Binding kinetics enhancement of a microfluidic biosensor into a micro-channel through the application of a supplementary mechanism has received tremendous attention because of the obtained significant enhancement factor. However, biosensor’s performance enhancement using only simple channel engineering is still rarely realized. Herein, we present a novel design of a complex reactive protein (CRP) biosensor into a U-shaped channel with a sensitive membrane located in the middle of the bent zone. Various critical factors affecting the equilibrium binding time are numerically investigated. The turn geometry is then optimized when the arc length along the inner and outer radii is almost the same, which leads to locally minimizing the channel height overhead the reaction surface and improves the analyte transport towards the sensing area. The numerical studies reveal that applying a local narrowing above the reaction surface can notably enhance the trapping and the surface formation of complex antibody-antigen, thus upgrading the biosensor performance. This work puts a significant advance towards microfluidic channel engineering and the exploration of micro-flow injection experimental studies.
KeywordsFinite Elements MethodBinding ReactionCRP BiosensorMicrofluidic SystemMicrochannel TurnNumerical Simulation
Younes, T.M., AlKhedher, M.A., Shgier, K.A. and Al Taweel, F. (2019) U-Shape Acoustic Liquid Densitometer. Instrumentation Mesure Metrologie, 18, 123-128. https://doi.org/10.18280/i2m.180205
Rechberger, A., Amsüss, R., Rossegger, S., Breidler, R. and Steiner, G. (2019) High Precision Vibration-Type Densitometers Based on Pulsed Excitation Measurements. Sensors, 19, Article No. 1627. https://doi.org/10.3390/s19071627
Ong, K.S., Tong, W.L. and Choong, J.K. (2016) Performance of U-Tube Solar Water Heater with Vertical and Inclined Panels. International Journal of Low-Carbon Technologies, 11, 248-253. https://doi.org/10.1093/ijlct/ctt063
Alsabbah, S. and Mughrabi, T. (2008) Neural Network-Based Waveguide Acoustic Gas Detector. Proceeding 5th International Symposium on Mechatronics and Its Applications (ISMA 2008), Amman, 27-29 May 2008, 1-4. https://doi.org/10.1109/ISMA.2008.4648867
Younes, T.M., Alia, M.A.K. and Al-Sabbah, S. (2010) Acoustic Temperature Transducer. Sensors & Transducers, 119, 46-57.
Outcalt, S.L. and McLinden, M.O. (2007) Automated Densimeter for the Rapid Characterization of Industrial Fluids. Industrial & Engineering Chemistry Research, 46, 8264-8269. https://doi.org/10.1021/ie070791e
Fang, Y.-L., Wang, C.-T. and Chiang, C.-C. (2016) A Small U-Shaped Bending-Induced Interference Optical Fiber Sensor for the Measurement of Glucose Solutions. Sensors, 16, Article No. 1460. https://doi.org/10.3390/s16091460
Raoufi, N., Surre, F., Rajarajan, M., Sun, T. and Grattan, K.T.V. (2014) Fiber Optic pH Sensor Using Optimized Layer-by-Layer Coating Approach. IEEE Sensors Journal, 14, 47-54. https://doi.org/10.1109/JSEN.2013.2280283
Chiang, C.C. and Chao, J.C. (2013) Whispering Gallery Mode Based Optical Fiber Sensor for Measuring Concentration of Salt Solution. Journal of Nanomaterials, 2013, Article ID: 372625. https://doi.org/10.1155/2013/372625
Llorente, V.B., Erro, E.M., Baruzzi, A.M. and Iglesias, R.A. (2015) Optochemical Fiber Sensor for Toluidine Blue Detection in High Turbidity Media. Sensors and Actuators B: Chemical, 216, 316-320. https://doi.org/10.1016/j.snb.2015.03.085
