Numerical Analysis on Temperature Distribution in a Single Cell of PEFC Operated at Higher Temperature by1D Heat Transfer Model and 3D Multi-Physics Simulation Model — Oak Academic Publishing
Research ArticleOpen AccessGoogle Scholar indexed
Numerical Analysis on Temperature Distribution in a Single Cell of PEFC Operated at Higher Temperature by1D Heat Transfer Model and 3D Multi-Physics Simulation Model
Division of Mechanical Engineering, Graduate School of Engineering, Mie University, Tsu, Japan
,
Division of Mechanical Engineering, Graduate School of Engineering, Mie University, Tsu, Japan
,
Division of Mechanical Engineering, Graduate School of Engineering, Mie University, Tsu, Japan
,
Division of Mechanical Engineering, Graduate School of Engineering, Mie University, Tsu, Japan
1 Division of Mechanical Engineering, Graduate School of Engineering, Mie University, Tsu, Japan
2 Division of Mechanical Engineering, Graduate School of Engineering, Mie University, Tsu, Japan
3 Division of Mechanical Engineering, Graduate School of Engineering, Mie University, Tsu, Japan
4 Division of Mechanical Engineering, Graduate School of Engineering, Mie University, Tsu, Japan
This study is to understand the impact of operating conditions, especially initial operation temperature ( T ini ) which is set in a high temperature range, on the temperature profile of the interface between the polymer electrolyte membrane (PEM) and the catalyst layer at the cathode (i.e., the reaction surface) in a single cell of polymer electrolyte fuel cell (PEFC). A 1D multi-plate heat transfer model based on the temperature data of the separator measured using the thermograph in a power generation experiment was developed to evaluate the reaction surface temperature ( T react ). In addition, to validate the proposed heat transfer model, T react obtained from the model was compared with that from the 3D numerical simulation using CFD software COMSOL Multiphysics which solves the continuity equation, Brinkman equation, Maxwell-Stefan equation, Butler-Volmer equation as well as heat transfer equation. As a result, the temperature gap between the results obtained by 1D heat transfer model and those obtained by 3D numerical simulation is below approximately 0.5 K. The simulation results show the change in the molar concentration of O 2 and H 2 O from the inlet to the outlet is more even with the increase in T ini due to the lower performance of O 2 reduction reaction. The change in the current density from the inlet to the outlet is more even with the increase in T ini and the value of current density is smaller with the increase in T ini due to the increase in ohmic over-potential and concentration over-potential. It is revealed that the change in T react from the inlet to the outlet is more even with the increase in T ini irrespective of heat transfer model. This is because the generated heat from the power generation is lower with the increase in T ini due to the lower performance of O 2 reduction reaction.
KeywordsPEFCHeat Transfer ModelTemperature DistributionNumerical SimulationHigh Temperature Operation
NEDO (New Energy and Industry Technology Development Organization) (2022). http://www.nedo.go.jp/content/100871976.pdf
Zhang, J., Wang, H., Li, W., Zhang, J., Lu, D., Yan, W., Xiang, Y. and Lu, S. (2021) Effect of Catalyst Layer Microstructures on Performance and Stability for High Temperature Polymer Electrolyte Membrane Fuel Cells. Journal of Power Sources, 505, Article ID: 230059. https://doi.org/10.1016/j.jpowsour.2021.230059
Zhang, G. and Kandlikar, S.G.A. (2012) Critical Review of Cooling Technique in Proton Exchange Membrane Fuel Cell Stacks. International Journal of Hydrogen Energy, 37, 2412-2429. https://doi.org/10.1016/j.ijhydene.2011.11.010
Agbossou, K., Kolhe, M., Hamelin, J. and Bose, T.K. (2004) Performance of a Stand-Alone Renewable Energy System Based on Energy Storage as Hydrogen. IEEE Transactions on Energy Conversion, 19, 633-640. https://doi.org/10.1109/TEC.2004.827719
Li, Q., He, R., Jensen, J.O. and Bjerrum, N.J. (2003) Approaches and Recent Development Polymer Electrolyte Membrane for Fuel Cells Operating above 100 °C. Chemical of Materials, 15, 4896-4915. https://doi.org/10.1021/cm0310519
Lee, C.Y., Weng, F.B., Kuo, Y.W., Cheng, C.H., Cheng, C.K. and Lin, J.T. (2016) In-Situ Measurement of High-Temperature Resistant Integrated Microsensor Embedded in High Temperature Proton Exchange Membrane Fuel Cell Stack. Sensors, 16, Article No. 1731. https://doi.org/10.3390/s16101731
Lee, C.Y., Weng, F.B., Kuo, Y.W., Cheng, Y.T., Cheng, C.K., Tsai, C.H. and Lee, T.J. (2016) Persistent Effect Test for High Temperature Resistant Integrated Microsensor Embedded in High Temperature Proton Exchange Membrane Fuel Cell Stack. Sensors and Actuators A: Physical, 250, 202-209. https://doi.org/10.1016/j.sna.2016.09.026
Wang, M., Guo, H. and Ma, C. (2006) Temperature Distribution on the MEA Surface of a PEMFC with Serpentine Channel Flow Bed. Journal of Power Sources, 157, 181-187. https://doi.org/10.1016/j.jpowsour.2005.08.012
Tsuji, K. (2008) Domestic Fuel Cell Co-Generation System Entering Real Commercial Stage. Hydrogen Energy System, 33, 93-96.
