Ride through Strategy for a Three-Level Dual Z-Source Inverter Using TRIAC
- 1 K. Ramakrishnan College of Technology, Trichy, Tamilnadu, India
- 2 K.S.R Institute for Engineering and Technology, Namakkal, Tamilnadu, India
Abstract
A new ride through strategy is introduced in a three - level dual Z-source inverter, for isolation under semiconductor switching failure condition. Here the output will have no significant decrease in the amplitude and quality. Instead of diodes, the triacs are added to the inverter source ends, as it can perform a bidirectional power transfer also it can operate well in both low and high voltage operating conditions. The faulted part can be isolated by simply altering the firing pulses for turning on/off the triacs using the carrier based SPWM technique and resulting in a boosting output with zero common mode voltage. Consequently, it forms a common floating point or null point with a zero common mode voltage. It is experimentally verified by using MATLAB, and digital oscilloscope.
- Peng, F.Z. (2003) Z-Source Inverter. IEEE Transactions on Industry Applications, 39, 504-510. http://dx.doi.org/10.1109/TIA.2003.808920
- Ribeiro, R.L.A., Jacobina, C.B., da Silva, E.R.C. and Lima, A.M.N. (2001) A Fault Tolerant Induction Motor Drive System by Using a Compensation Strategy on the PWM-VSI Topology. 2001 IEEE 32nd Annual Power Electronics Specialists Conference, Vancouver, 17-21 June 2001, 1191-1196. http://dx.doi.org/10.1109/PESC.2001.954281
- Beltrao de Rossiter Correa, M., BrandaoJacobina, C., Cabral da Silva, E.R. and Nogueira Lima, A.M. (2001) An Induction Motor Drive System with Improved Fault Tolerance. IEEE Transactions on Industry Applications, 37, 873-879. http://dx.doi.org/10.1109/28.924770
- Li, S. and Xu, L. (2006) Strategies of Fault Tolerant Operation for Three-Level PWM Inverters. IEEE Transactions on Power Electronics, 21, 933-940. http://dx.doi.org/10.1109/TPEL.2006.876867
- Richardeau, F., Baudesson, P. and Meynard, T.A. (2002) Failures-Tolerance and Remedial Strategies of a PWM Multicell Inverter. IEEE Transactions on Power Electronics, 17, 905-912. http://dx.doi.org/10.1109/TPEL.2002.805588
- Chen, A., Hu, L., Chen, L.F., Deng, Y. and He, X.N. (2005) A Multilevel Converter Topology with Fault-Tolerant Ability. IEEE Transactions on Power Electronics, 20, 405-415. http://dx.doi.org/10.1109/TPEL.2004.842983
- Chokhawala, R.S., Catt, J. and Kiraly, L. (1995) A Discussion on IGBT Short Circuit Behavior and Fault Protection Schemes. IEEE Transactions on Industry Applications, 31, 256- 263. http://dx.doi.org/10.1109/28.370271
- Peuget, R., Courtine, S. and Rognon, J.-P. (1998) Fault Detection and Isolation on a PWM Inverter by Knowledge-Based Model. IEEE Transactions on Industry Applications, 34, 1318-1326. http://dx.doi.org/10.1109/28.739017
- de Araujo Ribeiro, R.L., Jacobina, C.B., da Silva E.R.C. and Lima, A.M.N. (2003) Fault Detection of Open-Switch Damage in Voltage-Fed PWM Motor Drive Systems. IEEE Transactions on Power Electronics, 18, 587-593. http://dx.doi.org/10.1109/TPEL.2003.809351
- da Silva, E.R., Lima, W.S., de Oliveira, A.S., Jacobina, C.B. and Razik, H. (2006) Detection and Compensation of Switch Faults in a Three Level Inverter. IEEE Annual Power Electronics Specialists Conference, July 2006, 1-7. http://dx.doi.org/10.1109/PESC.2006.1711955
- Khomfoi, S. and Tolbert, L.M. (20070 Fault Diagnosis and Reconfiguration for Multilevel Inverter Drive Using AI-Based Techniques. IEEE Transactions on Industrial Electronics, 54, 2954-2968. http://dx.doi.org/10.1109/TIE.2007.906994