The cooling and heating of spaces are among the largest sources for household’s energy demand. Ground Source Heat Pump (GSHP) is a promising technology to reduce the energy for cooling and heating purposes. However, the major obstacle hindering the utilization of this technology is the high initial cost, especially for the installation of ground coupled heat exchanger. The horizontal closed-loop system offers lower installation cost, as it requires no vertical borehole construction. Instead, the heat exchangers can be installed in shallow trenches that may be excavated, by small excavator or even by hu man labor. This paper presents the comparison of two different heat exc hangers, namely, the capillary mat and the widely used slinky pipe. Both heat exchangers are connected to a heat pump, where continuous heating tests were carried out for 165 hours (~7 days) for each configuration. The purpose of this research is to show the performance of capillary mat in comparison to slinky pipe. Despite during the entire test for capillary mat required 6% higher electricity consumption, compared to slinky heat exchanger, the results still suggest the potential use of capillary mat as alternative to slinky heat exchanger. Additionally, the results also highlight the high hydraulic resistance of installed capillary mat heat exchangers may become the major disadvantage of the capillary mat.
KeywordsHorizontal Heat ExchangerGround Source Heat PumpCapillary Mat
Sivasakthivel, T., Murugesan, K. and Sahoo, P.K. (2014) A Study on Energy and CO2 Saving Potential of Ground Source Heat Pump System in India. Renewable and Sustainable Energy Reviews, 32, 278-293. https://doi.org/10.1016/j.rser.2014.01.031
Bayer, P., Saner, D., Bolay, S., Rybach, L. and Blum, P. (2012) Greenhouse Gas Emission Savings of Ground Source Heat Pump Systems in Europe: A Review. Renewable and Sustainable Energy Reviews, 16, 1256-1267. https://doi.org/10.1016/j.rser.2011.09.027
Genchi, Y., Kikegawa, Y. and Inaba, A. (2002) CO2 Payback-Time Assessment of a Regional-Scale Heating and Cooling System Using a Ground Source Heat-Pump in a High Energy-Consumption Area in Tokyo. Applied Energy, 71, 147-160. https://doi.org/10.1016/S0306-2619(02)00010-7
Kikegawa, Y., Genchi, Y., Kondo, H. and Hanaki, K. (2006) Impacts of City-Block-Scale Countermeasures against Urban Heat-Island Phenomena upon a Building’s Energy-Consumption for Air-Conditioning. Applied Energy, 83, 649-668. https://doi.org/10.1016/j.apenergy.2005.06.001
Kardinal Jusuf, S., Wong, N.H., Hagen, E., Anggoro, R. and Hong, Y. (2007) The Influence of Land Use on the Urban Heat Island in Singapore. Habitat International, 31, 232-242. https://doi.org/10.1016/j.habitatint.2007.02.006
Arifwidodo, S. and Chandrasiri, O. (2015) Urban Heat Island and Household Energy Consumption in Bangkok, Thailand. Energy Procedia, 79, 189-194. https://doi.org/10.1016/j.egypro.2015.11.461
Garber, D., Choudhary, R. and Soga, K. (2013) Risk Based Lifetime Costs Assessment of a Ground Source Heat Pump (GSHP) System Design: Methodology and Case Study. Building and Environment, 60, 66-80. https://doi.org/10.1016/j.buildenv.2012.11.011
Zhu, Y., Tao, Y. and Rayegan, R. (2012) A Comparison of Deterministic and Probabilistic Life Cycle Cost Analyses of Ground Source Heat Pump (GSHP) Applications in Hot and Humid Climate. Energy and Buildings, 55, 312-321. https://doi.org/10.1016/j.enbuild.2012.08.039
Sriamonkul, W., Intarajinda, R., Tongsuk, N. and Saengsuwan, S. (2011) Life Cycle Cost Analysis of Air Conditioning System for Residential Sector in Thailand. GMSARN International Journal, 5, 131-138.
Park, N., Jung, S., Park, H., Choi, H., Chin, S. and Jung, H. (2010) Payback Period Estimation of Ground-Source and Air-Source Multi Heat Pumps in Korea Based on Yearly Running Cost Simulation. International Refrigeration and Air Conditioning Conference.
