Validation and Comparison of Two Calibration Methods for the Measurement of Stable Iodine in the Urinary Matrix by ICP-MS: Standard Addition vs. External Calibration — Oak Academic Publishing
Research ArticleOpen AccessGoogle Scholar indexed
Validation and Comparison of Two Calibration Methods for the Measurement of Stable Iodine in the Urinary Matrix by ICP-MS: Standard Addition vs. External Calibration
Institute for Radiological Protection and Nuclear Safety (IRSN), Fontenay-aux-Roses, France
,
Institute for Radiological Protection and Nuclear Safety (IRSN), Fontenay-aux-Roses, France
,
Institute for Radiological Protection and Nuclear Safety (IRSN), Fontenay-aux-Roses, France
,
Institute for Radiological Protection and Nuclear Safety (IRSN), Fontenay-aux-Roses, France
,
Institute for Radiological Protection and Nuclear Safety (IRSN), Fontenay-aux-Roses, France
,
Institute for Radiological Protection and Nuclear Safety (IRSN), Fontenay-aux-Roses, France
,
Institute for Radiological Protection and Nuclear Safety (IRSN), Fontenay-aux-Roses, France
,
The French Alternative Energies and Atomic Energy Commission (CEA), Gif-sur-Yvette, France
,
Institute for Radiological Protection and Nuclear Safety (IRSN), Fontenay-aux-Roses, France
,
Institute for Radiological Protection and Nuclear Safety (IRSN), Fontenay-aux-Roses, France
1 Institute for Radiological Protection and Nuclear Safety (IRSN), Fontenay-aux-Roses, France
2 Institute for Radiological Protection and Nuclear Safety (IRSN), Fontenay-aux-Roses, France
3 Institute for Radiological Protection and Nuclear Safety (IRSN), Fontenay-aux-Roses, France
4 Institute for Radiological Protection and Nuclear Safety (IRSN), Fontenay-aux-Roses, France
5 Institute for Radiological Protection and Nuclear Safety (IRSN), Fontenay-aux-Roses, France
6 Institute for Radiological Protection and Nuclear Safety (IRSN), Fontenay-aux-Roses, France
7 Institute for Radiological Protection and Nuclear Safety (IRSN), Fontenay-aux-Roses, France
8 The French Alternative Energies and Atomic Energy Commission (CEA), Gif-sur-Yvette, France
9 Institute for Radiological Protection and Nuclear Safety (IRSN), Fontenay-aux-Roses, France
10 Institute for Radiological Protection and Nuclear Safety (IRSN), Fontenay-aux-Roses, France
Background : In the context of a nuclear reactor accident, thyroid is the main target organ of radioactive iodines. To avoid as much as possible thyroid disorders or even cancer development, it is recommended to administer a single dose of potassium iodide to people at risk of exposure. Nevertheless, the Fukushima Dai-ichi disaster has pointed out many questions about the conditions of stable iodine prophylaxis implementation highlighting the need for reflection further revision of the actual “iodine doctrine”. Therefore, providing useful data is required notably through the implementation of animal experiments to strengthen current knowledge and to edit new recommendations. Methods : Urinary iodine constitutes a very good indicator to investigate the function of thyroid, its interpretation demands reliable analyses. Prior to perform animal experiments, two calibration methods were designed by our lab and compared together (standard addition and external calibration) to assess the urinary concentration of stable iodine in urine by ICP-MS. They were validated based on several key parameters especially linearity, accuracy and limits of detection (LOD) and quantification (LOQ). Results : The results were nicely satisfying. Indeed, both calibration methods have indicated very good coefficients of correlations, accuracies with low expanded relative uncertainties were obtained. The estimated LOD in the sample for standard addition method and external calibration were fully acceptable, 0.39 μg·L -1 and 0.35 μg·L -1 , respectively. All performance criteria have been thus fulfilled successfully. The established methods were proven to be accurate, robust and sensitive. Once validated, both calibration methods were applied to rat urine samples and the results of z-score and Wilcoxon W test concluded that there were no statistically significant differences between both methods.