Ryu, S.K., Vinothkannan, M., Kim, A.R. and Yoo, D.J. (2022) Effect of Type and Stoichiometry of Fuels on Performance of Polybenzimidazole-Based Proton Exchange Membrane Fuel Cells Operating at the Temperature Range of 120-160 °C. Energy, 238, Article ID: 121791. https://doi.org/10.1016/j.energy.2021.121791
Budak, Y. and Devrim, Y. (2022) Micro-Cogeneration Application of a High-Temperature PEM Fuel Cell Stack Operated with Polybenzimidazole Based Membranes. International Journal of Hydrogen Energy, 45, 35198-35207. https://doi.org/10.1016/j.ijhydene.2019.11.173
Kim, D.K., Kim, H., Park, H., Oh, S., Ahn, S.H., Kim, H.J. and Kim, S.K. (2019) Performance Enhancement of High-Temperature Polymer Electrolyte Membrane Fuel Cells Using Pt Pulse Electrodeposition. Journal of Power Sources, 438, Article ID: 227022. https://doi.org/10.1016/j.jpowsour.2019.227022
Kanchan, B.K., Randive, P. and Pati, S. (2021) Implications of Non-Uniform Porosity Distribution in Gas Diffusion Layer on the Performance of a High Temperature PEM Fuel Cell. International Journal of Hydrogen Energy, 46, 18571-18588. https://doi.org/10.1016/j.ijhydene.2021.03.010
Xia, L., Ni, M., He, Q., Xu, Q. and Cheng, C. (2021) Optimization of Gas Diffusion Layer in High Temperature PEMFC with the Focuses on Thickness and Porosity. Applied Energy, 300, Article ID: 117357. https://doi.org/10.1016/j.apenergy.2021.117357
Agarwal, H., Thosar, A.U., Bhat, S.D. and Lele, A.K. (2022) Interdigitated Flow Field Impact on Mass Transport and Electrochemical Reaction in High-Temperature Polymer Electrolyte Fuel Cell. Journal of Power Sources, 532, Article ID: 231319. https://doi.org/10.1016/j.jpowsour.2022.231319
Xia, L., Xu, Q., He, Q., Ni, M. and Seng, M. (2021) Numerical Study of High Temperature Proton Exchange Membrane Fuel Cell (HT-PEFC) with a Focus on Rib Design. International Journal of Hydrogen Energy, 46, 21098-21111. https://doi.org/10.1016/j.ijhydene.2021.03.192
Huang, T., Wang, W., Yuan, Y., Huang, J., Chen, X., Zhang, J., Kong, X., Zhang, Y. and Wan, Z. (2021) Optimization of High-Temperature Proton Exchange Membrane Fuel Cell Flow Channel Based on Genetic Algorithm. Energy Reports, 7, 1374-1384. https://doi.org/10.1016/j.egyr.2021.02.062
Zhang, J., Zhang, C., Hao, D., Ni, M., Hung, S., Liu, D. and Zheng, Y. (2021) 3D Non-Isothermal Dynamic Simulation of High Temperature Proton Exchange Membrane Fuel Cell in Start-Up Process. International Journal of Hydrogen Energy, 46, 2577-2593. https://doi.org/10.1016/j.ijhydene.2020.10.116
Nishimura, A., Kono, N., Toyoda, K., Mishima, D. and Kolhe, M.L. (2022) Impact of Separator Thickness on Temperature Distribution in Single Cell of Polymer Electrolyte Fuel Cell Operated at Higher Temperature of 90°C and 100°C. Energies, 15, Article No. 4203. https://doi.org/10.3390/en15124203
Nishimura, A., Toyoda, K., Mishima, D., Ito, S. and Hu, E. (2022) Numerical Analysis on Impact of Thickness of PEM and GDL with and without MPL on Coupling Phenomena in PEFC Operated at Higher Temperature Such as 363 K and 373 K. Energies, 15, Article No. 5936. https://doi.org/10.3390/en15165936
