Operational Protocol for Detection of Contamination by Actinides U, Pu and Am in Urine Using Calixarene Columns: From Mineralization to ICP-MS Measurement — Oak Academic Publishing
Research ArticleOpen AccessGoogle Scholar indexed
Operational Protocol for Detection of Contamination by Actinides U, Pu and Am in Urine Using Calixarene Columns: From Mineralization to ICP-MS Measurement
Laboratoire de Radiochimie, Service de Dosimétrie Interne, PRP-HOM, Institut de Radioprotection et Sûreté Nucléaire (IRSN), Fontenay-aux-Roses, France
,
Laboratoire de Radiochimie, Service de Dosimétrie Interne, PRP-HOM, Institut de Radioprotection et Sûreté Nucléaire (IRSN), Fontenay-aux-Roses, France
,
Laboratoire de Radiochimie, Service de Dosimétrie Interne, PRP-HOM, Institut de Radioprotection et Sûreté Nucléaire (IRSN), Fontenay-aux-Roses, France
,
Laboratoire de Radiochimie, Service de Dosimétrie Interne, PRP-HOM, Institut de Radioprotection et Sûreté Nucléaire (IRSN), Fontenay-aux-Roses, France
1 Laboratoire de Radiochimie, Service de Dosimétrie Interne, PRP-HOM, Institut de Radioprotection et Sûreté Nucléaire (IRSN), Fontenay-aux-Roses, France
2 Laboratoire de Radiochimie, Service de Dosimétrie Interne, PRP-HOM, Institut de Radioprotection et Sûreté Nucléaire (IRSN), Fontenay-aux-Roses, France
3 Laboratoire de Radiochimie, Service de Dosimétrie Interne, PRP-HOM, Institut de Radioprotection et Sûreté Nucléaire (IRSN), Fontenay-aux-Roses, France
4 Laboratoire de Radiochimie, Service de Dosimétrie Interne, PRP-HOM, Institut de Radioprotection et Sûreté Nucléaire (IRSN), Fontenay-aux-Roses, France
Individual monitoring of workers exposed to the risk of intake of actinides requires suitable methods for measuring low level of excreted activity. The current protocols used for actinides analysis in bioassay are usually complicated and highly time consuming. In this work, a protocol based on the microwave digestion of urines followed by the separation of actinides using calix[6]arene-based chromatography columns and their measurement by a quadrupole ICP-MS is developed and validated, for the first time, on urine samples containing the three actinides, U, Pu and Am. With this protocol, the total analysis time is about 2 days, including the mineralization of urine and the chromatographic separation of actinides. Detection limits of actinides in urine are determined and compared to those obtained after “dilute and shoot” ICP-MS analysis or after alpha spectrometry measurement.
KeywordsActinidesUrineCalix[6]AreneAnalysisICP-MS
Wang, J.J., Chen, I.J. and Chiu, J.H. (2004) Sequential Isotopic Determination of Plutonium, Thorium, Americium, Strontium and Uranium in Environmental and Bioassay Samples. Applied Radiation and Isotopes, 61, 299-305.
Dai, X. and Kramer-Tremblay, S. (2011) An Emergency Bioassay Method for Actinides in Urine. Health Physics, 101, 144-147. https://doi.org/10.1097/HP.0b013e318213d006
Maxwell, S.L. and Culligan, B.K. (2009) Rapid Separation Method for Emergency Water and Urine Samples. Journal of Radioanalytical and Nuclear Chemistry, 279, 901-907. https://doi.org/10.1007/s10967-008-7387-0
Sierra, I. and Hernandez, C. (2016) Development of a Rapid Procedure to Analyse Pu, Am and 90Sr in Emergency Urine Bioassay in Ciemat Bioelimination Laboratory: Method Validation by Emergency Bioassay Intercomparison Exercises. Radiation Protection Dosimetry, 170, 237-241. https://doi.org/10.1093/rpd/ncv519
Boulet, B., Bouvier-Capely, C., Cossonnet, C. and Cote, G. (2006) Solvent Extraction of U(VI) by Calix[6]Arenes. Solvent Extraction and Ion Exchange, 24, 319-330. https://doi.org/10.1080/07366290600646939
Boulet, B., Bouvier-Capely, C., Cote, G., Poriel, L. and Cossonnet, C. (2007) Selective Extraction of Pu(IV) by a Calix[6]Arene Bearing Hydroxamic Groups. Journal of Alloys and Compounds, 444-445, 526-528.
Dinse, C., Baglan, N., Cossonnet, C., Le Du, J.F., Asfari, Z. and Vicens, J. (1998) Solvent Extraction of U(VI) from Media Containing Competing Anions and Metal Cations by a Calix[6]Arene Bearing Carboxy Groups. Journal of Alloys and Compounds, 271-273, 778-781.
