Abstract
A theoretical model for the non steady-state response of a pH-based potentiometric biosensor immobilizing organophosphorus hydrolase (OPH) is discussed. The model is based on a system of five coupled nonlinear reaction-diffusion equations under non steady-state conditions for enzyme reactions occurring in potentiometric biosensor that describes the concentration of substrate and hydrolysis products within the membrane. New approximate analytical expressions for the concentration of the substrate (organophosphorus pesticides (OPs)) and products are derived for all values of Thiele modulus and buffer concentration using new approach of homotopy perturbation method. The analytical results are also compared with numerical ones and a good agreement is obtained. The obtained results are valid for the whole solution domain.
- Baronas, R., et al. (2010) Mathematical Modeling of Biosensors: An Introduction for Chemists and Mathematicians. Springer. http://dx.doi.org/10.1007/978-90-481-3243-0
- Sahin, A. (2012) Development of Electrochemical Methods for Detection of Pesticides and Biofuel Production. Ph.D. Thesis, Columbia University Academic Commons.
- Rajendran, L. (2013) Chemical Sensors Simulation and Modeling, Electrochemical Sensors. In: Korotchenkov, G., Ed.
- Meena, A. and Rajendran, L. (2010) Analysis of a pH-Based Potentiometric Biosensor Using the Homotopy Perturbation Method. Chemical Engineering & Technology, 33, 1-10. http://dx.doi.org/10.1002/ceat.200900580
- Rahamathunissa, G. and Rajendran, L. (2008) Application of He’s Variational Iteration Method in Nonlinear Boundary Value Problems in Enzyme—Substrate Reaction Diffusion Processes: Part 1. The Steady-State Amperometric Response. Journal of Mathematical Chemistry, 44, 849-861. http://dx.doi.org/10.1007/s10910-007-9340-9
- Manimozhi, P., Subbiah, A. and Rajendran, L. (2010) Solution of Steady-State Substrate Concentration in the Action of Biosensor Response at Mixed Enzyme Kinetics. Sensors and Actuators B, 147, 290-297. http://dx.doi.org/10.1016/j.snb.2010.03.008
- Dong, S. and Che, G. (1991) Electrocatalysis at a Microdisk Electrode Modified with a Redox Species. Journal of Electroanalytical Chemistry, 309, 103-114. http://dx.doi.org/10.1016/0022-0728(91)87007-Q
- Lyons, M.E.G., Bannon, T. and Rebouillat, S. (1998) Reaction/Diffusion at Conducting Polymer Ultramicroelectrodes. Analyst, 123, 1961-1966. http://dx.doi.org/10.1039/a804039g
- Eswari, A. and Rajendran, L. (2010) Analytical Solution of Steady-State Current an Enzyme-Modified Microcylinder Electrodes. Journal of Electroanalytical Chemistry, 648, 36-46. http://dx.doi.org/10.1016/j.jelechem.2010.07.002
- Wang, L.H., Zhang, L., Huang, J.X. and Chen, H.L. (2006) Model of a pH-Based Potentiometric Biosensor Immobilizing Organophosphorus Hydrolase. Chemical Engineering & Technology, 29, 462-467. http://dx.doi.org/10.1002/ceat.200500281
- He, J.-H. (2006) Some Asymptotic Methods for Strongly Nonlinear Equations. International Journal of Modern Physics, 20, 1141-1199. http://dx.doi.org/10.1142/S0217979206033796
- He, J.-H. (1999) Homotopy Perturbation Technique. Computer Methods in Applied Mechanics and Engineering, 178, 257-262. http://dx.doi.org/10.1016/S0045-7825(99)00018-3