Availability of Heat Conduction for Environmental Control Method to Improving Thermal Environment and Preventing Oversensitivity to Cold and Air-Conditioning Disease on Female Office Workers — Oak Academic Publishing
Research ArticleOpen AccessGoogle Scholar indexed
Availability of Heat Conduction for Environmental Control Method to Improving Thermal Environment and Preventing Oversensitivity to Cold and Air-Conditioning Disease on Female Office Workers
School of Life Studies, Sugiyama Jogakuen University, Nagoya, Japan
,
Department of Architecture, Ariake National College of Technology, Omuta, Japan
,
Department of Architecture, Kyushu Sangyo University, Fukuoka, Japan
,
School of Life Studies, Sugiyama Jogakuen University, Nagoya, Japan
,
Department of Architecture and Structural Engineering, Kure National College of Technology, Kure, Japan
,
School of Humanities and Social Sciences, Osaka Prefecture University, Sakai, Japan
,
Kansei Engineering Course, Shinshu University, Ueda, Japan
,
School of Human Science & Environment, University of Hyogo, Himeji, Japan
,
Department of Architecture, Aichi Sangyo University, Okazaki, Japan
1 School of Life Studies, Sugiyama Jogakuen University, Nagoya, Japan
2 Department of Architecture, Ariake National College of Technology, Omuta, Japan
3 Department of Architecture, Kyushu Sangyo University, Fukuoka, Japan
4 School of Life Studies, Sugiyama Jogakuen University, Nagoya, Japan
5 Department of Architecture and Structural Engineering, Kure National College of Technology, Kure, Japan
6 School of Humanities and Social Sciences, Osaka Prefecture University, Sakai, Japan
7 Kansei Engineering Course, Shinshu University, Ueda, Japan
8 School of Human Science & Environment, University of Hyogo, Himeji, Japan
9 Department of Architecture, Aichi Sangyo University, Okazaki, Japan
The purpose of this study is to demonstrate the effect localized heating of the feet has on physiological and psychological reactions of female in an air-conditioned environment in summer. In Japan, female office workers wear less clothing than their male counterparts. In an air-conditioned office space in summer, female conducts thermoregulation by putting on cardigans, etc. but this action does not greatly contribute to improving conditions for the legs and feet, the lower extremities of the body. The improvement of sensational and physiological temperature by localized warming of the body can contribute to a healthy working environment for female office workers, their safety, and a reduction in air conditioning’s energy expenditure. We used the indoor thermal environment evaluation index ETF to investigate the effect localized heating of the feet has on human physiological and psychological response in an air-conditioned environment in summer. The result of heating by means of heat conduction via the sole of the foot was expressed more strongly as a psychological effect than as a whole-body physiological effect. Heating by means of heat conduction via the sole of the foot was a thermal environment factor that compensates for a low temperature in whole-body thermal sensation and whole-body thermal comfort. The effect of heating due to heat conduction via the sole of the foot was expressed in the change in sole-of- the-foot skin temperature. Applying slight heat conduction by means of heating via the sole of the foot demonstrated the result of improved whole-body thermal sensation and whole-body thermal comfort.
KeywordsFemaleOffice WorkerSensitivity to ColdThermal EnvironmentThermal Sense
Muncey, R.W. and Hutson, J.M. (1953) The Effect of the Floor on Foot Temperature. Australian Journal of Applied Science, 4, 395-404.
Missenard, A. (1955) Chauffage par Rayonnement Température Limite du Sol. Chaieuret Industrie, 355, 37-53.
Cammerer, J.S. and Schüle, W. (1957) Vergleichsmessungen zwischen physiologischen und physikalischen-prüfverffahren der warmeableitung von fubboden. Gesundheits Ingenieur, 78, 251-252.
Olesen, B.W. (1977) Thermal Comfort Requirements for Floors. Proceedings of the Meeting of Commissions B1, B2, E1 of the IIR, Belgrade, Yugoslavia, 16-18 November 1977, 337-343.
