A Novel Flower Pollination Algorithm to Solve Load Frequency Control for a Hydro-Thermal Deregulated Power System
- 1 Department of Electrical and Electronics Engineering, Sree Sastha Institute of Engineering and Technology, Chennai, India
- 2 School of Electrical Engineering, Vellore Institute of Technology, Chennai, India
- 3 Department of Electrical and Electronics Engineering, SSN College of Engineering, Kalavakam, Chennai, India
Abstract
Load frequency control plays a vital role in power system operation and control. LFC regulates the frequency of larger interconnected power systems and keeps the net interchange of power between the pool members at predetermined values for the corresponding changes in load demand. In this paper, the two-area, hydrothermal deregulated power system is considered with Redox Flow Batteries (RFB) in both the areas. RFB is an energy storage device, which converts electrical energy into chemical energy, that is used to meet the sudden requirement of real power load and hence very effective in reducing the peak shoots. With conventional proportional-integral (PI) controller, it is difficult to get the optimum solution. Hence, intelligent techniques are used to tune the PI controller of the LFC to improve the dynamic response. In the family of intelligent techniques, a recent nature inspired algorithm called the Flower Pollination Algorithm (FPA) gives the global minima solution. The optimal value of the controller is determined by minimizing the ISE. The results show that the proposed FPA tuned PI controller improves the dynamic response of the deregulated system faster than the PI controller for different cases. The simulation is implemented in MATLAB environment.
- Elgerd, O.I. (1982) Electric Energy Systems Theory: An Introduction.
- Report, I.C. (1973) Dynamic Models for Steam and Hydro Turbines in Power System Studies. IEEE Transactions on Power Apparatus and Systems, PAS-92, 1904-1915. http://dx.doi.org/10.1109/TPAS.1973.293570
- Demello, F., Koessler, R.J., Agee, J., Anderson, P.M., Doudna, J.H., Fish, J.H. and Taylor, C. (1992) Hydraulic-Turbine and Turbine Control-Models for System Dynamic Studies. IEEE Transactions on Power Systems, 7, 167-179. http://dx.doi.org/10.1109/59.141700
- Christie, R.D. and Bose, A. (1996) Load Frequency Control Issues in Power System Operations after derEgulation. IEEE Transactions on Power Systems, 11, 1191-1200. http://dx.doi.org/10.1109/59.535590
- Fathima, A.P. and Khan, M.A. (2008) Design of a New Market Structure and Robust Controller for the Frequency Regulation Service in the Deregulated Power System. Electric Power Components and Systems, 36, 864-883. http://dx.doi.org/10.1080/15325000801911443
- Donde, V., Pai, M.A. and Hiskens, I.A. (2001) Simulation and Optimization in an AGC System after Deregulation. IEEE Transactions on Power Systems, 16, 481-489. http://dx.doi.org/10.1109/59.932285
- Ziegler, J.G. and Nichols, N.B. (1942) Optimum Settings for Automatic Controllers. Transactions of the ASME, 64, 759-768.
- Gopal, M. (2002) Control Systems: Principles and Design. Tata McGraw-Hill Education, Noida.
- Aditya, S.K. and Das, D. (2001) Battery Energy Storage for Load Frequency Control of an Interconnected Power System. Electric Power Systems Research, 58, 179-185. http://dx.doi.org/10.1016/S0378-7796(01)00129-8
- Chidambaram, I.A. and Paramasivam, B. (2013) Optimized Load-Frequency Simulation in Restructured Power System with Redox Flow Batteries and Interline Power Flow Controller. International Journal of Electrical Power & Energy Systems, 50, 9-24. http://dx.doi.org/10.1016/j.ijepes.2013.02.004
- Chandrakala, V., Sukumar, B. and Sankaranarayanan, K. (2014) Load Frequency Control of Multi-Source Multi-Area Hydro Thermal System Using Flexible Alternating Current Transmission System Devices. Electric Power Components and Systems, 42, 927-934. http://dx.doi.org/10.1080/15325008.2014.903540
- Weber, A.Z., Mench, M.M., Meyers, J.P., Ross, P.N., Gostick, J.T. and Liu, Q. (2011) Redox Flow Batteries: A Review. Journal of Applied Electrochemistry, 41, 1137-1164. http://dx.doi.org/10.1007/s10800-011-0348-2