Research ArticleOpen AccessGoogle Scholar indexed
Influence of Heat Exchange Coefficients on Both Optimized Thermal Contact (OTCR) and Critical (CTCR) Resistances at the Contact Interface of a Flat Concrete Slab and a Rice Straw Board
Polytechnic School of Thiès, Thiès, Senegal
Polytechnic School of Thiès, Thiès, Senegal
Polytechnic School of Thiès, Thiès, Senegal
Polytechnic School of Thiès, Thiès, Senegal
Laboratory of Semiconductors and Solar Energy, Physics Department, Faculty of Science and Technology, University Cheikh Anta Diop, Dakar, Senegal
Laboratory of Semiconductors and Solar Energy, Physics Department, Faculty of Science and Technology, University Cheikh Anta Diop, Dakar, Senegal
Laboratory of Semiconductors and Solar Energy, Physics Department, Faculty of Science and Technology, University Cheikh Anta Diop, Dakar, Senegal
University Institute of Technology, University Iba Der THIAM of Thiès, Thiès, Sénégal
Groupe International de Recherche en Energie Renouvelable, Dakar, Senegal
- 1 Polytechnic School of Thiès, Thiès, Senegal
- 2 Polytechnic School of Thiès, Thiès, Senegal
- 3 Polytechnic School of Thiès, Thiès, Senegal
- 4 Polytechnic School of Thiès, Thiès, Senegal
- 5 Laboratory of Semiconductors and Solar Energy, Physics Department, Faculty of Science and Technology, University Cheikh Anta Diop, Dakar, Senegal
- 6 Laboratory of Semiconductors and Solar Energy, Physics Department, Faculty of Science and Technology, University Cheikh Anta Diop, Dakar, Senegal
- 7 Laboratory of Semiconductors and Solar Energy, Physics Department, Faculty of Science and Technology, University Cheikh Anta Diop, Dakar, Senegal
- 8 University Institute of Technology, University Iba Der THIAM of Thiès, Thiès, Sénégal
- 9 Groupe International de Recherche en Energie Renouvelable, Dakar, Senegal
Energy and Power Engineering·Volume 13 (2021)·Pages 392–402·Published 7 December 2021·DOI10.4236/epe.2021.1312027
Copy link · social · email
Abstract
The study is carried out in imperfect contact with a concrete slab wall attached to a panel based on rice straw compressed in a dynamic frequency regime. We will propose the characterization of thermal insulation for thermal resistance of contact ( x = 0.05 m). The impact of heat exchange coefficients on the front face ( x = 0 m) and the rear face ( x = 0.1 m) on these resistors is shown.
KeywordsConcrete SlabRice Straw BoardThermal Resistance of ContactFrequency Dynamic
- Rojey, A. (2008) Energie et climat: Réussir la transition énergétique. Edition TECHNIP.
- Kremnev, V., Basok, B., Timoshchenko, A. and Tymchyshyn, S. (2018) Energy Saving in Construction by Wide Application of High-Quality Insulation Based on Basalt Fibers. Journal of Modern Physics, 9, 1724-1734. http://www.scirp.org/journal/jmp https://doi.org/10.4236/jmp.2018.99108
- Silva de Andrade, F., Mobasher, B., Soranakom, C. and Toledo Filho, R.D. (2011) Effect of Fiber Shape and Morphology on Interfacial Bond and Cracking Behaviors of Sisal Fiber Cement Based Composites. Cement & Concrete Composites, 33, 814-823. https://doi.org/10.1016/j.cemconcomp.2011.05.003
- Hejazi, M.S., Sheikhzadeh, M., Abtahi, M.S. and Zadhoush, A. (2012) A Simple Review of Soil Reinforcement by Using Natural and Synthetic Fibers. Construction and Building Materials, 30, 100-116. https://doi.org/10.1016/j.conbuildmat.2011.11.045
- Janno, Y., Degiovanni, T.A. and Payet, G. (2009) Thermal Conductivity Measurement of Insulating Materials with a Three Layers Device. International Journal of Heat and Mass Transfer, 52, 1105-1111. https://doi.org/10.1016/j.ijheatmasstransfer.2008.09.017
- Gaye, S., Sissoko, G., Azilinon, D. and Adj, M. (2001) Qualification of Thermal Comfort in Humid Tropical Climates. ASME Journal, 70, 37-50.
- Voumbo, W., Gaye, S., Adj, M. and Sissoko, G. (2010) Characterization of the Thermo Physical Properties of Kapok. Research Journal of Applied Sciences, Engineering and Technology, 2, 143-148.
- Thiam, S.K.B., Ba, A., Ndiaye, M.B., Diagne, I., Traore, Y., Faye, S., Thiam, C., Traore, P.T., Fame, A. and Sissoko, G. (2020) One-Dimensional Study of Thermal Behavior of Typha Panel: Spectroscopy Characterization of Heat Exchange Coefficient on Front Face. Journal of Sustainable Bioenergy Systems, 10, 52-61. https://www.scirp.org/journal/jsbs
- Brahim, M.S.O., Diagne, I., Ndiaye, M.B., Traore, Y., Faye, S., Thiam, C., Traore, P.T., Fame, A., Thiam, S.K.B. and Sissoko, G. (2020) Study at Two Dimensions of Thermal Transfer through a Fibers Panel Subjected to Climatic Constraints in Dynamic Frequency Regulations Established. Energy and Power Engineering, 12, 135-142. https://www.scirp.org/journal/paperinformation.aspx?paperid=100079 https://doi.org/10.4236/epe.2020.125010
- Traore, Y., Diagne, I., Sarr, C., Brahim, M.S.O., Diallo, A.K., Ly Diallo, H. and Sissoko, G. (2016) Influence of Thermal Exchange Coefficient on the Heat Retention Rate of a Concrete Wall Contiguous to a Thermal Insulation Tow-Plaster. ARPN Journal of Engineering and Applied Sciences, 11, 2835-2840.