Olesen, B.W. (1977) Thermal Comfort Requirements for Floors Occupied by People with Bare Feet. ASHRAE Transactions, 83, 41-57.
Choi, Y., Horikoshi, T., Miyamoto, S. and Mizutani, A. (1996) Combined Effect of Air and Heated Floor Temperature on Man in Japanese Sitting Posture. Journal of Architecture, Planning and Environmental Engineering (Transactions of AIJ), 480, 7-14.
Watanabe, S., Horikoshi, T., Miyoshi, Y. and Miyamoto, S. (1997) Thermal Effect of Heating Lower Extremities of the Human Body Using Kotatsu on the Human Thermal Comfort. Journal of Architecture, Planning and Environmental Engineering (Transactions of AIJ), 497, 47-52.
Kurazumi, Y., Hamanaka, K. and Kobayashi, K. (2005) Optimum Thermal Comfort Zone in Floor Cooling Condition. Transactions of the Society of Heating, Air-Conditioning and Sanitary Engineers of Japan, 99, 31-41.
Kurazumi, Y. and Kobayashi, K. (2006) Thermal Comfort Zone in Floor Cooling. Transactions of the Society of Heating, Air-Conditioning and Sanitary Engineers of Japan, 114, 39-49.
Kurazumi, Y., Tsuchikawa, T., Kondo, E., Yamato, Y., Tobita, K., Fukagawa, K., Horikoshi, T. and Matsubara, N. (2009) Validity and Evaluation Method of Combined Thermal Environmental Factors upon the Human Body. Japanese Journal of Biometeorology, 46, 121-137.
Horikoshi, T., Dohi, M. and Tsuji, C. (1987) Experimental Study on the Influence of Thermal Conditions upon the Human Physiological and Psychological Responses in Air-Conditioned Room. The Annals of Physiological Anthropology, 6, 255-266. http://dx.doi.org/10.2114/ahs1983.6.255
Kurazumi, Y., Matsubara, N., Yamato, Y., Yamamoto, S., Nagai, H. and Narumi, D. (1998) The Influence of Posture upon Conductive Heat Exchange. Japanese Journal of Biometeorology, 35, 85-94.
Kurazumi, Y., Matsubara, N., Nagai, H., Furukawa, N., Fujiwara, M., Ue, A., Ueki, Y. and Yamamoto, S. (1999) The Effect of Conductive Heat Exchange for Evaluation of the Thermal Environment on the Human Body. Transactions of the Society of Heating, Air-Conditioning and Sanitary Engineers of Japan, 72, 23-34.
Kurazumi, Y., Matsubara, N., Ueki, Y., Ue, A., Nagai, H., Yamamoto, S., Furukawa, N. and Fujiwara, M. (1999) Influence of the Difference of Postures upon the Human Physiological and Phychological Responses in a Heated Floor Room. Japanese Journal of Biometeorology, 36, 3-19.
Kurazumi, Y., Tsuchikawa, T., Kondo, E., Horikoshi, T. and Matsubara, N. (2009) Conduction-Corrected Modified Effective Temperature as the Indices of Combined and Separate Effect of Environmental Factors on Sensational Temperature. Energy and Buildings, 42, 441-448. http://dx.doi.org/10.1016/j.enbuild.2009.10.012
Ministry of Health, Labour and Welfare in Japan (2016) The National Health and Nutrition Survey in Japan, 2012. http://www.mhlw.go.jp/bunya/kenkou/eiyou/dl/h24-houkoku.pdf
Ministry of Health, Labour and Welfare in Japan (2016) The National Health and Nutrition Survey in Japan, 2013. http://www.mhlw.go.jp/bunya/kenkou/eiyou/dl/h25-houkoku.pdf
Kurazumi, Y., Horikoshi, T., Tsuchikawa, T. and Matsubara, N. (1994) The Body Surface Area of Japanese. Japanese Journal of Biometeorology, 31, 5-29.