Nishimura, A., Kono, N., Toyoda, K., Kojima, Y. and Kolhe, M.L. (2021) Impact Analysis of MPL on a PEFC Cell’s Temperature Distribution with Thin PEM and GDL for Operating at Higher Temperature than Usual. Journal of Energy and Power Engineering, 15, 39-51. https://doi.org/10.17265/1934-8975/2021.02.001
Nishimura, A., Yamamoto, K., Okado, Y., Kojima, Y., Hirota, M. and Kolhe, M.L. (2020) Impact of Analysis of MPL and PEM Thickness on Temperature Distribution with PEFC Operating at Relatively Higher Temperature. Energy, 205, Article ID: 117875. https://doi.org/10.1016/j.energy.2020.117875
Nishimura, A., Sato, Y., Kamiya, S., Okado, T., Yamamoto, K., Hirota, M. and Hu, E. (2019) Impact of Thickness of Polymer Electrolyte Membrane and Gas Diffusion Layer on Temperature Distribution in Polymer Electrolyte Fuel Cell Operated at Temperature around 90 °C. Journal of Energy and Power Engineering, 13, 97-115. https://doi.org/10.17265/1934-8975/2019.03.002
Nishimura, A., Sato, Y., Yoshimura, M., Kamiya, S. and Hirota, M. (2018) Impact of Thickness of Polymer Electrolyte Membrane on Temperature Distribution in Single Cell of Polymer Electrolyte Fuel Cell Operated at High Temperature. Journal of Energy and Power Engineering, 12, 80-92. https://doi.org/10.17265/1934-8975/2018.02.004
Nishimura, A., Iio, K., Baba, M., Yamauchi, T., Hirota, M. and Hu, E. (2014) Modeling of Heat Transfer in Single Cell of Polymer Electrolyte Fuel Cell by Means of Temperature Data Measured by Thermograph. Journal of Chemical Engineering of Japan, 47, 521-529. https://doi.org/10.1252/jcej.13we275
Nishimura, A., Shibuya, K., Morimoto, A., Tanaka, S., Hirota, M., Nakamura, Y., Kojima, M., Narita, M. and Hu, E. (2012) Dominant Factor and Mechanism of Coupling Phenomena in Single Cell of Polymer Electrolyte Fuel Cell. Applied Energy, 90, 73-79. https://doi.org/10.1016/j.apenergy.2011.01.003
Khandelwah, M. and Mench, M.M. (2006) Direct Measurement of Through-Plane Thermal Conductivity and Contact Resistance in Fuel Cell Materials. Journal of Power Sources, 161, 1106-1115. https://doi.org/10.1016/j.jpowsour.2006.06.092
The Japan Society of Mechanical Engineers (1993) JSME Heat Transfer Handbook. Maruzen, Tokyo, 387.
Penga, Z., Tolj, I. and Barbir, F. (2016) Computational Fluid Dynamics Study of PEM Fuel Cell Performance. International Journal of Hydrogen Energy, 41, 17585-17594. https://doi.org/10.1016/j.ijhydene.2016.07.092
Kawase, M., Inagaki, T., Kawashima, S. and Miura, K. (2009) Effective Thermal Conductivity of Gas Diffusion Layer in Through-Plane Direction. ECS Transactions, 25, 1529-1537. https://doi.org/10.1149/1.3210709
Oshima, A., Nishimura, A., Morimoto, A., Tanaka, S., Hirota, M. and Narita, M. (2010) Theoretical Investigation on Influence of Inflow Gas Condition and Gas Channel Structure of Separator on Mass and Temperature Distribution in Single Cell of Polymer Electrolyte Fuel Cell. Preprints of Mechanical Engineering Congress, 203-204.
