New Analytical Methodology for Sb(III) Traces Quantification as Emergent Contaminant in Drinks Packaged PET Samples by Solid Surface Fluorescence — Oak Academic Publishing
Research ArticleOpen AccessGoogle Scholar indexed
New Analytical Methodology for Sb(III) Traces Quantification as Emergent Contaminant in Drinks Packaged PET Samples by Solid Surface Fluorescence
Instituto de Química de San Luis (INQUISAL-CONICET), Chacabuco y Pedernera, San Luis, Argentina
,
Instituto de Química de San Luis (INQUISAL-CONICET), Chacabuco y Pedernera, San Luis, Argentina
,
Instituto de Química de San Luis (INQUISAL-CONICET), Chacabuco y Pedernera, San Luis, Argentina
,
Instituto de Química de San Luis (INQUISAL-CONICET), Chacabuco y Pedernera, San Luis, Argentina
,
Área de Química Analítica, Facultad de Química, Bioquímica y Farmacia, UNSL, San Luis, Argentina
1 Instituto de Química de San Luis (INQUISAL-CONICET), Chacabuco y Pedernera, San Luis, Argentina
2 Instituto de Química de San Luis (INQUISAL-CONICET), Chacabuco y Pedernera, San Luis, Argentina
3 Instituto de Química de San Luis (INQUISAL-CONICET), Chacabuco y Pedernera, San Luis, Argentina
4 Instituto de Química de San Luis (INQUISAL-CONICET), Chacabuco y Pedernera, San Luis, Argentina
5 Área de Química Analítica, Facultad de Química, Bioquímica y Farmacia, UNSL, San Luis, Argentina
Emerging contaminants constitute a set of substances that are released into the environment for which regulations are currently not established for their environmental monitoring, being antimony one of them. A new methodology for Sb(III) traces monitoring by solid surface fluorescence is proposed. The metal was complexed with alizarine (Az) as fluorosphore reagent in alcaline medium in presence of the bile salt sodium cholate. To isolate the analyte of matrix constituents, a preconcentration/separation strategy on filter paper was introduced prior to determination step. The solid surface fluorescence was measured λ em = 450 nm and λ exc = 363 nm using a solid sampler holder. Under optimal conditions, the limits of detection and quantification of proposed methodology were 0.08 and 0.24 μg·L -1 , respectively, showing a linear range from 0.24 to 304.4 μg·L -1 with good sensitivity and adequate selectivity. It was applied to the Sb(III) traces determination present in drinking water and beverages samples packaged in polyethylene terephthalate (PET) bottles widely consumed in Argentina. The combination of a preconcentration step on common filter paper and the inherent sensitivity of photoluminescent methods have permitted to achieve sensitivity similar to atomic spectroscopies using a lower price instrument typical in control laboratories. Precision and accuracy were tested with excellent agreement. Results were truenessed by ETAAS with satisfactory concordance.
KeywordsEmerging ContaminantsAntimony TracesAlizarineSolid Surface FluorescenceWaters and Beverages
Wilson & Wilson’s (1996) Comprehensive Analytical Chemistry. In: Pramauro, E. and Pelizzetti, E., Eds., Surfactants in Analytical Chemistry: Applications of Organized Amphiphilic Media, Elsevier, Amsterdam, Volume 31, Chapter 4.
