Nonlinear Switching Transient Field Simulation of Cable Joint without Residual Charge
- 1 Guagnzhou Power Supply CSG, Guangzhou, China
- 2 Guagnzhou Power Supply CSG, Guangzhou, China
- 3 Guagnzhou Power Supply CSG, Guangzhou, China
- 4 Guagnzhou Power Supply CSG, Guangzhou, China
- 5 Guagnzhou Power Supply CSG, Guangzhou, China
- 6 Guagnzhou Power Supply CSG, Guangzhou, China
- 7 Guagnzhou Power Supply CSG, Guangzhou, China
- 8 Guagnzhou Power Supply CSG, Guangzhou, China
- 9 Department of Electrical and Electronic Engineering, North China Electric Power University, Beijing, China
- 10 Department of Electrical and Electronic Engineering, North China Electric Power University, Beijing, China
- 11 Department of Electrical and Electronic Engineering, North China Electric Power University, Beijing, China
- 12 Department of Electrical and Electronic Engineering, North China Electric Power University, Beijing, China
Abstract
The analysis of the impulse voltage on the internal electric field of the cable joint plays a key role in studying the breakdown of the joint. Based on the finite element method, a three-dimensional electromagnetic field simulation model of the cable joint is established in this paper. Simulation results show that the voltage at the head of the cable joint reaches about twice the impulse voltage. The increase of the conductivity of semi-conductive material also leads to the increase of electric field intensity. Then, several points and curves at different positions are selected for further analysis in this paper. Among them, the electric field distortion at the edge of the high voltage shield is the most serious and the electric field in the air gap is the least.
- Mazzanti, G., Montanari, G.C., and Palmieri, F. (2003) Quantities Extracted from Space-charge Measurements as Markers for Insulation Aging. IEEE Transactions on Dielectrics and Electrical Insulation, 10, 198-203. http://dx.doi.org/10.1109/TDEI.2003.1194100
- Tohmine, T., Fujitomi, T., Miyake, H., Tanaka, Y., Ida, Y. and Inoue, Y. (2017) Measurement of Space Charge Accumulated in Multi-layered Samples Composed of Different Insulators Used in the Joints of DC Transmission Cables. 2017 International Symposium on Electrical Insulating Materials (ISEIM), Toyohashi, 2017, 299-302. http://dx.doi.org/10.23919/ISEIM.2017.8088746
- Yaroslavskiy, V., Walker, M., Katz, C. and Keefe, R. (2008) Comparative Laboratory Evaluation of Premolded Joints for Medium Voltage Cables. IEEE Transactions on Power Delivery, 23, 516-522. http://dx.doi.org/10.1109/TPWRD.2007.915909
- Aoran, X. and Yueping, M. (2019) Research Status and Trend of Insulation State Detection Technology for Power Cable Joints. Science and Technology Innovation and Application, 31, 28-31.
- Guo, Q., Xiong, J., Dai, N., Liao, S. and Lu, B. (2018) Influence of the Material Parameters on the Electric Field Intensity Distribution of 10kV Cable Elbow Connector. 2018 2nd IEEE Conference on Energy Internet and Energy System Integration (EI2), Beijing, 2018, 1-5. http://dx.doi.org/10.1109/EI2.2018.8582320
- Heinrich, R., Bonisch, S., Pommerenke, D., Jobava, R. and Kalkner, W. (2000) Broadband Measurement of the Conductivity and the Permittivity of Semiconducting Materials in High Voltage XLPE Cables. 2000 Eighth International Conference on Dielectric Materials, Measurements and Applications (IEE Conf. Publ. No. 473), Edinburgh, 2000, 212-217. http://dx.doi.org/10.1049/cp:20000507