Simultaneous Determination of Dopamine and L-Ascorbic Acid by Modified Carbon Paste Electrode with Ni (II) Cyclam Complex
- 1
- 2
Abstract
The electroanalysis of dopamine (DA) and ascorbic acid (AA) by square wave voltammetry has been performed at a modified carbon paste electrode with macrocyclic ligand 1, 4, 8, 11-tetraazacyclotetradecane (cyclam) and monolayer of Ni (II) cyclam. In pH 7.2 buffer solutions, the electrostatic reaction of AA with di-positive monolayer shifts the oxidation potential to less positive potential, while the electrostatic repulsion of DA with the monolayer shifts the oxidation potential of DA to more positive potential. The separation between the oxidation peaks of AA and DA at the present di-positive monolayer modified electrode (252 mV) was larger than that (187 mV) at the cyclam modified electrode. In addition, the catalytic oxidation of AA by oxidized DA has been advantageously eliminated at the modified carbon paste electrode with cyclam and Ni (II) cyclam complex. Thus, the determination of DA in the presence of an excess of AA is possible with the present modified electrodes.
- [1] H. Zhao, Y. Zhang and Z. Yuan, “Electrochemical Determination of Dopamine Using a Poly (2-Picolinic Acid) Modified Glassy Carbon Electrode,” Analyst, Vol. 126, No. 3, 2001, pp. 358-360. doi:10.1039/b008283j
- T. E. Smith, “Text Book of Biochemistry with Clinical Correlations,” T. M. Devlin Eds., Wiley/Liss, New York, 1992, p. 929.
- O. Gilbert, U. Chandra, B. E. Kumara Swamy, M. Panduranga Char, C. Nagaraj and B. S. Sherigara, “Poly (Alanine) Modified Carbon Paste Electrode for Simultaneous Detection of Dopamine and Ascorbic Acid,” International Journal of Electrochemical Science, Vol. 3, No. 3, 2008, pp. 1186-1195.
- M. Rohani Moghadam, S. Dadfarnia, A. M. Haji Shabani and P. Shahbazikhah, “Chemometric-Assisted Kinetic–Spectrophotometric Method for Simultaneous Determination of Ascorbic Acid, Uric Acid, and Dopamine,” Analytical Biochemistry, Vol. 410, No. 2, 2011, pp. 289-295. doi:10.1016/j.ab.2010.11.007
- W. Zhang, X. Cao, Y. Xie, S. Ai, L. Jin and J. Jin, “Simultaneous Determination of the Monoamine Neurotransmitters and Glucose in Rat Brain by Microdialysis Sampling Coupled with Liquid Chromatography-Dual Electrochemical Detector,” Journal of Chromatography B, Analytical Technologies in the Biomedical and Life Sciences, Vol. 785, No. 2, 2003, pp. 327-336. doi:10.1016/S1570-0232(02)00953-4
- C. Muzzi, E. Bertocci, L. Terzuoli, B. Porcelli, I. Ciari, R. Pagani and R. Guerranti, “Simultaneous Determination of Serum Concentrations of Levodopa, Dopamine, 3-O-Methyldopa and α-Methyldopa by HPLC,” Biomedicine & Pharmacotherapy, Vol. 62, No. 4, 2008, pp. 253-258. doi:10.1016/j.biopha.2007.10.018
- H. Li, C. Li, Z. Y. Yan, J. Yang and H. Chen, “Simultaneous Monitoring Multiple Neurotransmitters and Neuromodulators During Cerebral Ischemia/Reperfusion in Rats by Microdialysis and Capillary Electrophoresis,” Journal of Neuroscience Methods, Vol. 189, No. 2, 2010, pp. 162-168. doi:10.1016/j.jneumeth.2010.03.022
- M. Pandurangachar, B. E. Kumara Swamy, B. N. Chandrashekar, O. Gilbert and B. S. Sherigara “Electrochemical Deposition of 1-Butyl-4-Methyl-Pyridinium Tetrafluroborate Ionic Liquid on Carbon Paste Electrode and its Application for the Simultaneous Determination of Dopamine, Ascorbic Acid and Uric Acid,” Journal of Molecular Liquids, Vol. 158, No. 1, 2011, pp. 13-17. doi:10.1016/j.molliq.2010.09.005
- R. Zhang, G. D. Jin, D. Chen and X. Y. Hu “Simultaneous Electrochemical Determination of Dopamine, Ascorbic Acid and Uric Acid Using Poly (Acid Chrome Blue K) Modified Glassy Carbon Electrode,” Sensors and Actuators B: Chemical, Vol. 138, No. 1, 2009, pp. 174-181.