Widiatmojo, A., Chokchai, S., Takashima, I., Uchida, Y., Yasukawa, K., Chotpantarat, S. and Charusiri, P. (2019) Ground-Source Heat Pumps with Horizontal Heat Exchangers for Space Cooling in the Hot Tropical Climate of Thailand. Energies, 12, 1274. https://doi.org/10.3390/en12071274
Mustafa Omer, A. (2008) Ground-Source Heat Pumps Systems and Applications. Renewable and Sustainable Energy Reviews, 12, 344-371. https://doi.org/10.1016/j.rser.2006.10.003
Wu, R., Tinjum, J.M. and Likos, W.J. (2015) Coupled Thermal Conductivity Dryout Curve and Soil-Water Characteristic Curve in Modeling of Shallow Horizontal Geothermal Ground Loops. Geotechnical and Geological Engineering, 33, 193-205. https://doi.org/10.1007/s10706-014-9811-2
Chalhoub, M., Bernier, M., Coquet, Y. and Philippe, M. (2017) A Simple Heat and Moisture Transfer Model to Predict Ground Temperature for Shallow Ground Heat Exchangers. Renewable Energy, 103, 295-307. https://doi.org/10.1016/j.renene.2016.11.027
Wu, Y., Gan, G., Verhoef, A., Vidale, P.L. and Gonzalez, R.G. (2010) Experimental Measurement and Numerical Simulation of Horizontal-Coupled Slinky Ground Source Heat Exchangers. Applied Thermal Engineering, 30, 2574-2583. https://doi.org/10.1016/j.applthermaleng.2010.07.008
Xiong, Z., Fisher, D.E. and Spitler, J.D. (2015) Development and Validation of a SlinkyTM Ground Heat Exchanger Model. Applied Energy, 141, 57-69. https://doi.org/10.1016/j.apenergy.2014.11.058
Zhou, G. and He, J. (2015) Thermal Performance of a Radiant Floor Heating System with Different Heat Storage Materials and Heating Pipes. Applied Energy, 138, 648-660. https://doi.org/10.1016/j.apenergy.2014.10.058
Xia, Y. and Zhang, X.S. (2016) Experimental Research on a Double-Layer Radiant Floor System with Phase Change Material under Heating Mode. Applied Thermal Engineering, 96, 600-606. https://doi.org/10.1016/j.applthermaleng.2015.11.133
Hu, R. and Niu, J.L. (2012) A Review of the Application of Radiant Cooling & Heating Systems in Mainland China. Energy and Buildings, 52, 11-19. https://doi.org/10.1016/j.enbuild.2012.05.030
Carbonell, D., Battaglia, M., Philippen, D. and Haller, M.Y. (2018) Numerical and Experimental Evaluation of Ice Storages with Ice on Capillary Mat Heat Exchangers for Solar-Ice Systems. International Journal of Refrigeration, 88, 383-401. https://doi.org/10.1016/j.ijrefrig.2018.02.007
Zhao, M., Kang, W., Luo, X., Yu, C.W., Meng, X.Z. and Gu, Z. (2017) Performance Comparison of Capillary Mat Radiant and Floor Radiant Heating Systems Assisted by an Air Source Heat Pump in a Residential Building. Indoor and Built Environment, 26, 1292-1304. https://doi.org/10.1177/1420326X16674517
Echarri, V. (2017) Demand-Oriented Design Strategies for Low Environmental Impact Housing in the Tropics. Sustainability, 9, 1614. https://doi.org/10.3390/su9091614
Yafan, H., Chao, F., Yangyang, D., Xingqiao, J., Sukun, P. and Caijie, L. (2014) Building Energy System Based on Capillary Mats. Electronic Journal of Geotechnical Engineering, 19, 17627-17634.
Renewable Research Center (2019) SORA Weather Data. https://www.renewable.pr.aist.go.jp/ent/en/past_frea_en
Selamat, S., Miyara, A. and Kariya, K. (2016) Numerical Study of Horizontal Ground Heat Exchangers for Design Optimization. Renewable Energy, 95, 561-573. https://doi.org/10.1016/j.renene.2016.04.042
Esen, H., Inalli, M. and Esen, M. (2007) Numerical and Experimental Analysis of a Horizontal Ground-Coupled Heat Pump System. Building and Environment, 42, 1126-1134. https://doi.org/10.1016/j.buildenv.2005.11.027
Li, C., Cleall, P.J., Mao, J. and Munoz-Criollo, J.J. (2018) Numerical Simulation of Ground Source Heat Pump Systems Considering Unsaturated Soil Properties and Groundwater Flow. Applied Thermal Engineering, 139, 307-316. https://doi.org/10.1016/j.applthermaleng.2018.04.142
Gan, G. (2018) Dynamic Thermal Performance of Horizontal Ground Source Heat Pumps—The Impact of Coupled Heat and Moisture Transfer. Energy, 152, 877-887. https://doi.org/10.1016/j.energy.2018.04.008