Realizations of Voltage Transfer Functions Using DVCCs
- 1 School of Electrical Sciences, IIT Goa, Ponda, India
Abstract
Maheshwari has proposed three differential-voltage current-conveyor configurations for realizing first order all-pass filters only. This paper has exploited these configurations for realizing more complex transfer function T ( s ) which yield poles and zeros of 1 - T ( s ) in one of the four admissible patterns. Bilinear and biquadratic functions are dealt in detail. It is shown that only bilinear functions can be realized with all the four passive elements grounded. First order all-pass function is a special case which needs only three elements (2 R , 1 C ) or (1 R , 2 C ). A biquadratic function requires (2 R , 2 C ) elements and has all the capacitor grounded. Design of second order all-pass function is given.
- Ibrahim, M.A., Minaei, S. and Kuntman, H. (2005) A 22.5 MHz Biquad Using Differential Voltage Current Conveyor and Grounded Passive Elements. International Journal of Electronics and Communications, 59, 311-318.
- Maheshwari, S. (2007) High Input Impedance VM-APSs with Grounded Passive Elements. IET Circuits, Devices and Systems, 1, 72-78. https://doi.org/10.1049/iet-cds:20060196
- Rathore, T.S. and Khot, U.P. (2005) Single FTFN Realization of Current Transfer Functions. IETE Journal of Research, 51, 193-199. https://doi.org/10.1080/03772063.2005.11416395