Hays, M.T. (2001) Estimation of total body iodine in normal young men. Thyroid, 11, 671-675. http://dx.doi.org/10.1089/105072501750362745
Yen, P.M. (2001) Physiological and Molecular Basis of Thyroid Hormone Action. Physiological Reviews, 81, 1097-1142.
Thomas, G.A., Tronko, M.D., Tsyb, A.F. and Tuttle, R.M. (2011) What Have We Learnt from Chernobyl, What Have We Still to Learn. Clinical Oncology, 23, 229-233. http://dx.doi.org/10.1016/j.clon.2011.02.001
United Nations Scientific Committee on the Effects of Atomic Radiation (2011) Sources and effects of Ionizing Radiation, UNSCEAR 2008, Report to the General Assembly with Scientific Annexes, Volume II—Scientific Annexes C, D and E. United Nations Scientific Committee on the Effects of Atomic Radiation, New York.
World Health Organization (1999) Guidelines for Iodine Prophylaxis Following Nuclear Accidents Update 1999. World Health Organization, Geneva.
Wootton, R. and Hammond, B.J. (1978) A Computer Simulation Study of Optimal Thyroid Radiation Protection during Investigations Involving the Administration of Radioiodine-Labelled Pharmaceuticals. British Journal of Radiology, 51, 265-272. http://dx.doi.org/10.1259/0007-1285-51-604-265
Reiners, C. and Schneider, R. (2013) Potassium Iodide (KI) to Block the Thyroid from Exposure to I-131: Current Questions and Answers to Be Discussed. Radiation and Environmental Biophysics, 52, 189-193. http://dx.doi.org/10.1007/s00411-013-0462-0
Schneider, A.B. and Smith, J.M. (2012) Potassium Iodide Prophylaxis: What Have We Learned and Questions Raised by the Accident at the Fukushima Daiichi Nuclear Power Plant. Thyroid, 22, 344-346. http://dx.doi.org/10.1089/thy.2012.2204.com
Lazarus, J.H. (2015) The Importance of Iodine in Public Health. Environmental Geochemistry and Health, 37, 605-618. http://dx.doi.org/10.1007/s10653-015-9681-4
Ohno, S. (1971) Determination of Iodine and Bromine in Biological Materials by Neutron-Activation Analysis. Analyst, 96, 423-426. http://dx.doi.org/10.1039/AN9719600423
Benotti, J., Benotti, N., Pino, S. and Gardyna, H. (1965) Determination of Total Iodine in Urine, Stool, Diets, and Tissue. Clinical Chemistry, 11, 932-936.
Almeida, A.A., Jun, X. and Lima, J.L.F.C. (1997) Ion Chromatographic Determination of Iodide in Urine and Serum Using a Tubular Ion-Selective Electrode Based on a Homogeneous Crystalline Membrane. Mikrochimica Acta, 127, 55-60. https://doi.org/10.1007/BF01243164
Cataldi, T.R.I., Rubino, A., Laviola, M.C. and Ciriello, R. (2005) Comparison of Silver, Gold and Modified Platinum Electrodes for the Electrochemical Detection of Iodide in Urine Samples Following Ion Chromatography. Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences, 827, 224-231. http://dx.doi.org/10.1016/j.jchromb.2005.09.017
Li, H.B., Chen, F. and Xu, X.R. (2001) Determination of Iodide in Seawater and Urine by Size Exclusion Chromatography with Iodine-Starch Complex. Journal of Chromatography A, 918, 335-339. http://dx.doi.org/10.1016/s0021-9673(01)00776-2
Tomiyasu, T., Nonaka, M., Uchikado, M., Anazawa, K. and Sakamoto, H. (2004) Kinetic Determination of Total Iodine in Urine and Foodstuffs Using a Mixed Acid as a Pretreatment Agent. Analytical Sciences, 20, 391-393. https://doi.org/10.2116/analsci.20.391
Burakov, V.S., Isaevich, A.V., Misakov, P.Y., Naumenkov, P.A. and Raikov, S.N. (1994) Intracavity Laser Spectroscopic Method for Determining Trace Amounts of Iodine and Barium in Water and Biological Samples. Journal of Analytical Atomic Spectrometry, 9, 307-309. https://doi.org/10.1039/ja9940900307