Jung, C.Y., Shim, H.S., Koo, S.M., Lee, S.F. and Yi, S.C. (2012) Investigations of the Temperature Distribution in Proton Exchange Membrane Fuel Cell. Applied Energy, 93, 733-741. https://doi.org/10.1016/j.apenergy.2011.08.035
Das, S.K. and Gibson, H.A. (2021) These Dimensional Multi-Physics Modeling and Simulation for Assessment of Mass Transport Impact on the Performance of a High Temperature Polymer Electrolyte Membrane Fuel Cell. Journal of Power Sources, 499, 161-188. https://doi.org/10.1016/j.jpowsour.2021.229844
Nishimura, A., Toyoda, K., Kojima, Y. and Kolhe, M.L. (2021) Numerical Simulation on Impacts of Thickness of Nafion Series Membranes and Relative Humidity on PEMFC Operated at 363 K and 373 K. Energies, 14, Article No. 8256. https://doi.org/10.3390/en14248256
Chen, H., Guo, H., Ye, F. and Ma, C.F.A. (2021) Numerical Study on Oriented-Type Flow Channels with Porous-Blocked Baffles of Proton Exchange Membrane Fuel Cells. International Journal of Hydrogen Energy, 46, 29443-29458. https://doi.org/10.1016/j.ijhydene.2020.12.178
Nishimura, A., Okado, T., Kojima, Y. and Hu, E. (2021) Impact of MPL on Temperature Distribution in Single Polymer Electrolyte Fuel Cell with Various Thickness of Polymer Electrolyte Membrane. Energies, 13, Article No. 2499. https://doi.org/10.3390/en13102499
Nishimura, A., Kamiya, S., Okado, T., Sato, Y., Hirota, M. and Kolhe, M.L. (2019) Heat and Mass Transfer Analysis in Single Cell of PEFC Using Different PEM and GDL at Higher Temperature. International Journal of Hydrogen Energy, 44, 29631-29640. https://doi.org/10.1016/j.ijhydene.2019.05.192
Copper, N.J., Santamaria, A.D., Becton, M.K. and Park, J.W. (2017) Neutron Radiography Measurement of In-situ PEMFC Liquid Water Saturation in 2D & 3D Morphology Gas Diffusion Layers. International Journal of Hydrogen Energy, 42, 16269-16678. https://doi.org/10.1016/j.ijhydene.2017.05.105
Rostami, L., Nejad, P.M.G. and Vatani, A.A. (2016) Numerical Investigation of Serpentine Flow Channel with Different Bend Sizes in Polymer Electrolyte Membrane Fuel Cells. Energy, 97, 400-410. https://doi.org/10.1016/j.energy.2015.10.132
Senn, S.M. and Poulikakos, D. (2004) Polymer Electrolyte Fuel Cells with Porous Materials as Fluid Distributions and Comparisons with Traditional Channelled Systems. Transactions of ASME, 126, 410-418. https://doi.org/10.1115/1.1738424
Takayama, T. (2018) Numerical Simulation of Transient International States of PEFC Cell and Stack Considering Control of Anode System. Research Report of Mizuho Research Technology, 9, 1-14.
Xing, L., Das, P.K., Song, X., Mamlouk, M. and Scott, K. (2015) Numerical Analysis of the Optimum Membrane/Ionomer Water Content of PEMFCs: The Interface of Nafion Ionomer Content and Cathode Relative Humidity. Applied Energy, 138, 242-257. https://doi.org/10.1016/j.apenergy.2014.10.011
Akimoto, K., Sasabe, T., Yoshida, T., Naito, H., Kawamura, K. and Hirai, S. (2019) Investigation of Effects of High Temperature and Pressure on a Polymer Electrolyte Fuel Cell with Polarization Analysis and X-Ray Imaging of Liquid Water. Journal of Power Sources, 431, 205-209. https://doi.org/10.1016/j.jpowsour.2019.04.115
Jia, T., Shen, S., Zhao, J., Jin, J., Pan, B., Duan, X., Meng, C. and Che, Q. (2020) Ultrathin Membranes Formation via the Layer by Layer Self-Assembly of Carbon Nanotubes-Based Inorganics as High Temperature Proton Exchange Membranes. International Journal of Hydrogen Energy, 45, 14517-14527. https://doi.org/10.1016/j.ijhydene.2020.03.175
Miao, T., Tongsh, C., Wang, J., Cheng, P., Liang, J., Wang, Z., Chen, W., Zhang, C., Xi, F., Du, Q., Wang, B., Bai, F. and Jiao, K. (2022) Current Density and Temperature Distribution Measurement and Homogeneity Analysis for a Large-Area Proton Exchange Membrane Fuel Cell. Energy, 239, Article ID: 121922. https://doi.org/10.1016/j.energy.2021.121922
Springer, T.E., Zawodzinski, T.A. and Gottesfeld, D. (1991) Polymer Electrolyte Fuel Cell Model. Journal of the Electrochemical Society, 138, 2334-2341. https://doi.org/10.1149/1.2085971
Zhou, J., Shukla, S., Putz, A. and Secanell, M. (2018) Analysis of the Role of the Microporous Layer in Improving Polymer Electrolyte Fuel Cell Performance. Electrochimica Acta, 268, 366-382. https://doi.org/10.1016/j.electacta.2018.02.100