Development of a Fast and Facile Analytical Approach to Quantify Radiometabolites in Human Plasma Samples Using Ultra High Performance Liquid Chromatography — Oak Academic Publishing
Research ArticleOpen AccessGoogle Scholar indexed
Development of a Fast and Facile Analytical Approach to Quantify Radiometabolites in Human Plasma Samples Using Ultra High Performance Liquid Chromatography
CHRU de Tours, Unité de Radiopharmacie, Tours, France
,
UMR 1253, iBrain, Université de Tours, Inserm, Tours, France
,
Thermo Fisher Scientific, Waltham, MA, USA
,
CHRU de Tours, Service de Médecine Nucléaire in Vitro , Tours, France
,
UMR 1253, iBrain, Université de Tours, Inserm, Tours, France
,
INSERM CIC 1415, University Hospital, Tours, France
1 CHRU de Tours, Unité de Radiopharmacie, Tours, France
2 UMR 1253, iBrain, Université de Tours, Inserm, Tours, France
3 Thermo Fisher Scientific, Waltham, MA, USA
4 CHRU de Tours, Service de Médecine Nucléaire in Vitro , Tours, France
5 UMR 1253, iBrain, Université de Tours, Inserm, Tours, France
6 INSERM CIC 1415, University Hospital, Tours, France
Introduction: Conventional metabolite analyses often require manual sample preparation, generating variability of measurements. This study describes a new method to quantify radiometabolites in blood, combining ultra high performance liquid chromatography (UHPLC) and turbulent flow chromatography, an alternative fully automated process allowing analyte’s extraction. Methods: A new radiotracer for dopamine transporter imaging, namely LBT-999, was used to demonstrate the method’s robustness. Matrix effect, Turboflow column loading, linearity, specificity and precision were evaluated with in vitro samples of LBT-999 in human plasma. Radiodetector sensitivity and preliminary evaluation were respectively determined by analysis of calibrated samples of [ 18 F]LBT-999 and blood samples from 4 healthy subjects injected with [ 18 F]LBT-999, withdrawn at 5, 15, 30 and 45 min pi. Results: With three sequential loadings (3 × 100 μL) of the Turboflow column, mean coefficients of variation were 1%, below 2%, 2% and 30.9% for matrix effect, specificity, repeatability and intermediate precision, respectively. Correlation coefficients for linearity were superior to 0.97. Limits of detection and quantification of the radiodetector were fixed at 3 and 9 c/s. Retention times for [ 18 F]LBT-999 and the two radiometabolites detected by radio-UHPLC were 6.5, 4.8 and 9.6 min. Forty-five min after the injection, parent fraction was still predominant with 57.8% ± 25% of the total radioactivity. Conclusions: An innovative approach, allying UHPLC and Turboflow column, was developed and its sensitivity, linearity, specificity and repeatability validated. Preliminary results of the clinical trial are in accordance with literature data, demonstrating its efficiency in radiometabolites quantification.
KeywordsRadiometaboliteUltra High Performance Liquid ChromatographyTurboflowMethod Validation[<sup>18</sup>F]LBT-999
Mankoff, D.A. (2007) A Definition of Molecular Imaging. Journal of Nuclear Medicine, 48, 18N-21N.
