The Implications of Fluorescent Lamp Electronic Ballast Dimming —An Experimental Study
- 1
- 2
- 3
- 4
Abstract
In recent years, fluorescent lamp dimming controls are an integral part of daylight artificial light integrated schemes intended for realization of energy savings. However, dimming, like any lighting option, presents its own particular challenges and potential tradeoffs. In view of this, the present manuscript depicts the preliminary work progress carried out to arrive at a comprehensive idea on dimming implications on key factors: electrical characteristics, photometric distributions of lighting systems and influence on quality as well as quantity of visual environment. The objective is to experimentally establish the acceptable range of dimming control voltage that would satisfy both electrical and photometric performance of luminaire. The vital part of the paper is devoted towards presentation of measurement results. For the experimental analysis, three representative samples of different commercial analog 1-10VDC electronic dimmable ballasts and fluorescent fixtures are compared and evaluated over their control voltage dimming range.
- S. G. Colaco, C. P. Kurian, V. I. George, and A. M. Colaco, “Prospective techniques of effective daylight harvesting in commercial buildings by employing window glazing, dynamic shading devices and dimming control-A literature review,” Building Simulation, Vol. 1, No. 4. P. 279–289, 2008.
- C. P. Kurian, R. S. Aithal, J. Bhat, and V. I. George, “Robust control and optimization of energy consumption in daylight-Artificial light integrated schemes,” Lighting Research and Technology, Vol. 40, No. 4, pp. 7–24, 2008.
- M. S. Rea, “Lighting handbook: Reference and application,” Illuminating Engineering Society of North America (IESNA), 9th Edition, New York, 2000.
- C. D. Louie, “Linear fluorescent dimming ballasts: Technology, methods,” Protocols Lighting Controls Association, 2004, http://www.aboutlightingcontrols.org/education/papers/dimming.shtml)
- E. Tetri and V. Gligor, “Dimming according to daylight- effect on lamp life,” Right Light 5, Proceedings of the 5th European Conference on Energy-Efficient Lighting. Nice, France, pp. 421–424, 2002.
- Y. Akashi and J. Neches, “Detectability and acceptability of. illuminance reduction for load shedding,” Journal of Illuminating Engineering Society, Vol. 33, No. 1, pp. 3– 13, 2004.
- M. Etezadi-Amoli and T. Florence, “Power factor and harmonic distortion characteristics of energy efficient lamps,” IEEE Transactions on Power Delivery lamps, Vol. 4, No. 3, pp. 1965–1969, 1989.
- J. Yunfen, D. Robert, C. O'Rourke, E. Wai Mun Chui, “Compatibility testing of fluorescent lamp and ballast systems,” IEEE Transactions on Industry Applications Vol. 35, No. 6, pp. 1271–1276, 1999.
- “Dimming Electronic Ballasts,” National Lighting Product Information Program Specifier Reports, Troy, Lighting Research Center, NY, Rensselaer Polytechnic Institute, Vol. 7, No. 3, October 1999.
- R. Benoit, A. Deneyer, P. D’Herdt, and S. M. Diga, “Performance evaluation of dimmable lighting sources with fluorescent tubes for indoor applications,” Proceedings of International Lighting Symposium, Modern Quality Solutions for an Efficient Lighting, Sinaia, Romania, October 12–14, 2006
- L. Doulos, A. Tsangrassoulis, and F. Topalis, “Quantifying energy savings in daylight responsive systems: The role of dimming electronic ballasts,” Energy and Buildings, Vol. 40, No. 1, pp. 36–50, 2008.
- Commission internationale de l'éclairage, “The measurement of absolute luminous intensity distributions,” CIE Technical Report, No. 70, 1987.