular weight proteins, such as BSA, while small peptides, such as Angiotensin III, or amino acids could be retained. For a medium and high Cu(II) capacity, the synthesized adsorbent no longer behaved as a controlling access media and all molecules in this study, either large or small, were retained by the immobilized ion. Nonetheless, most of the BSA was strongly retained by the system and a pH change did not remove any of the adsorbed BSA while the small molecules were removed by the same pH change.
Regnier, F.E. (1987) HPLC of Biological Macromolecules: The First Decade. Chromatographia, 24, 241-251. http://dx.doi.org/10.1007/BF02688486
Riordain, C.O., Barron, L., Nesterenko, E., Nesterenko, P.N. and Paull, B. (2006) Double Gradient Ion Chromatography Using Short Monolithic Columns Modified with a Long Chained Zwitterionic Carboxybetaine Surfactant. Journal of Chromatography A, 1109, 111-119. http://dx.doi.org/10.1016/j.chroma.2006.01.002
Kelmers, A.D., Novelli, G.D. and Stulberg, M.P. (1965) Separation of Transfer Ribonucleic Acids by Reverse Phase Chromatography. Journal of Biological Chemistry, 240, 3979-3983.
Weiss, J.F., Pearson, R.L. and Kelmers, A.D. (1968) Two Additional Reversed-Phase Chromatographic Systems for the Separation of Transfer Ribonucleic Acids and Their Application to the Preparation of Two Formylmethionine and a Valine Transfer Ribonucleic Acid from Escherichia coli B. Biochemistry, 7, 3479-3487. http://dx.doi.org/10.1021/bi00850a024
Bischoff, R., Graeser, E. and McLaughlin, L.W. (1983) tRNA Separation by High-Performance Liquid Chromatography Using an Aggregate of Ods-Hypersil and Trioctylmethylammonium Chloride. Journal of Chromatography, 257, 305-315. http://dx.doi.org/10.1016/S0021-9673(01)88186-3
Bischoff, R. and McLaughlin, L.W. (1985) Isolation of Specific tRNAs Using an Ionic-Hydrophobic Mixed-Mode Chromatographic Matrix. Analytical Biochemistry, 151, 526-533. http://dx.doi.org/10.1016/0003-2697(85)90215-5
Chang, J.P. (1984) Effect of Surfactants on the Separation of Proteins by Reversed-Phase High-Performance Liquid Chromatography. I. Non-Ionic Surfactants (Tween). Journal of Chromatography, 317, 157-163. http://dx.doi.org/10.1016/S0021-9673(01)91655-3
Torres, J.L., Guzman, R., Carbonell, R.G. and Kilpatrick, P.K. (1988) Affinity Surfactants as Reversibly Bound Ligands for High-Performance Affinity Chromatography. Analytical Biochemistry, 171, 411-418. http://dx.doi.org/10.1016/0003-2697(88)90507-6
Guzman, R., Torres, J.L., Carbonell, R.G. and Kilpatrick, P.K. (1989) Water-Soluble Nonionic Surfactants for Affinity Bioseparations. Biotechnology and Bioengineering, 33, 1267-1276. http://dx.doi.org/10.1002/bit.260331007
Keller, D.E., Torres, J.L., Carbonell, R.G. and Kilpatrick, P.K. (1989) Reversible Conversion of Octadecyl-Bonded Silica to Ion-Exchange Surfaces for Protein Separations. Analytical Biochemistry, 176, 191-198. http://dx.doi.org/10.1016/0003-2697(89)90292-3
Sing, Y.L.K., Algiman, E., Kroviarski, Y., Massot, C., Dhermy, D. and Bertrand, O. (1991) Modification of Reversed-Phase Column with Dyed Surfactants. Preparation of Mechanically Resistant Efficient Immobilized Dyes for Protein Purification. Journal of Chromatography A, 558, 43-54. http://dx.doi.org/10.1016/0021-9673(91)80110-3
Desilets, C.P., Rounds, M.A. and Regnier, F.E. (1191) Semipermeable-Surface Reversed-Phase Media for High-Performance Liquid Chromatography. Journal of Chromatography A, 544, 25-39. http://dx.doi.org/10.1016/S0021-9673(01)83976-5
Sing, Y.L.K., Kroviarski, Y., Cochet, S., Dhermy, D. and Bertrand, O. (1992) High-Performance Hydrophobic Interaction Chromatography of Proteins on Reversed-Phase Supports Coated with Non-Ionic Surfactants of Polyoxyethylene Type Purification of a Fungal Aspartic Proteinase. Journal of Chromatography A, 598, 181-187. http://dx.doi.org/10.1016/0021-9673(92)85046-V
Gombotz, W.R., Guanghui, W., Horbett, T.A. and Hoffman, A.S. (1991) Protein Adsorption to Poly(ethylene Oxide) Surfaces. Journal of Biomedical Materials Research, 25, 1547-1562. http://dx.doi.org/10.1002/jbm.820251211
Porath, J., Carlsson, J., Olsson, I. and Belfrage, G. (1975) Metal Chelate Affinity Chromatography, a New Approach to Protein Fractionation. Nature, 258, 598-599. http://dx.doi.org/10.1038/258598a0
Gutiérrez, R., del Valle, E.M.M. and Galán, M.A. (2007) Immobilized Metal-Ion Affinity Chromatography: Status and Trends. Separation and Purification Reviews, 36, 71-111. http://dx.doi.org/10.1080/15422110601166007
Ho, C., Limberis, L., Caldwell, K.D. and Stewart, R.J. (1998) A Metal-Chelating Pluronic for Immobilization of Histidine-Tagged Proteins at Interfaces: Immobilization of Firefly Luciferase on Polystyrene Beads. Langmuir, 14, 3889-3894. http://dx.doi.org/10.1021/la980148k
Bradford, M.M. (1976) A Rapid and Sensitive Method for the Quantitation of Microgram Quantities of Protein Utilizing the Principle of Protein-Dye Binding. Analytical Biochemistry, 72, 248-254. http://dx.doi.org/10.1016/0003-2697(76)90527-3
Berthod, A. and Coque, C.G.A. (2000) Micellar Liquid Chromatography. Marcel Dekker, Inc., New York.
