<i>In-Situ</i> Domestic Load Harmonic Detection and Reduction Based on GLRM Algorithm for Optimum Filter Excerpt
- 1 Department of Electrical and Electronics Engineering, Vel Tech Engineering College, Anna University, Chennai, India
- 2 Department of Electrical and Electronics, Engineering, R. M. K. C. E. T, Anna University, Chennai, India
- 3 Department of Electrical and Electronics Engineering, Vel Tech Engineering College, Anna University, Chennai, India
Abstract
Power Quality measures the reliable operation between the system and to the connected loads of same system. A poor power quality causes physical damage to the equipment and also results in lower productivity with increase in energy costs. Power disturbances range from micro seconds to hours and the prolonged disturbances in hours would damage the equipments. The power quality decreases due to growth of nonlinear loads in domestic appliances, such as home Uninterrupted Power Supplies (UPS), Induction stove, Television etc. Nowadays Domestic loads are controlled or powered with power electronic devices. The power electronic devices with Direct Current (DC) components generate high frequency signal for DC-Alternating Current (AC) conversion. The conversion introduces multiple frequencies in the AC power supply. The multiple frequencies in AC power supply are called as harmonics. The harmonics in AC supply affects the lifetime of home appliances, consumes more electric current, affects the power factor, transformer efficiency, and other electricity supply systems. Till now, to avoid harmonics, the filters are erected only in industrial loads or in the substations. In this paper a novel method to detect and control harmonics in domestic appliances is proposed. Harmonic control with various filters in the filter bank, based on detection of harmonic voltage let out from the domestic appliances for power saving. To select the appropriate filter to improve power quality, we apply a novel Genetic Algorithm based Linear Regression Method (GLRM) algorithm for optimum Filter Selection. From the results we were able to reduce the total harmonic distortion level to 3.68%.The current consumption of each household appliance is reduced considerably and finally the electricity bill is reduced to 15% and overall system efficiency improves to 85%.
- Tuyen, N.D. and Fujita, G. (2015) PV-Active Power Filter Combination Supplies Power to Nonlinear Load and Compensates Utility Current. IEEE Power and Energy Technology Systems Journal, 2, 32-42.
- Bagheri, P., Xu, W. and Ding, T. (2015) A Distributed Filtering Scheme to Mitigate Harmonics in Residential Distribution Systems. IEEE Transactions on Power Delivery, 31, 648-656.
- Rq, H. and Hyho, H. (2012) Evaluation the Long-Term Impact of a Continuously Increasing Harmonic Load Demand on Feeder Level Voltage Distortion. IEEE, 8, 1-8.
- Bagheri, P. and Xu, W. (2014) A Technique to Mitigate Zero-Sequence Harmonics in Power Distribution Systems. IEEE Transactions on Power Delivery, 29, 215-223. http://dx.doi.org/10.1109/tpwrd.2013.2291866
- Pinceti, P. and Prando, D. (2015) Sensitivity of Parallel Harmonic Filters to Parameters Variations. International Journal of Electrical Power & Energy Systems, 68, 26-32. http://dx.doi.org/10.1016/j.ijepes.2014.12.030
- Schofield, N. (2015) Shunt Active Power Filtering for Smart Appliances. Proceeding of the IEEE 28th Canadian Conference on Electrical and Computer Engineering, Halifax, 3-6 May 2015, 466-470.
- Todeschini, G., Mueller, D.R. and Morris, G.Y. (2013) Telephone Interference Caused by Harmonics in Distribution Systems?: Analysis and Simulations. IEEE Power & Energy Society General Meeting, Vancouver, 21-25 July 2013, 1-5. http://dx.doi.org/10.1109/pesmg.2013.6672175
- Bokhari, A., Alkan, A., Dogan, R., Diaz-Aguilo, M., de Leon, F., Czarkowski, D., Zabar, Z., Birenbaum, L., Noel, A. and Uosef, R.E. (2014) Experimental Determination of the ZIP Coefficients for Modern Residential, Commercial, and Industrial Loads. IEEE Transactions on Power Delivery, 29, 1372-1381. http://dx.doi.org/10.1109/TPWRD.2013.2285096
- Anton, D., Su, K.N. and Kwan, K.Y. (2015) Future Drives of Home Appliances: Elimination of the Electrolytic DC-Link Capacitor in Electrical Drives for Home Appliances. IEEE Industrial Electronics Magazine, 9, 10-18.
- Arco, S.D., Piegari, L. and Tricoli, P. (2014) Harmonic Compensation with Active Front-End Converters Based Only on Grid Voltage Measurements. 3rd Renewable Power Generation Conference (RPG 2014), Naples, 24-25 September 2014, 1-6.
- Fujita, G., Dinh, N.D., Funabashi, T. and Tuyen, N.D. (2015) Adaptive Notch Filter Solution under Unbalanced and/or Distorted Point of Common Coupling Voltage for Three-Phase Four-Wire Shunt Active Power Filter with Sinusoidal Utility Current Strategy. IET Generation, Transmission & Distribution, 9, 1580-1596. http://dx.doi.org/10.1049/iet-gtd.2014.1017