Analysis of Non-Sinusoidal Steady Electric Field of ±500 kV Converter Transformer
- 1 Hebei Provincial Key Laboratory of Power Transmission Equipment Security Defense, North China Electric Power Universi-ty, Baoding, China
- 2 Hebei Provincial Key Laboratory of Power Transmission Equipment Security Defense, North China Electric Power Universi-ty, Baoding, China
- 3 Hebei Provincial Key Laboratory of Power Transmission Equipment Security Defense, North China Electric Power Universi-ty, Baoding, China
- 4 Hebei Provincial Key Laboratory of Power Transmission Equipment Security Defense, North China Electric Power Universi-ty, Baoding, China
- 5 Hebei Provincial Key Laboratory of Power Transmission Equipment Security Defense, North China Electric Power Universi-ty, Baoding, China
- 6 State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China
- 7 Shandong Power Equipment Co., Ltd., Jinan, China
Abstract
The line side winding is under the fundamental frequency AC voltage, while the valve side winding contains not only fundamental AC voltage component, but also the DC voltage component, fundamental AC voltage component, and higher harmonic voltage components when the converter transformer is at its normal operating condition, and the electric field of converter transformer is a non-sinusoidal steady one. To analyze the non-sinusoidal steady electric field containing the DC component, fundamental AC and higher harmonic components, the voltage spectrum of the valve winding in a ±500 kV converter transformer is firstly analyzed, and the non-sinusoidal periodic steady electric field is obtained by the fast discrete Fourier transform. Different resistivity of the oil and oil-immersed paper is adopted to simulate the aging of oil paper insulation at operation, and get the non-sinusoidal steady electric field.
- Zhao, W.J. (2004) HVDC Engineering Technology. China Electric Power Press, Beijing, 318-325.
- Wang, C.L. and Li, J.H. (2005) Calculation and Analysis of End Electrical Field in Valve Winding Polarity Reverser Test for Converter Transformer. Transformer, 42, 11-14.
- Kurita, A., Takahashi, E., Ozawa, J., et al. (1983) DC Flashover Voltage Characteristics and Their Calculation Method for Oil-Immersed Insulation Systems in HVDC Transformers. IEEE Transactions on Power Delivery, PWRD-1, 184-190.
- Lv, X.D. and Chen, D.L. (1997) TheStudy on Electric Field Characteristics of Converter Transformer under Polarity Reversal. High Voltage Engineering, 23, 67-72.
- Zhang, Y.L. and Xie, D.X. (2001) Analysis of Transient Electric Field in Converter Transformer. Journal of Shenyang University of Technology, 23, 467-470.
- Li, J., Luo, L.F., Xu, J.Z., et al. (2016) Study on Electric Charateristics at Ends of Valve Side Winding in Converter Transformer. High Voltage Engineering, 32, 121- 214.
- Chen, Q.G., Zhang, J., Gao, Y., et al. (2008) Analysis of Complex Electric Field on Valve Side Widing of Converter transformer. High Voltage Engineering, 34, 484- 488.
- Ding, Z.G., Li, G.F., Li, P., et al. (2008) Electric Field Characteristic Calculation on Typical Oil-Paper Combination Insulation under Polarity Reversal. Power System Technology, 32, 82-85, 90.
- Zhang, X.L., Wang, J.M., Wu, Z.B, et al.(2009) Numerical Analysis of Electric Field in Valve Side Lead-out Wire for UHV DC Converter Transformer. Transformer, 46, 1-4, 10.
- Liu, P., Peng, Z.R., Dang, Z.P., et al. (2009) Study on Electric Field Distribution of ±800kV Converting Transformer Bushing Outlet Terminal during Polarity Reversal Test. Insulators and Surge Arresters, 3, 1-4, 8.
- Fu, T.J., Wang, J., Zhong, J.T., et al. (2009) Insulation Structure Analysis of ±800kV Converter Transformer for DC Transmission. Transformer, 46, 1-5.
- Zhang, Y.B., Zheng, J., Wang, D.H., et al. (2010) Development of UHVDC Converter Transformer. High Voltage Engineering, 36, 255-264.
- Liu, G., Li, L., Li, W.P., et al. (2012) Analysis of Nonlinear Electric Field of Converter Transformer under Polarity Reversal Voltage. High Voltage Engineering, 38, 451-456.
- Li, Y., Li X.H., Tang, C., et al. (2012) Analysis on Transient Electric Field at Ends of Valve-Side Winding in Converter Transformer. High Voltage Engineering, 38, 2797-2804.