Liquid Crystal Biosensor Based on Cd<sup>2+</sup> Inducing the Bending of PS-Oligo for the Detection of Cadmium
- 1 Laboratory of Biomedical Engineering, Chongqing Medical University, Chongqing, China
- 2 Laboratory of Biomedical Engineering, Chongqing Medical University, Chongqing, China
- 3 Laboratory of Biomedical Engineering, Chongqing Medical University, Chongqing, China
- 4 Laboratory of Biomedical Engineering, Chongqing Medical University, Chongqing, China
- 5 Experimental Teaching Management Center, Chongqing Medical University, Chongqing, China
Abstract
In this study, a novel liquid crystal (LC) biosensor was developed for the highly sensitive and selective detection of Cd 2+ based on Cd 2+ inducing the bending of PS-oligo. This strategy makes use of the DNA conformational change to enhance the disruption of orientation of LC leading to an amplified optical signal. DNA containing-SH was bound on the glass slide of the LC cell modified with the DMOAP/APTES. The DMOAP can effectively induce the homeotropic alignment of LC. In the presence of Cd 2+ , Cd 2+ can induce DNA to bend and become a 2 nm spherical structure, which can greatly disrupt the orientational arrangement of LC, resulting in the correspond changes of the optical image of LC cell birefringent under the polarizing microscope. When the Cd 2+ concentration is low to 0.1 nM, the optical signal of LC biosensor has an obvious change. But in the absence of Cd 2+ , there is no orientational response of LC and the optical image under the polarizing microscope is still a uniform dark background. Thus, this LC sensing method has a sensitive and clear distinction between positive and negative results and offers a highly sensitive detection of Cd 2+ with a low detection limit down to 0.1 nM.
- Aragay, G., Pons, J. and Merkoci, A. (2011) Recent Trends in Macro-, Micro-, and Nanomaterial-Based Tools and Strategies for Heavy-Metal Detection. Chemical Reviews, 111, 3433-3458. http://dx.doi.org/10.1021/cr100383r
- Aragay, G. and Merkoci, A. (2012) Nanomaterials Application in Electrochemical Detection of Heavy Metals. Electrochim Acta, 84, 49-61. http://dx.doi.org/10.1016/j.electacta.2012.04.044
- Zakir, H.S.M. and Brennan, J.D. (2011) β-Galactosidase-Based Colorimetric Paper Sensor for Determination of Heavy Metals. Analytical Chemistry, 83, 8772-8778. http://dx.doi.org/10.1021/ac202290d
- Bhagure, R.G. and Mirgane, S.R. (2011) Heavy Metal Concentrations in Groundwaters and Soils of Thane Region of Maharashtra, India. Environmental Monitoring and Assessment, 173, 643-652. http://dx.doi.org/10.1007/s10661-010-1412-9
- Khosraviani, M., et al. (1998) Detection of Heavy Metals by Immunoassay: Optimization and Validation of a Rapid, Portable Assay for Ionic Cadmium. Environmental Science & Technology, 32, 137-142. http://dx.doi.org/10.1021/es9703943
- Darwish, I.A. and Blake, D.A. (2001) One-Step Competitive Immunoassay for Cadmium Ions: Development and Validation for Environmental Water Samples. Analytical Chemistry, 73, 1889-1895. http://dx.doi.org/10.1021/ac0012905
- Darwish, I.A. and Blake, D.A. (2002) Development and Validation of a One-Step Immunoassay for Determination of Cadmium in Human Serum. Analytical Chemistry, 74, 52-58. http://dx.doi.org/10.1021/ac010510r
- Guell, R., et al. (2008) Sensitive and Stable Monitoring of Lead and Cadmium in Seawater Using Screen-Printed Electrode and Electrochemical Stripping Analysis. Analytica Chimica Acta, 627, 219-224. http://dx.doi.org/10.1016/j.aca.2008.08.017
- Malekpour, A., Hajialigol, S. and Taher, M.A. (2009) Study on Solid-Phase Extraction and Flame Atomic Absorption Spectrometry for the Selective Determination of Cadmium in Water and Plant Samples with Modified Clinoptilolite. Journal of Hazardous Materials, 172, 229-233. http://dx.doi.org/10.1016/j.jhazmat.2009.06.163
- Matsumoto, A., et al. (2010) Determination of Cadmium by an Improved Double Chamber Electrothermal Vaporization Inductively Coupled Plasma Atomic Emission Spectrometry. MicroChem, 95, 85-89. http://dx.doi.org/10.1016/j.microc.2009.10.012
- Guo, W., Hu, S.H., Xiao, Y.F., Zhang, H.F. and Xie, X.J. (2010) Direct Determination of Trace Cadmium in Environmental Samples by Dynamic Reaction Cell Inductively Coupled Plasma Mass Spectrometry. Chemosphere, 81, 1463-1468. http://dx.doi.org/10.1016/j.chemosphere.2010.08.056