Online Loss Parameters Diagnosis Device Development of Power Cable Insulation
- 1 State Grid Jiangsu Electric Power Research Institute, Nanjing, China
- 2 State Grid Jiangsu Electric Power Research Institute, Nanjing, China
- 3 State Grid Jiangsu Electric Power Research Institute, Nanjing, China
- 4 State Grid Jiangsu Electric Power Research Institute, Nanjing, China
- 5 State Grid Jiangsu Electric Power Research Institute, Nanjing, China
Abstract
In southern China, power cable lines often running in water, and the state of XLPE insulation is difficult to detection effectively. This paper studied loss parameters online diagnosis technology of power cable insulation. An online loss parameters diagnosis device was development, which consists of current comparator, voltage controlled current source (VCCS), standard capacitor, GPRS wireless transmission system, control system and the data processing unit. 108 cables were detected using this device, and it was found out that one cable appeared to middle aging and eight cables appeared to slight aging. The butterfly water trees were observed in middle aging cable, which prove the effectiveness of online testing in the loss current measurement.
- Faifer, M., Toscani, S., Ottoboni, R. (2011) Electronic Combined Transformer for Power-Quality Measurements in High-Voltage Systems. IEEE Transactions on Instrumentation & Measurement.
- Kosakada, M., Watanabe, H., Ito, T., et al. (2002) Integrated Substation Systems- Harmonizing Primary Equipment with Control and Protection Systems. Transmission and Distribution Confe-rence and Exhibition Asia Pacific. IEEE/PESIEEE, 2, 1020-1025.
- Hirotsu, K. (1994) Development of Hot-Line Diagnosis Method for XLPE Cables by Measurement of Harmonics Current. Proceedings of 1994 International Joint Conference: 26th Symposium on Electrical Insulation Materials, Osaka, 455-458.
- Moreau, E., Mayoux, C. and Laurent, C. (1993) The Structure Characteristics of Water Trees in Power Cables and Laboratory Specimens. IEEE Trans. on EI, 1, 54- 64.
- Shen, B.H. (2010) Investigation of Localized Production of HV Insulation Compound. Electric Wire and Cable, 1.
- Wei, X.L., Zhu, B., Pang, B., Wang, S. and Li, R.H. (2015) On-Line Insulation Monitoring Method for Long Distance Three-Phase Power Cable. Proceedings of the Chinese Electrical Engineering Science, 35.
- Yagi, Y., Tanaka, H. and Kimura, H. (1998) Study on Diagnostic Method for XLPE Cable by Harmonicsin Loss Current. Electrical Insulation and Dielectric Phenomena, 653-656.
- Tanaka, A., Yagi, Y. and Tanaka, H. (2003) On-Site Diagnostic Method for Water Treed XLPE Cable by Harmonics in AC Loss Current. Electrical Insulation NewNews in Asia, 10, 29-30.