Wu, C., Li, F., Niu, G. and Chen, X. (2013) PET Imaging of Inflammation Biomarkers. Theranostics, 3, 448-466. https://doi.org/10.7150/thno.6592
Meadows, N., Morrison, A., Brindley, D., Schuh, A. and Barker, R. (2015) An Evaluation of Regulatory and Commercial Barriers to Stratified Medicine Development and Adoption. The Pharmacogenomics Journal, 15, 6-12. https://doi.org/10.1038/tpj.2014.51
BertrÁn, M., Martínez, N., Carbajal, G., FernÁndez, A. and Gómez, Á. (2016) An Open Tool for Input Function Estimation and Quantification of Dynamic PET FDG Brain Scans. International Journal of Computer Assisted Radiology and Surgery, 11, 1419-1430. https://doi.org/10.1007/s11548-015-1307-x
Sasaki, T., Ito, H., Kimura, Y., Arakawa, R., Takano, H., Seki, C., et al. (2012) Quantification of Dopamine Transporter in Human Brain Using PET with 18F-FE-PE2I. Journal of Nuclear Medicine, 53, 1065-1073. https://doi.org/10.2967/jnumed.111.101626
Pike, V.W. (2009) PET Radiotracers: Crossing the Blood-Brain Barrier and Surviving Metabolism. Trends in Pharmacological Sciences, 30, 431-440. https://doi.org/10.1016/j.tips.2009.05.005
Lemke, T.L. and Williams, D.A. (2008) Drug Metabolism. In: Foye’s Principles of Medicinal Chemistry. Lippincott Williams & Wilkins, Philadelphia, PA.
Clarke, D. and Sokoloff, L. (1999) Substrates of Cerebral Metabolism. In: Siegel, G.J., Agranoff, B.W., Albers, R.W., Fisher, S.K. and Uhler, M.D., Eds., Basic Neurochemistry: Molecular, Cellular and Medical Aspects, 6th Edition, Lippincott-Raven, Philadelphia, PA. https://www.ncbi.nlm.nih.gov/books/NBK28048/
Rokka, J., Grönroos, T.J., Viljanen, T., Solin, O. and Haaparanta-Solin, M. (2017) HPLC and TLC Methods for Analysis of [18F]FDG and Its Metabolites from Biological Samples. Journal of Chromatography B, 1048, 140-149. https://doi.org/10.1016/j.jchromb.2017.01.042
Collste, K., Forsberg, A., Varrone, A., Amini, N., Aeinehband, S., Yakushev, I., Halldin, C., Farde, L. and Cervenka, S. (2016) Test-Retest Reproducibility of [11C]PBR28 Binding to TSPO in Healthy Control Subjects. European Journal of Nuclear Medicine and Molecular Imaging, 43, 173-183. https://doi.org/10.1007/s00259-015-3149-8
Sérrière, S., Tauber, C., Vercouillie, J., Guilloteau, D., Deloye, J.-B., Garreau, L. and Chalon, S. (2014) In Vivo PET Quantification of the Dopamine Transporter in Rat Brain with [18F]LBT-999. Nuclear Medicine and Biology, 41, 106-113. https://doi.org/10.1016/j.nucmedbio.2013.09.007
Peyronneau, M-A., Saba, W., Dollé, F., Goutal, S., Coulon, C., Bottlaender, M. and Valette, H. (2012) Difficulties in DAT Radioligand PET Analysis: The Example of LBT-999 Using [18F] and [11C] Labelling—Part II. Nuclear Medicine and Biology, 39, 347-359. https://doi.org/10.1016/j.nucmedbio.2011.09.006
Sonawane, L.V., Poul, B.N., Usnale, S.V., Waghmare, P.V. and Surwase, L.H. (2014) Bioanalytical Method Validation and Its Pharmaceutical Application—A Review. Pharmaceutica Analytica Acta, 5. https://doi.org/10.4172/2153-2435.1000288 https://www.omicsonline.org/open-access/bioanalytical-method-validation-and-its-pharmaceutical-application-a-review-2153-2435.1000288.php?aid=25188
Shah, V.P. (2007) The History of Bioanalytical Method Validation and Regulation: Evolution of a Guidance Document on Bioanalytical Methods Validation. The AAPS Journal, 9, E43-E47. https://doi.org/10.1208/aapsj0901005
Varrone, A., Stepanov, V., Nakao, R., Toth, M., Gulyas, B., Emond, P., et al. (2011) Imaging of the Striatal and Extrastriatal Dopamine Transporter with 18F-LBT-999: Quantification, Biodistribution, and Radiation Dosimetry in Nonhuman Primates. Journal of Nuclear Medicine, 52, 1313-1321. https://doi.org/10.2967/jnumed.111.089953
ICH Harmonized Tripartite (2005) Validation of Analytical Procedures: Text and Methodology Q2 R1. https://www.ich.org/fileadmin/Public_Web_Site/ICH_Products/Guidelines/Quality/ Q2_R1/Step4/Q2_R1__Guideline.pdf
Couchman, L. (2012) Turbulent Flow Chromatography in Bioanalysis: A Review. Biomedical Chromatography, 26, 892-905. https://doi.org/10.1002/bmc.2769
Herman, J., Edge, T. and Majors, R. (2012) Theoretical Concepts and Applications of Turbulent Flow Chromatography. Lc Gc North America, 3, 200-214.