Luconi, M., Olsina, R., FernÁndez, L. and Silva, M. (2006) Determination of Lead in Human Saliva by Combined Cloud Point Extraction-Capillary Zone Electrophoresis with Indirect UV Detection. Journal of Hazardous Materials, 128, 240-246. https://doi.org/10.1016/j.jhazmat.2005.08.007
Talio, M., Luconi, M., Masi, A. and FernÁndez, L. (2009) Determination of Cadmium at Ultratrace Levels by CPE-Molecular Fluorescence Combined Methodology. Journal of Hazardous Materials, 170, 272-277. https://doi.org/10.1016/j.jhazmat.2009.04.101
Watanabe, H. and Tanaka, H. (1978) A Non-Ionic Surfactant as a New Solvent for Liquid-Liquid Extraction of Zinc(II) with 1-(2-pyridylazo)-2-naphthol. Talanta, 25, 585-589. https://doi.org/10.1016/0039-9140(78)80151-9
Jia, G., Li, L., Qiu, J., Wang, X., Zhu, W., Sun, Y. and Zhou, Z. (2007) Determination of Carbaryl and Its Metabolite 1-Naphthol in Water Samples by Fluorescence Spectrophotometer after Anionic Surfactant Micelle-Mediated Extraction with Sodium Dodecylsulfate. Spectrochimica Acta Part A, 67, 460-464. https://doi.org/10.1016/j.saa.2006.08.003
Sosa Ferrera, Z., Padron Sanz, C., Mahugo Santana, C. and Santana Rodríguez, J.J. (2004) The Use of Micellar Systems in the Extraction and Pre-Concentration of Organic Pollutans in the Environmental Samples. Trends in Analytical Chemistry, 23, 469-479. https://doi.org/10.1016/S0165-9936(04)00732-0
Talio, M.C., Luconi, M., Masi, A. and FernÁndez, L. (2010) Cadmium Monitoring in Saliva and Urine as Indicator of Smoking Addiction. Science of the Total Environment, 408, 3125-3132. https://doi.org/10.1016/j.scitotenv.2010.03.052
Karbasia, M., Jahanparast, B., Shamsipur, M. and Hassan, J. (2009) Simultaneous Tracemultielement Determination by ICP-OES after Solid Phase Extraction with Modified Octadecyl Silica Gel. Journal of Hazardous Materials, 170, 151-155. https://doi.org/10.1016/j.jhazmat.2009.04.119
Juleiman, S., Hu, B., Huang, C. and Zhang, N. (2008) Determination of Cd Co, Ni and Pb in Biological Samples by Microcolumn Packed with Black Stone (Pierre Noire) Online Coupled with ICP-OES. Journal of Hazardous Materials, 157, 410-417. https://doi.org/10.1016/j.jhazmat.2008.01.014
Peralta, C., FernÁndez, L. and Masi, A. (2010) A Novel Application of Immobilization on Membranes for the Separation and Spectrofluorimetric Quantification of Amiloride and Furosemide in Pharmaceutical Samples. Analytica Chimica Acta, 661, 85-90. https://doi.org/10.1016/j.aca.2009.12.015
Thomaidis, N.S., Asimakopoulos, A.G. and Bletsou, A.A. (2012) Emerging Contaminants: A Tutorial Mini-Review. Global NEST Journal, 14, 72-79. https://doi.org/10.30955/gnj.000823
Richardson, S.D. (2010) Environmental Mass Spectrometry: Emerging Contaminants and Current Issues. Analytical Chemistry, 82, 4742-4774. https://doi.org/10.1021/ac101102d
Bach, C., Dauchy, X., Chagnon, M.C. and Etienne, S. (2012) Chemical Compounds and Toxicological Assessments of Drinking Water Stored in Polyethylene Terephthalate (PET) Bottles: A Source of Controversy Reviewed. Water Research, 46, 571-583. https://doi.org/10.1016/j.watres.2011.11.062
Westerhoff, P., Prapaipong, P., Shock, E. and Hillaireau, A. (2008) Antimony Leaching from Polyethylene Terephthalate (PET) Plastic Used for Bottled Drinking Water. Water Research, 42, 551-556. https://doi.org/10.1016/j.watres.2007.07.048
Welle, F. and Franz, R. (2011) Migration of Antimony from PET Bottles into Beverages: Determination of the Activation Energy of Diffusion and Migration Modelling Compared with Literature Data. Food Additives & Contaminants Part A, 28, 115-126. https://doi.org/10.1080/19440049.2010.530296
Richardson, S.D. and Ternes, T.A. (2011) Water Analysis: Emerging Contaminants and Current Issues. Analytical Chemistry, 83, 4614-4648. https://doi.org/10.1021/ac200915r
Sundar, S. and Chakravarty, J. (2010) Antimony Toxicity. International Journal of Environmental Research and Public Health, 7, 4267-4277. https://doi.org/10.3390/ijerph7124267
