A Novel Fuzzy—Adaptive Hysteresis Controller Based Three Phase Four Wire-Four Leg Shunt Active Filter for Harmonic and Reactive Power Compensation
- 1
- 2
Abstract
This paper presents a fuzzy logic based three phase four wire four-leg shunt active power filter to suppress harmonic currents. Modified instantaneous p-q theory is adopted for calculating the compensating current. Fuzzy-adaptive hysteresis band technique is applied for the current control to derive the switching signals for the voltage source inverter. A fuzzy logic controller is developed to control the voltage of the DC capacitor. Computer simulations are carried out on a sample power system to demonstrate the suitability of the proposed control strategy, for harmonic reduction under three different conditions namely, ideal, unbalance, unbalance and distorted source voltage conditions. The proposed control strategy is found to be effective to reduce the harmonics and compensate reactive power and neutral current and balance load currents under ideal and non-ideal source voltage conditions.
- B. Singh, K. Al Haddad and A. Chandra, “A Review of Active Filters for Power Quality Improvement,” IEEE Trans on Industrial Electronics, Vol. 46, No. 5, October 1999, pp. 960-970. doi:10.1109/41.793345
- L. Asiminoaei, Fr. Blaabjerg and S. Hansen, “Evaluation of Harmonic Detection Methods for Active Power Filter Applications,” Applied Power Electronics Conference, Vol. 1, March 2005, pp. 635-641.
- K. G. Firouzjah, A. Sheikholeslami, M. R. Karami-Mollaei and F. Heydari, “A Predictive Current Control method for Shunt Active Filter with Windowing Based Wavelet Transform in Harmonic Detection,” Simulation Modelling Practice and Theory, Vol. 17, No. 1, 2009, pp. 883-896. doi:10.1016/j.simpat.2009.02.008
- L. S Czarnecki, “On some Misinterpretations of the Instantaneous Reactive Power p-q Theory,” IEEE Transaction on Power Electronics, Vol. 19, No. 3, 2003, pp. 828-836.
- J. Afonso, C. Couto and J. Martins, “Ative Filters with Control Based on the p-q Theory,” IEEE Industrial Electronics Society Newsletter, Vol. 47, No. 3, 2000, pp. 5-10.
- Z. Salam, T. P. Cheng and A. Jusoh, “Harmonics Mitigation Using Active Power Filter: A Technological Review,” Elekrika, Vol. 8, No. 2, 2006, pp. 17-26.
- H. Akagi, E. H. Watanabe and M. Aredes, “The P-Q Theory for Active Fiter Control:Some Problems and Solutions,” Revista Controle & Automacao, Vol. 15, No. 1, 2004, pp. 945-970.
- H. Abaali, M. T. Lamchich and M. Raoufi, “The Three Phase Shunt Active Fiters for the Harmonics Compensation under Distorted and Unbalanced Mains Voltage Conditions,” IEEE International Conference on Industrial Technology (ICIT), Vol. 1, 2004, pp. 558-563.
- K. G. Firouzjaz, A. Sheikholeslami, M. R. Karami and F.Heydari, “Predictive Current Control Method for Shunt Active Filter with Windowing Based Wavelet Transform in Harmonic Detection,” Simulation Modelling Practice and Theory, Vol. 17, No. 1, 2009, pp. 883-896. doi:10.1016/j.simpat.2009.02.008
- M. S. A. Al-Haddad, F. Fnaiech and L. A. Dessaint, “Sliding Mode Control of 3-Phase 3-Wire Phase Shunt Active Filter in the dq Frame,” IEEE Proceedings, Vol. 2, 2001, pp. 765-769.
- J. Rodriguez, J. Ponti, C. Silva, S. Kouro, A. Liendo and J. Rebolleo, “Hysteresis Current Control and DTC: An Assessment,” International Journal of Electronics, Vol. 91, No. 11, 2004, pp. 639-651. doi:10.1080/00207210412331332871
- M. Kale, E. Ozdemir, “An Adaptive Hysteresis Band Current Controller for Shunt Active Power Filter,” Electrical Power and Energy Systems, Vol. 73, No. 2, 2005, pp. 113-119.