A neural network-based infection screening system that uses vital signs and percutaneous oxygen saturation for rapid screening of patients with influenza
- 1 Graduate School of System Design, Tokyo Metropolitan University, Tokyo, Japan;
- 2 Department of Internal Medicine, Japan Self-Defense Forces Central Hospital, Tokyo, Japan
- 3 Takasaka Clinic, Fukushima, Japan
- 4 Lifetech Co., Ltd., Saitama, Japan
- 5 Graduate School of System Design, Tokyo Metropolitan University, Tokyo, Japan;
Abstract
Objective: Influenza is a highly infectious viral disease, which occurs epidemically almost every winter in Japan. Rapid screening of patients with suspected influenza in places of mass gathering is important to delay or prevent transmission of the infection. The aim of this study was to assess the effectiveness of our newly developed infection screening system that employed vital signs and percutaneous oxygen saturation (SpO 2 ) as parameters in a clinical setting. Methods: Since SpO 2 accurately reflects respiratory status during influenza virus infection, we upgraded our previous system by adding SpO 2 as a new parameter to improve the screening accuracy. This system instantly measures SpO 2 and vital signs ( i.e ., heart rate, respiration rate, and facial temperature), which automatically detects infected individuals via a neural network-based nonlinear discriminant function using these derived parameters. We tested the system on 45 patients with seasonal influenza (35.8℃ < body temperature < 40.0℃, 18-35 years) and 64 normal control subjects (35.0℃ < body temperature < 37.5℃, 18-30 years) at Japan Self-Defense Central Hospital in 2012. Results: The system identified 40/45 patients with influenza and 60/64 normal control subjects, and provided sensitivity, specificity, and positive and negative predictive value (PPV, NPV) of 88.8%, 93.8%, 90.9%, and 92.3%, respectively. By including SpO 2 as a screening parameter, we achieved superior sensitivity and NPV compared to that reported in our previous paper (sensitivity = 88%; NPV = 82%). Conclusions: Our results suggest that SpO 2 is a good screening parameter that improves the accuracy of infection screening. The proposed system has the potential to efficiently identify infected individuals, thereby delaying or preventing the spread of infection during epidemic seasons.
- Chou, Gao, R., Cao, B., Hu, Y., Feng, Z., Wang, D., Hu, W. and Shu, Y. (2013) Human infection with a novel avianorigin influenza A (H7N9) virus. The New England Journal of Medicine, 368, 1888-1897. doi:10.1056/NEJMoa1304459
- Rello, J. and Pop-Vicas, A. (2009) Clinical review: Primary influenza viral pneumonia. Critical Care, 13, 235. doi:10.1186/cc8183
- Wentworth, D.E., Thompson, B.L., Xu, X., Regnery, H. L., Cooley, A.J., McGregor, M.W. and Hinshaw, V.S. (1994) An influenza A (H1N1) virus, closely related to swine influenza virus, responsible for a fatal case of human influenza. Journal of Virology, 68, 2051-2058.
- Chiang, M.F., Lin, P.W., Lin, L.F., Chiou, H.Y., Chien, C. W., Chu, S.F. and Chiu, W.T. (2008) Mass screening of suspected febrile patients with remote-sensing infrared thermography: Alarm temperature and optimal distance. Journal of the Formosan Medical Association, 107, 937-944. doi:10.1016/S0929-6646(09)60017-6
- Hay, A.D., Peters, T.J., Wilson, A. and Fahey, T. (2004) The use of infrared thermometry for the detection of fever. The British Journal of General Practice, 54, 448-450.
- Nishiura, H. and Kamiya, K. (2011) Fever screening during the influenza (H1N1-2009) pandemic at Narita International Airport, Japan. BMC Infectious Diseases, 11, 111. doi:10.1186/1471-2334-11-111
- Liu, C.C., Chang, R.E. and Chang, W.C. (2004) Limitations of forehead infrared body temperature detection for fever screening for severe acute respiratory syndrome. Infection Control and Hospital Epidemiology, 25, 1109-1111. doi:10.1086/502351
- Chan, L. S., Cheung, G. T., Lauder, I. J., and Kumana, C. R. (2004) Screening for fever by remote-sensing infrared thermographic camera. J Travel Med, 11(5), 273-279. doi:10.2310/7060.2004.19102
- Matsui, T., Hakozaki, Y., Suzuki, S., Usui, T., Kato, T., Hasegawa, K. and Abe, S. (2010) A novel screening method for influenza patients using a newly developed noncontact screening system. Journal of Infection, 60, 271-277. doi:10.1016/j.jinf.2010.01.005
- Matsui, T., Suzuki, S., Ujikawa, K., Usui, T., Gotoh, S., Sugamata, M. and Abe, S. (2009) The development of a non-contact screening system for rapid medical inspection at a quarantine depot using a laser Doppler bloodflow meter, microwave radar and infrared thermography. Journal of Medical Engineering & Technology, 33, 481-487. doi:10.1080/03091900902952675
- Bewick, Thomas, B., Greenwood, S. and Lim, W.S. (2010) What is the role of pulse oximetry in the assessment of patients with community-acquired pneumonia in primary care? Primary Care Respiratory Journal, 19, 378-382. doi:10.4104/pcrj.2010.00049