Research ArticleOpen AccessGoogle Scholar indexed
Calculating Size of Pump-Hydro Combined Energy Storage System in Wind-Diesel Systems Based on PHCES Dynamic Model
Department of Electronic and Electrical Engineering, University of Strathclyde, Glasgow, United Kingdom
Department of Electronic and Electrical Engineering, University of Strathclyde, Glasgow, United Kingdom
Department of Electronic and Electrical Engineering, University of Strathclyde, Glasgow, United Kingdom
- 1 Department of Electronic and Electrical Engineering, University of Strathclyde, Glasgow, United Kingdom
- 2 Department of Electronic and Electrical Engineering, University of Strathclyde, Glasgow, United Kingdom
- 3 Department of Electronic and Electrical Engineering, University of Strathclyde, Glasgow, United Kingdom
Energy and Power Engineering·Volume 09 (2017)·Pages 224–231·Published 6 April 2017·DOI10.4236/epe.2017.94B027
Copy link · social · email
Abstract
This paper will propose an approach to calculate and evaluate the reserve capacity and energy size of Pumping-Hydro Combined Energy Storage (PHCES) when wind power is integrated to power grid while considering the scheme of generation capacity allocation and operation of PHCES. This approach will use Monte Carlo Method to simulate large amount of samples to obtain the minimum value of capacity and energy size that could satisfy the requirement of system reliability. Finally this approach will apply in a RBTS system to assess the project feasibility.
KeywordsWind PowerPHCESOperation of PHCESReliability
- (2009) Department of Energy and Climate Change.UK Renewable Energy Strategy, London.
- Saidur,R., et al. (2010)Areview on Global Wind Energy Policy. Renewable and Sustainable Energy Reviews, 14, 1744-1762.https://doi.org/10.1016/j.rser.2010.03.007
- Chowdhury, A.A., Zhang, Y. andAl,E.(2009) Practice of Large Wind Generation Interconnection Study in CAISO.IEEE PES 2009 General Meeting.
- Allan,R. (1994) Power System ReliabilityAs-sessment-A Conceptual and Historical Review. Reliability Engineering & System Safety, 46, 3-13. https://doi.org/10.1016/0951-8320(94)90043-4
- Baring-Gould,I. andDabo,M.(2009) Technology, Performance, and Market Re-port of Wind Diesel Applications for Remote and Island Communities. National Renewable Energy Laboratory (NREL).
- (2009) Impact of increased DFIG Wind Penetration on Power System and Markets. Power System Engineering Research Cen-ter.
- Papaefthymiou, G. and Klockl, B. (2008) MCMC for Wind Power Simulation IEEE trans. Energy Convers., 234-240
- Hegazy, Y.G., Salama, M.M.A. and Chikhani A.Y.(2003) Adequacy Assessment of Distributed Generation Systems Using Monte Carlo Simulation, IEEE Trans. Power System, 48-52.https://doi.org/10.1109/TPWRS.2002.807044
- Wang, S., et al.(2016) An Approach to Calculate the Capacity of Pump-Hydro Combined Energy Storage with Wind Power Integration. World Journal of Engineering and Technology, 43-49
- Billinton, R. and Allan R.N. (1996) Reliability Evaluation of Enginerring Sys-tems.
- Billinton, R. (1989) A reliability Test System for Educational Purposes-Basic Data. Power Systems, IEEE Transactions on, 1238-1244.