Michopoulos, F., Edge, A.M., Theodoridis, G. and Wilson, I.D. (2010) Application of Turbulent Flow Chromatography to the Metabonomic Analysis of Human Plasma: Comparison with Protein Precipitation. Journal of Separation Science, 33, 1472-1479. https://doi.org/10.1002/jssc.200900789
Liesener, A. and Karst, U. (2005) Turbulent Flow Chromatography for the Reduction of Matrix Effects in Electrospray Ionization Mass Spectrometry-Based Enzyme Assays. Journal of Separation Science, 28, 1658-1665. https://doi.org/10.1002/jssc.200500090
Du, L. and White, R.L. (2008) Reducing Glycerophosphocholine Lipid Matrix Interference Effects in Biological Fluid Assays by Using High-Turbulence Liquid Chromatography. Rapid Communications in Mass Spectrometry, 22, 3362-3370. https://doi.org/10.1002/rcm.3747
He, X. and Kozak, M. (2012) Development of a Liquid Chromatography Tandem Mass Spectrometry Method for Plasma-Free Metanephrines with Ion-Pairing Turbulent Flow Online Extraction. Analytical and Bioanalytical Chemistry, 402, 3003-3010. https://doi.org/10.1007/s00216-012-5768-2
Bourgogne, E., Soichot, M., Latour, C. and Laprévote, O. (2013) Rugged and Accurate Quantitation of Colchicine in Human Plasma to Support Colchicine Poisoning Monitoring by Using Turbulent-Flow LC—MS/MS Analysis. Bioanalysis, 5, 2889-2896. https://doi.org/10.4155/bio.13.258
Polson, C., Sarkar, P., Incledon, B., Raguvaran, V. and Grant, R. (2003) Optimization of Protein Precipitation Based upon Effectiveness of Protein Removal and Ionization Effect in Liquid Chromatography—Tandem Mass Spectrometry. Journal of Chromatography B, 785, 263-275. https://doi.org/10.1016/S1570-0232(02)00914-5
Annesley, T.M. and Clayton, L. (2004) Simple Extraction Protocol for Analysis of Immunosuppressant Drugs in Whole Blood. Clinical Chemistry, 50, 1845-1848. https://doi.org/10.1373/clinchem.2004.037416
Xie, X., Carrell, T. and Kozak, M. (2016) Quantitation of THC and THC Metabolites in Blood Using SOLAμ SPE Plates and the TSQ Quantiva Triple Quadrupole Mass Spectrometer for Forensic Analysis. Thermo Fisher Scientific, 657, 1-6.