Borgerding, M.F., Hinze, W.L., Stafford, L.D., Fulp, G.W. and Hamlin Jr., W.C. (1989) Investigations of Stationary Phase Modification by the Mobile Phase Surfactant in Micellar Liquid Chromatography. Analytical Chemistry, 61, 1353-1358. http://dx.doi.org/10.1021/ac00188a011
Borgerding, M.F., Williams, R.L., Hinze, W.L. and Quina, F.H. (1989) New Perspectives in Micellar Liquid Chromatography. Journal of Liquid Chromatography, 12, 1367-1406. http://dx.doi.org/10.1080/01483918908049512
Rosen, M.J. (2004) Surfactants and Interfacial Phenomena. John Wiley & Sons, Inc., Hoboken. http://dx.doi.org/10.1002/0471670561
Smith, M.C., Furman, T.C. and Pidgeon, C. (1987) Immobilized Iminodiacetic Acid Metal Peptide Complexes. Identification of Chelating Peptide Purification Handles for Recombinant Proteins. Inorganic Chemistry, 26, 1965-1969. http://dx.doi.org/10.1021/ic00259a030
Morra, M. (2000) On the Molecular Basis of Fouling Resistance. Journal of Biomaterials Science, Polymer Edition, 11, 547-569. http://dx.doi.org/10.1163/156856200743869
Szleifer, I. (1997) Protein Adsorption on Surfaces with Grafted Polymers: A Theoretical Approach. Biophysical Journal, 72, 595-612. http://dx.doi.org/10.1016/S0006-3495(97)78698-3
Halperin, A. (1999) Polymer Brushes That Resist Adsorption of Model Proteins: Design Parameters. Langmuir, 15, 2525-2533. http://dx.doi.org/10.1021/la981356f
Wattendorf, U. and Merkle, H.P. (2008) PEGylation as a Tool for the Biomedical Engineering of Surface Modified Microparticles. Journal of Pharmaceutical Sciences, 97, 4655-4669. http://dx.doi.org/10.1002/jps.21350
Sulkowski, E. (1985) Purification of Proteins by IMAC. Trends in Biotechnology, 3, 1-7. http://dx.doi.org/10.1016/0167-7799(85)90068-X
Sharma, S. and Agarwal, G.P. (2001) Interactions of Proteins with Immobilized Metal Ions: A Comparative Analysis Using Various Isotherm Models. Analytical Biochemistry, 288, 126-140. http://dx.doi.org/10.1006/abio.2000.4894
Cross, J. (1987) Nonionic Surfactants. Chemical Analysis. Marcel Dekker, Inc., New York.
Holmberg, K., Jonsson, B., Kronberg, B. and Lindman, B. (2003) Surfactants and Polymers in Aqueous Solutions. John Wiley & Sons, West Sussex.
Berthod, A., Tomer, S. and Dorsey, J.G. (2001) Polyoxyethylene Alkyl Ether Nonionic Surfactants: Physicochemical Properties and Use for Cholesterol Determination in Food. Talanta, 55, 69-83. http://dx.doi.org/10.1016/S0039-9140(01)00395-2
Belew, M. and Porath, J. (1991) Immobilized Metal Ion Affinity Chromatography. Effect of Solute Structure, Ligand Density and Salt Concentration on the Retention of Peptides. Journal of Chromatography A, 516, 333-354. http://dx.doi.org/10.1016/S0021-9673(01)89275-X