Stuewer, D. and Jakubowski, N. (1998) Special Feature: Perspective: Elemental Analysis by Inductively Coupled Plasma Mass Spectrometry with Sector-Field Instruments: A Progress Report. Journal of Mass Spectrometry, 33, 579-590. https://doi.org/10.1002/(SICI)1096-9888(199807)33:7 3.0.CO;2-W
Hou, X. and Roos, P. (2008) Critical Comparison of Radiometric and Mass Spectrometric Methods for the Determination of Radionuclides in Environmental, Biological and Nuclear Waste Samples. Analytica Chimica Acta, 608, 105-139. http://dx.doi.org/10.1016/j.aca.2007.12.012
Allain, P., Mauras, Y., Douge, C., Jaunault, L., Delaporte, T. and Beaugrand, C. (1990) Determination of Iodine and Bromine in Plasma and Urine by Inductively Coupled Plasma Mass Spectrometry. Analyst, 115, 813-815. https://doi.org/10.1039/AN9901500813
Michalke, B., Schramel, P. and Hasse, S. (1996) Determination of Free Iodide in Human Serum: Separation from Other I-Species and Quantification in Serum Pools and Individual Samples. Mikrochimica Acta, 122, 67-76. https://doi.org/10.1007/BF01252407
Radlinger, G. and Heumann, K.G. (1998) Iodine Determination in Food Samples Using Inductively Coupled Plasma Isotope Dilution Mass Spectrometry. Analytical Chemistry, 70, 2221-2224. https://doi.org/10.1021/ac971308k
Haap, M., Roth, H.J., Huber, T., Dittmann, H. and Wahl, R. (2017) Urinary Iodine: Comparison of a Simple Method for Its Determination in Microplates with Measurement by Inductively-Coupled Plasma Mass Spectrometry. Scientific Reports, 7, Article No. 39835. https://doi.org/10.1038/srep39835
Edwin, B.H and Walter, B.G. (1939) Stabilization of Iodine in Salt and Other Feed Materials. US Patent No. 2,144,150.
AFNOR (2009) NF T90-210-Protocole d'évaluation initiale des performances d'une méthode dans un laboratoire. 44 p.
Vanhoe, H., Van Allemeersch, F., Versieck, J. and Dams, R. (1993) Effect of Solvent Type on the Determination of Total Iodine in Milk Powder and Human Serum by Inductively Coupled Plasma Mass Spectrometry. Analyst, 118, 1015-1019. https://doi.org/10.1039/an9931801015
Oliveira, A.A., Trevizan, L.C. and Nóbrega, J.A. (2010) Iodine Determination by Inductively Coupled Plasma Spectrometry. Applied Spectroscopy Reviews, 45, 447-473. https://doi.org/10.1080/05704928.2010.502207
Huynh, D., Zhou, S.J., Gibson, R., Palmer, L. and Muhlhausler, B. (2015) Validation of an Optimized Method for the Determination of Iodine in Human Breast Milk by Inductively Coupled Plasma Mass Spectrometry (ICPMS) after Tetramethylammonium Hydroxide Extraction. Journal of Trace Elements in Medicine and Biology, 29, 75-82. http://dx.doi.org/10.1016/j.jtemb.2014.07.005
Caldwell, K.L., Maxwell, C.B., Makhmudov, A., Pino, S., Braverman, L.E., Jones, R.L., et al. (2003) Use of Inductively Coupled Plasma Mass Spectrometry to Measure Urinary Iodine in NHANES 2000: Comparison with Previous Method. Clinical Chemistry, 49, 1019-1021. https://doi.org/10.1373/49.6.1019
Macours, P., Aubry, J.C., Hauquier, B., Boeynaems, J.M., Goldman, S. and Moreno-Reyes, R. (2008) Determination of Urinary Iodine by Inductively Coupled Plasma Mass Spectrometry. Journal of Trace Elements in Medicine and Biology, 22, 162-165. http://dx.doi.org/10.1016/j.jtemb.2008.02.003
Leggett, R.W. (2010) A Physiological Systems Model for Iodine for Use in Radiation Protection. Radiation Research, 174, 496-516. https://doi.org/10.1667/RR2243.1