Mekki, S., Bouvier-Capely, C., Jalouali, R. and Rebière, F. (2011) The Extraction of Thorium by Calix[6]Arene Columns for Urine Analysis. Radiation Protection Dosimetry, 144, 330-334. https://doi.org/10.1093/rpd/ncq490
Bouvier-Capely, C., Bonthonneau, J.P., Dadache, E. and Rebière, F. (2014) An Alternative Procedure for Uranium Analysis in Drinking Water Using AQUALIX Columns: Application to Varied French Bottled Waters. Talanta, 118, 180-185.
Bouvier-Capely, C., Manoury, A., Legrand, A., Bonthonneau, J.P., Cuenot, F. and Rebière, F. (2009) The Use of Calix[6]Arene Molecules for Actinides Analysis in Urine and Drinking Water: An Alternative to Current Procedures. Journal of Radioanalytical and Nuclear Chemistry, 282, 611-615. https://doi.org/10.1007/s10967-009-0152-1
Poriel, L., Boulet, B., Cossonnet, C. and Bouvier-Capely, C. (2007) Study of the U/Am Separation with Supported Calix[6]Arene in the Aim of Urinary Actinides Analysis. Radiation Protection Dosimetry, 127, 273-276. https://doi.org/10.1093/rpd/ncm281
Baghdadi, S., Cote, G., Beyaert, C., Mane, B., Peroux, A., Masclet, L., et al. (2016) Coupling between a Calix[6]Arene-Based Chromatography Column and ICP-MS for On-Line Actinide Analysis. Journal of Analytical Atomic Spectrometry, 31, 1406-1413. https://doi.org/10.1039/C6JA00063K
Duval, D., Cossonnet, C., Bouvier-Capely, C., Le Strat, C. and Boulet, B. (2006) Chelator, IRSN, French Patent, FR 2006/001105.
Ivanenko, N.B., Ganeev, A.A., Solovyev, N.D. and Moskvin, L.N. (2011) Determination of Trace Elements in Biological Fluids. Journal of Analytical Chemistry, 66, 784-799. https://doi.org/10.1134/S1061934811090036
Kingston, H.M. and Walter, P.J. (1998) The Art and Science of Microwave Sample Preparations for Trace and Ultratrace Elemental Analysis. In: Montaser, A., Ed., Inductively Coupled Mass Spectrometry, Wiley-VCH, New-York, 33-81.
Vajda, N. and Kim, C.K. (2011) Determination of Pu Isotopes by Alpha Spectrometry: A Review of Analytical Methodology. Journal of Radioanalytical and Nuclear Chemistry, 283, 203-223. https://doi.org/10.1007/s10967-009-0342-x
Hummel, W., Anderegg, G., Rao, L., Puigdomenech, I. and Tochiyama, O. (2005) Chemical Thermodynamics of Compounds and Complexes of U, Np, Pu, Am, Tc, Se, Ni and Zr with Selected Organic Ligands. NEA-OECD, Elsevier, Amsterdam.
Bouvier, C., Cote, G., Cierpiszewski, R. and Szymanowski, J. (1998) Influence of the Salting-Out Effects, Temperature and Chemical Structure of the Extractant on the Rate of Copper(II) Extraction from Chloride Media with Dialkyl Pyridine Dicarboxylates. Solvent Extraction & Ion Exchange, 16, 1465-1492. https://doi.org/10.1080/07366299808934590
Bouvier-Capely, C., Ritt, J., Baglan, N. and Cossonnet, C. (2004) Potentialities of Mass Spectrometry (ICP-MS) for Actinides Determination in Urine. Applied Radiation and Isotopes, 60, 629-633. https://doi.org/10.1016/j.apradiso.2004.01.007
Hou, X. and Roos, P. (2008) Critical Comparison of Radiometric and Mass Spectrometric Methods for the Determination of Radionuclides in Environmental, Biological and Nuclear Waste Samples. Analytica Chimica Acta, 608, 105-139. https://doi.org/10.1016/j.aca.2007.12.012
Shi, Y., Dai, X., Li, C., Collins, R., Kramer-Tremblay, S., Riopel, R., et al. (2014) ICP-MS Method for Pu and Np Isotopes in Population Monitoring by a Micro-Flow Injection Sample Introduction System. Journal of Analytical Atomic Spectrometry, 29, 1708-1713. https://doi.org/10.1039/C4JA00105B
Turner, P.J., Mills, D.J., Schroder, E., Lapitajs, G., Jung, G., Iacone, L.A., et al. (1998) Instrumentation for Low- and High-Resolution ICP-MS. In: Montaser, A., Ed., Inductively Coupled Mass Spectrometry, Wiley-VCH, New-York, 485-491.
Zoriy, M.V., Pickhardt, C., Ostapczuk, P., Hille, R. and Becker, J.S. (2004) Determination of Pu in Urine at Ultratrace Level by Sector Field Inductively Coupled Plasma Mass Spectrometry. International Journal of Mass Spectrometry, 232, 217-224.