Qiu, B., Gong, L., Li, Z. and Han, J. (2019) Electrokinetic Flow in the U-Shaped Micro-Nanochannels. Theoretical and Applied Mechanics Letters, 9, 36-42. https://doi.org/10.1016/j.taml.2019.01.006
Wen, H.Y., Huang, C.W., Le Li, Y., Chen, J.L., Yeh, Y.T. and Chiang, C.C. (2020) A Lamping U-Shaped Fiber Biosensor Detector for MicroRNA. Sensors, 20, Article No. 1509. https://doi.org/10.3390/s20051509
Bharadwaj, R., Sai, V.V.R., Thakare, K., Dhawangale, A., Kundu, T., Titus, S., Verma, P.K. and Mukherji, S. (2011) Evanescent Wave Absorbance Based Fiber Optic Biosensor for Label-Free Detection of E. coli at 280 nm Wavelength. Biosensors and Bioelectronics, 26, 3367-3370. https://doi.org/10.1016/j.bios.2010.12.014
Littlejohn, D., Lucas, D. and Han, L. (1999) Bent Silica Fiber Evanescent Absorption Sensors for Near-Infrared Spectroscopy. Applied Spectroscopy, 53, 845-849. https://doi.org/10.1366/0003702991947423
Radadia, A.D., Salehi-Khojin, A., Masel, R.I. and Shannon, M.A. (2010) The Effect of Microcolumn Geometry on the Performance of Micro-Gas Chromatography Columns for Chip Scale Gas Analyzers. Sensors and Actuators B: Chemical, 150, 456-464. https://doi.org/10.1016/j.snb.2010.07.002
Molho, J.I., Herr, A.E., Mosier, B.P., Santiago, J.G., Kenny, T.W., Brennen, R.A., Gordon, G.B. and Mohammadi, B. (2001) Optimization of Turn Geometries for Microchip Electrophoresis. Analytical Chemistry, 73, 1350-1360. https://doi.org/10.1021/ac001127+
Griffiths, S.K. and Nilson, R.H. (2000) Band Spreading in Two-Dimensional Microchannel Turns for Electrokinetic Species Transport. Analytical Chemistry, 72, 5473-5482. https://doi.org/10.1021/ac000595g
Paegel, B.M., Hutt, L.D., Simpson, P.C. and Mathies, R.A. (2000) Turn Geometry for Minimizing Band Broadening in Microfabricated Capillary Electrophoresis Channels. Analytical Chemistry, 72, 3030-3037. https://doi.org/10.1021/ac000054r
Bahri, M., Dermoul, I., Getaye, M., Ben Ali, M. and Abdelhamid, E. (2019) 2D Simulation of a Microfluidic Biosensor for CRP Detection into a Rotating Micro-Channel. SN Applied Sciences, 1, Article No. 1199. https://doi.org/10.1007/s42452-019-1231-8
Selmi, M., Echouchene, F., Gazzah, M.H. and Belmabrouk, H. (2015) Flow Confinement Enhancement of Heterogeneous Immunoassays in Microfluidics. IEEE Sensors Journal, 15, 7321-7328. https://doi.org/10.1109/JSEN.2015.2475610
Sigurdson, M., Wang, D. and Meinhart, C.D. (2005) Electrothermal Stirring for Heterogeneous Immunoassays. Lab on a Chip, 5, 1366-1373. https://doi.org/10.1039/b508224b
Munir, A., Wang, J., Li, Z. and Zhou, H.S. (2010) Numerical Analysis of a Magnetic Nanoparticle-Enhanced Microfluidic Surface-Based Bioassay. Microfluidics and Nanofluidics, 8, 641-652. https://doi.org/10.1007/s10404-009-0497-3
Selmi, M., Echouchene, F. and Belmabrouk, H. (2016) Analysis of Microfluidic Biosensor Efficiency Using a Cylindrical Obstacle. Sensor Letters, 14, 26-31. https://doi.org/10.1166/sl.2016.3527
Selmi, M., Khemiri, R., Echouchene, F. and Belmabrouk, H. (2016) Electrothermal Effect on the Immunoassay in a Microchannel of a Biosensor with Asymmetrical Interdigitated Electrodes. Applied Thermal Engineering, 105, 77-84. https://doi.org/10.1016/j.applthermaleng.2016.05.132