Biata, N.R., Nyaba, L., Ramontja, J., Mketo, N. and Nomngongo, P.N. (2017) Determination of Antimony and Tin in Beverages Using Inductively Coupled Plasma-Optical Emission Spectrometry after Ultrasound-Assisted Ionic Liquid Dispersive Liquid-Liquid Phase Microextraction. Food Chemistry, 237, 904-911. https://doi.org/10.1016/j.foodchem.2017.06.058
De Moraes Flores, É.M., Pereira dos Santos, E., SmaniotoBarin, J., Zanella, R., Luiz Dressler, V. and Figueiredo Bittencourt, C. (2002) Determination of Antimony (III) and Total Antimony by Hydride Generation Atomic Absorption Spectrometry in Samples of Injectable Drugs Used for Leishmaniasis Treatment. Journal of Analytical Atomic Spectrometry, 17, 819-823. https://doi.org/10.1039/b203166c
Cardozo, M.C., Cavalcante, D.D., Silva, D.L.F., Do Santos, W.N.L. and Bezerra, M.A. (2016) Multivariate Optimization of a Method for Antimony Determination by Hydride Generation Atomic Fluorescence Spectrometry in Hair Samples of Patients Undergoing Chemotherapy against Leishmaniasis. Anais da Academia Brasileira de Ciências Academia Brasileira de Ciências, 88, 1179-1190. https://doi.org/10.1590/0001-3765201620150250
Filatova, D.G., Zhukova, A.A. and Podol’ko, E.V. (2012) Determination of Antimony and Tin in Tin Dioxide Whiskers by Inductively Coupled Plasma Mass Spectrometry. Journal of Analytical Chemistry, 67, 950-954. https://doi.org/10.1134/S1061934812100036
Dos Santos, G.S., Silva, L.O.B., Santos Júnior, A.F., da Silva, E.G.P. and dos Santos, W.N.L. (2018) Determination and Environmental Impact Assessment of Inorganic Antimony Species in Natural Waters Using Hydride Generation Atomic Fluorescence Spectrometry (HG AFS). Journal of the Brazilian Chemical Society, 29, 185-190. https://doi.org/10.21577/0103-5053.20170129
Talio, M.C., Acosta, M.G., Acosta, M., Olsina, R. and FernÁndez, L.P. (2015) Novel Method for Determination of Zinc Traces in Beverages and Water Samples by Solid Surface Fluorescence Using a Conventional Quartz Cuvette. Food Chemistry, 175, 151-156. https://doi.org/10.1016/j.foodchem.2014.11.082
Talio, M.C., Kaplan, M., Acosta, M., Gil, R.A., Luconi, M.O. and FernÁndez, L.P. (2015) New Room Temperature Coacervation Scheme for Lead Traces Determination by Solid Surface Fluorescence. Application to Wines Produced in Argentina. Microchemical Journal, 123, 237-242. https://doi.org/10.1016/j.microc.2015.06.014
Andra, S.S., Makris, K.C., Shine, J.P. and Lu, C. (2012) Co-Leaching of Brominated Compounds and Antimony from Bottled Water. Environment International, 38, 45-53. https://doi.org/10.1016/j.envint.2011.08.007
Kunkely, H. and Vogle, A. (2007) Fluorescence of Alizarin Complexone and Its Metal Complexes. Inorganic Chemistry Communications, 10, 355-357. https://doi.org/10.1016/j.inoche.2006.11.020
Sun, C., Li, Y., Qi, D., Li, H. and Song, P. (2016) Optical and Electrical Properties of Purpurin and Alizarin Complexone as Sensitizers for Dye-Sensitized Solar Cells. Journal of Materials Science: Materials in Electronics, 27, 8027-8039. https://doi.org/10.1007/s10854-016-4799-4
Acosta, M.G., Talio, M.C., Luconi, M.O., Hinze, W.L. and FernÁndez, L.P. (2014) Fluorescence Method Using On-Line Sodium Cholatecoacervate Surfactant Mediated Extraction for the Flow Injections Analysis of Rhodamine B. Talanta, 129, 516-522. https://doi.org/10.1016/j.talanta.2014.06.014
Hinze, W.L. (2000) Bile Acid/Salts Surfactant Systems. Second Edition, JAI Press, Stamford.
McGown, L.B., Meyerhoffer, S., Hertz, P. and Li, G. (2000) Luminescence Measurements in Bile Salt Micelles. In: Hinze, W., Ed., Bile Acid/Salt Surfactant Systems, Organized Assemblies in Chemical Analysis, JAI Press, Stamford, 167-186.
Gupta, V.B. and Shrivastava, A. (2011) Methods for the Determination of Limit of Detection and Limit of Quantitation of the Analytical Methods. Chronicles of Young Scientists, 2, 21-25. https://doi.org/10.4103/2229-5186.79345
Richardson, S.D. and Ternes, T.A. (2014) Water Analysis: Emerging Contaminants and Current Issues. Analytical Chemistry, 86, 2813-2848. https://doi.org/10.1021/ac500508t