Effect of Depth-Dependent Nociceptor Density on the Heat-Induced Withdrawal Reflex
- 1 Department of Applied Mathematics, University of California, Santa Cruz, CA, USA
- 2 U.S. Department of Defense, Joint Intermediate Force Capabilities Office, Quantico, VA, USA
- 3 Department of Applied Mathematics, Naval Postgraduate School, Monterey, CA, USA
Abstract
Previously we introduced a concise dose-response model for the heat-induced withdrawal reflex caused by millimeter wave radiation. The model predicts the occurrence of withdrawal reflex from the given spatial temperature profile. It was formulated on the assumption that the density of nociceptors in skin is uniform, independent of the depth. The model has only two parameters: the activation temperature of heat-sensitive nociceptors and the critical threshold on the activated volume for triggering withdrawal reflex. In this study, we consider the case of depth-dependent nociceptor density in skin. We use a general parametric form with a scaling parameter in the depth direction to represent the nociceptor density. We analyze system behaviors for four density types of this form. Based on the theoretical results, we develop a methodology for 1) identifying from test data the density form of nociceptors distribution, 2) finding from test data the scaling parameter in the density form, and 3) determining from test data the activation temperature of nociceptors.
- Gandhi, O.P. and Riazi, A. (1986) Absorption of Millimeter Waves by Human Beings and Its Biological Implications. IEEE Transactions on Microwave Theory and Techniques, 34, 228-235. https://doi.org/10.1109/TMTT.1986.1133316
- Romanenko, S., Begley, R., Harvey, A.R., Hool, L. and Wallace, V.P. (2017) The Interaction between Electromagnetic Fields at Megahertz, Gigahertz and Terahertz Frequencies with Cells, Tissues and Organisms: Risks and Potential. Journal of The Royal Society Interface, 14, Article ID: 20170585. https://doi.org/10.1098/rsif.2017.0585
- Zhadobov, M., Chahat, N., Sauleau, R., Le Quement, C. and Le Drean, Y. (2011) Millimeter-Wave Interactions with the Human Body: State of Knowledge and Recent Advances. International Journal of Microwave and Wireless Technologies, 3, 237-247. https://doi.org/10.1017/S1759078711000122
- Foster, K.R., Ziskin, M.C. and Balzano, Q. (2016) Thermal Response of Human Skin to Microwave Energy: A Critical Review. Health Physics, 111, 528-541. https://doi.org/10.1097/HP.0000000000000571
- Ozen, S., Helhel, S. and Bilgin, S. (2011) Temperature and Burn Injury Prediction of Human Skin Exposed to Microwaves: A Model Analysis. Radiation and Environmental Biophysics, 50, 483-489. https://doi.org/10.1007/s00411-011-0364-y
- Nelson, D.A., Nelson, M.T., Walters, T.J. and Mason, P.A. (2000) Skin Heating Effects of Millimeter-Wave Irradiation—Thermal Modeling Results. IEEE Transactions on Microwave Theory and Techniques, 48, 2111-2120. https://doi.org/10.1109/22.884202
- Laakso, I., Morimoto, R., Heinonen, J., Jokela, K. and Hirata, A. (2017) Human Exposure to Pulsed Fields in the Frequency Range from 6 to 100 GHz. Physics in Medicine & Biology, 62, 6980-6992. https://doi.org/10.1088/1361-6560/aa81fe
- Durney, C.H., Massoudi, H. and Iskander, M.F. (1986) Radiofrequency Radiation Dosimetry Handbook. 4th Edition, Brooks AFB, TX: USAF School Aerospace Med.
- Xu, F. and Lu, T. (2011) Introduction to Skin Biothermomechanics and Thermal Pain. Springer, New York. https://doi.org/10.1007/978-3-642-13202-5
- Gabriel, S., Lau, R.W. and Gabriel, C. (1996) The Dielectric Properties of Biological Tissues: II Measurements in the Frequency Range 10 Hz to 20 GHz. Physics in Medicine and Biology, 41, 2251-2269. https://doi.org/10.1088/0031-9155/41/11/002
- Hwang, H., Yim, J., Cho, J.-W., Cheon, C. and Kwon, Y. (2003) 110 GHz Broadband Measurement of Permittivity on Human Epidermis Using 1 mm Coaxial Probe. International Microwave Symposium Digest, 1, 399-402.