Nakao, R., Schou, M. and Halldin, C. (2012) Rapid and Sensitive Measurement of PET Radioligands in Plasma by Fast Liquid Chromatography/Radiometric Detection. Journal of Chromatography B, 895-896, 116-122. https://doi.org/10.1016/j.jchromb.2012.03.028
Nakao, R., Schou, M. and Halldin, C. (2012) Rapid Metabolite Analysis of Positron Emission Tomography Radioligands by Direct Plasma Injection Combining Micellar Cleanup with High Submicellar Liquid Chromatography with Radiometric Detection. Journal of Chromatography A, 1266, 76-83. https://doi.org/10.1016/j.chroma.2012.10.022
Saba, W., Peyronneau, M.-A., Dollé, F., Goutal, S., Bottlaender, M. and Valette, H. (2012) Difficulties in DAT Radioligand PET Analysis: LBT-999 Using [18F] and [11C] Labelling—Part I. Nuclear Medicine and Biology, 39, 227-233. https://doi.org/10.1016/j.nucmedbio.2011.08.003
Schou, M., Steiger, C., Varrone, A., Guilloteau, D. and Halldin, C. (2009) Synthesis, Radiolabeling and Preliminary in Vivo Evaluation of [18F]FE-PE2I, a New Probe for the Dopamine Transporter. Bioorganic & Medicinal Chemistry Letters, 19, 4843-4845. https://doi.org/10.1016/j.bmcl.2009.06.032
Zoghbi, S.S., Shetty, H., Ichise, M., Fujita, M., Imaizumi, M., Liow, J.S., et al. (2006) PET Imaging of the DAT with 18F-FECNT: A Polar Radiometabolite Confounds Brain Radioligand Measurements. Journal of Nuclear Medicine, 47, 520-527.
Shetty, H.U., Zoghbi, S.S., Liow, J.-S., Ichise, M., Hong, J., Musachio, J.L., et al. (2007) Identification and Regional Distribution in Rat Brain of Radiometabolites of the Dopamine Transporter PET Radioligand [11C]PE2I. European Journal of Nuclear Medicine and Molecular Imaging, 34, 667-678. https://doi.org/10.1007/s00259-006-0277-1
Hirvonen, J., Johansson, J., Teräs, M., Oikonen, V., Lumme, V., Virsu, P., et al. (2008) Measurement of Striatal and Extrastriatal Dopamine Transporter Binding with High-Resolution PET and [11C]PE2I: Quantitative Modeling and Test—Retest Reproducibility. Journal of Cerebral Blood Flow & Metabolism, 28, 1059-1069. https://doi.org/10.1038/sj.jcbfm.9600607
Jucaite, A., Odano, I., Olsson, H., Pauli, S., Halldin, C. and Farde, L. (2006) Quantitative Analyses of Regional [11C]PE2I Binding to the Dopamine Transporter in the Human Brain: A PET Study. European Journal of Nuclear Medicine and Molecular Imaging, 33, 657-668. https://doi.org/10.1007/s00259-005-0027-9
Fazio, P., Svenningsson, P., Forsberg, A., Jonsson, E.G., Amini, N., Nakao, R., et al. (2015) Quantitative Analysis of 18F-(E)-N-(3-Iodoprop-2-Enyl)-2β-Carbofluoroe- thoxy-3β-(4’-Methyl-Phenyl) Nortropane Binding to the Dopamine Transporter in Parkinson Disease. Journal of Nuclear Medicine, 56, 714-720. https://doi.org/10.2967/jnumed.114.152421
Amini, N., Nakao, R., Schou, M. and Halldin, C. (2013) Identification of PET Radiometabolites by Cytochrome P450, UHPLC/Q-ToF-MS and Fast Radio-LC: Applied to the PET Radioligands [11C]Flumazenil, [18F]FE-PE2I, and [11C]PBR28. Analytical and Bioanalytical Chemistry, 405, 1303-1310. https://doi.org/10.1007/s00216-012-6541-2
Varrone, A., Tóth, M., Steiger, C., Takano, A., Guilloteau, D., Ichise, M., et al. (2011) Kinetic Analysis and Quantification of the Dopamine Transporter in the Nonhuman Primate Brain with 11C-PE2I and 18F-FE-PE2I. Journal of Nuclear Medicine, 52, 132-139. https://doi.org/10.2967/jnumed.110.077651
De Graaf, I.A.M., Van Meijeren, C.E., Pektaş, F. and Koster, H.J. (2002) Comparison of in Vitro Preparations for Semi-Quantitative Prediction of in Vivo Drug Metabolism. Drug Metabolism & Disposition, 30, 1129-1136. https://doi.org/10.1124/dmd.30.10.1129