Azad, N., Rojanasakul, Y. and Vallyathan, V. (2008) Inflammation and Lung Cancer: Roles of Reactive Oxygen/Nitrogen Species. Journal of Toxicology and Environmental Health, Part B, 11, 1-15. https://doi.org/10.1080/10937400701436460
Pepys, M.B. and Hirschfield, G.M. (2003) C-Reactive Protein: A Critical Update. Journal of Clinical Investigation, 111, 1805-1812. https://doi.org/10.1172/JCI200318921
Ji, M., Du, L., Ma, Z., Xie, J., Huang, Y., Wei, X., Jiang, X., Xu, J., Yin, R., Wang, Y., Dai, J., Jin, G., Xu, L., Zhu, C., Hu, Z., Ma, H., Zhu, M. and Shen, H. (2022) Circulating C-Reactive Protein Increases Lung Cancer Risk: Results from a Prospective Cohort of UK Biobank. International Journal of Cancer, 150, 47-55. https://doi.org/10.1002/ijc.33780
Yi, M., Zhang, H., Qi, S. and Li, Q. (2016) Determination of C-Reactive Protein Concentration in Serum Based on Chemiluminescence Analysis. 2016 8th International Conference on Measuring Technology and Mechatronics Automation (ICMTMA 2016), Macau (China), 11-12 March 2016, 214-217. https://doi.org/10.1109/ICMTMA.2016.61
Kuzmin, D. and Hamalainen, J. (2016) Finite Element Methods for Computational Fluid Dynamics?: A Practical Guide. Society for Industrial and Applied Mathematics, Philadelphia.
Yang, C.K., Chang, J.S., Chao, S.D. and Wu, K.C. (2008) Effects of Diffusion Boundary Layer on Reaction Kinetics of Immunoassay in a Biosensor. Journal of Applied Physics, 103, Article ID: 084702. https://doi.org/10.1063/1.2909980
Thompson, J.A. and Bau, H.H. (2010) Microfluidic, Bead-Based Assay: Theory and Experiments. Journal of Chromatography B, 878, 228-236. https://doi.org/10.1016/j.jchromb.2009.08.050
Huang, K.R. and Chang, J.S. (2013) Three Dimensional Simulation on Binding Efficiency of Immunoassay for a Biosensor with Applying Electrothermal Effect. Heat and Mass Transfer, 49, 1647-1658. https://doi.org/10.1007/s00231-013-1214-z
Sadana, A. and Vo-Dinh, T. (1997) Antibody-Antigen Binding Kinetics a Model for Multivalency Antibodies for Large Antigen Systems. Biotechnology and Applied Biochemistry, 67, 1-22. https://doi.org/10.1007/BF02787837
Zimmermann, M., Delamarche, E., Wolf, M. and Hunziker, P. (2005) Modeling and Optimization of High-Sensitivity, Low-Volume Microfluidic-Based Surface Immunoassays. Biomedical Microdevices, 7, 99-110. https://doi.org/10.1007/s10544-005-1587-y
Stone, H.A., Stroock, A.D. and Ajdari, A. (2004) Engineering Flows in Small Devices: Microfluidics toward a Lab-on-a-Chip. Annual Review of Fluid Mechanics, 36, 381-411. https://doi.org/10.1146/annurev.fluid.36.050802.122124
Aoun, N., Echouchene, F., Diallo, A.K., Launay, J. and Belmabrouk, H. (2016) Finite-Element Simulations of the pH-ElecFET Microsensors. IEEE Sensors Journal, 16, 6519-6526. https://doi.org/10.1109/JSEN.2016.2585506
Chaiken, I., Rosé, S. and Karlsson, R. (1992) Analysis of Macromolecular Interactions Using Immobilized Ligands. Analytical Biochemistry, 201, 197-210. https://doi.org/10.1016/0003-2697(92)90329-6
Levich, V. (1962) Physicochemical Hydrodynamics. Englewood Cliffs, Prentice-Hall. http://www.worldcat.org/title/physicochemical-hydrodynamics/oclc/1378432
Hofmann, O., Voirin, G., Niedermann, P. and Manz, A. (2002) Three-Dimensional Microfluidic Confinement for Efficient Sample Delivery to Biosensor Surfaces. Application to Immunoassays on Planar Optical Waveguides. Analytical Chemistry, 74, 5243-5250. https://doi.org/10.1021/ac025777k