Appropriate Placement of Fault Current Limiting Reactors in Different HV Substation Arrangements
Faculty of Electrical and Computer Engineering, University of Tabriz, Tabriz, Iran
Faculty of Electrical and Computer Engineering, University of Tabriz, Tabriz, Iran
- 1 Faculty of Electrical and Computer Engineering, University of Tabriz, Tabriz, Iran
- 2 Faculty of Electrical and Computer Engineering, University of Tabriz, Tabriz, Iran
Copy link · social · email
Abstract
Short circuit currents of power systems are growing with an increasing rate, due to the fast development of generation and transmission systems. Current Limiting Reactor is one of the effective short circuit current limiting devices. This technique is known to be more practical than other available approaches. In this paper, proper application of CLR to HV substations is proposed, based on a comprehensive short circuit analysis of 4 well-known substation bus bar arrangements. Eventually, appropriate place and number of CLRs is recommended for each bus bar arrangement.
KeywordsCurrent Limiting ReactorFault Current LimiterBus Arrangement
- J. F. Amon, P. C. Fernandez, E. H. Rose, A. D′Ajuz and A. Castanheira, “Brazilian Successful Experience in the Usage of Current Limiting Reactors for Short-Circuit Limitation,” International Conference on Power Systems Transients (IPST’05), Montreal, 19-23 June 2005, pp. 215-220.
- Z.-X. Geng, X. Lin, J.-Y. Xu and C. Tian, “Effects of Series Reactor on Short-circuit Current and Transient Recovery Voltage,” 2008 International Conference on High Voltage Engineering and Application, Chongqing, 9-13 November 2008, pp. 524-526.
- M. Gilany and W. Al-Hasawi, “Reducing the Short Circuit Levels in Kuwait Transmission Network (A Case Study),” World Academy of Science, Engineering and Technology, Vol. 53, 2009, pp. 592-596.
- A. Nasiri and H. Barahmandpour, “Fault Current Limitation of Ramin Power Plant,” 21st International Power System Conference (PSC), Tehran, 2006, pp. 1640-1646.
- T. Roininen, C. E. Solver, H. Nordli, A. Bosma, P. Jonsson and A. Alfredsson, “ABB Live Tank Circuit Breakers, Application Guide.” www.abb.com
- D. F. Peelo, G. S. Polovick, J. H. Sawada, P. Diamanti, R. Presta, A. Sarshar and R. Beauchemin, “Mitigation of Circuit Breaker Transient Recovery Voltages Associated with Current Limiting Reactors,” IEEE Transactions on Power Delivery, Vol. 11, No. 2, 1996, pp. 865-871. doi:10.1109/61.489345
- M. Khorrami, M. S. Nader and N. K. Nejhad, “Short Circuit Current Level Control and Its Effects on Circuit Breakers Transient Studies,” Journal of Electrical Engineering: Theory and Application, Vol. 1, No. 1, 2010, pp. 4-17.
- M. M. R. Ahmed, G. A. Putrus, R. Li and L. J. Xiao, “Harmonic Analysis and Improvement of a New SolidState Fault Current Limiter,” IEEE Transactions on Industry Applications, Vol. 40, No. 4, 2004, pp. 1012-1019. doi:10.1109/TIA.2004.830774
- G. G. Karady, “Principles of Fault Current Limitation by a Resonant LC Circuit,” IEE Proceedings-C, Vol. 139, No. 1, 1992, pp. 1-6.
- B. W. Lee, J. Sim, K. B. Park and I. S. Oh, “Practical Application Issues of Superconducting Fault Current Limiters for Electric Power Systems,” IEEE Transactions on Applied Superconductivity, Vol. 18, No. 2, 2008, pp. 620-623. doi:10.1109/TASC.2008.920784
- Y. Lin, M. Majoros, T. Coombs and A. M. Campbell, “System Studies of the Superconducting Fault Current Limiter in Electrical Distribution Grids,” IEEE Transactions on Applied Superconductivity, Vol. 17, No. 2, 2007, pp. 2339-2342. doi:10.1109/TASC.2007.900988