World Medical Association (2015) WMA Declaration of Helsinki—Ethical Principles for Medical Research Involving Human Subjects. http://www.wma.net/en/30publications/10policies/b3/index.html
Hanada, K., Mihira, K. and Ohhata, K. (1981) Studies on the Thermal Resistance of Women’s Underwear. Journal of the Japan Research Association for Textile End-Use, 22, 430-437.
Horikoshi, T., Kobayashi, Y. and Tsuchikawa, T. (1991) Indices of Combined and Independent Effect of Thermal Environmental Variable upon the Human Body. ASHRAE Transactions, 97, 228-238.
Kurazumi, Y., Tsuchikawa, T., Kakutani, K., Yamato, Y., Torii, T., Matsubara, N. and Horikoshi, T. (2004) Mean Skin Temperature Taking into Account Convective Heat Transfer Areas, -Calculation Method of Seiza Sitting, Cross- Legged Sitting, Sideway Sitting, Both-Knees-Erect Sitting, Leg-Out Sitting, Lateral and Supine Positions-. Journal of Environmental Engineering (Transactions of AIJ), 585, 19-26.
Kurazumi, Y., Matsubara, N., Furukawa, N., Fujiwara, M., Ue, A., Ueki, Y., Nagai, H. and Yamamoto, S. (1998) Japanese Weighting Coefficients for Calculating Mean Skin Temperature in Relation to Posture. Japanese Journal of Biometeorology, 35, 121-132.
Watanabe, S., Horikoshi, T., Miyoshi, Y., Miyamoto, S. and Mizutani, A. (1997) Thermal Effect of Heating Facility Kotatsu on the Human Body in Japanese Style Room. Journal of Architecture, Planning and Environmental Engineering (Transactions of AIJ), 497, 39-45.
Kurazumi, Y., Yamato, Y., Tobita, K., Fukagawa, K., Hase, H., Han, S., Kondo, E., Tsuchikawa, T., Horikoshi, T. and Matsubara, N. (2010) Experimental Verification of Conduction-Corrected Modified Effective Temperature as Thermal Environmental Evaluation Index. CLIMA 2010 (10th REHVA World Congress), Antalya, Turkey, 9-12 May 2010, 1-8.
Kurazumi, Y., Tsuchikawa, T., Matsubara, N. and Horikoshi, T. (2008) Effect of Posture on the Heat Transfer Areas of the Human Body. Building and Environment, 43, 1555-1565. http://dx.doi.org/10.1016/j.buildenv.2007.09.001
Hendler, E., Crosbie, R. and Hardy, J.D. (1958) Measurement of Heating of the Skin during Exposure to Infrared Radiation. Journal of Applied Physiology, 12, 177-185.
Tsuchikawa, T., Kobayashi, Y., Horikoshi, T., Miwa, E., Kurazumi, Y. and Hirayama, K. (1988) The Effective Radiation Area of the Human Body and Configuration Factors between the Human Body and Rectangular Planes and Measured by the Photographic Method, -Measurement for Male Subjects; Four Combinations of Nude or Closed and Standing or Sedentary Postures-. Journal of Architecture, Planning and Environmental Engineering (Transactions of AIJ), 388, 48-59.
Kurazumi, Y., Tsuchikawa, T., Yamato, Y., Sakoi, T., Bolashikov, Z.D., Kondo, E., Fukagawa, K., Tobita, K., Matsubara, N. and Horikoshi, T. (2013) Measurement of Heat Transfer Coefficients of Leg-Out Sitting and Chair Sitting Human Body under Forced Convection from Front and Back. Journal of Human and Living Environment, 20, 51-61.
Kuno, S., Ohno, H. and Nakahara, N. (1987) A Two-Dimensional Model Expressing Thermal Sensation in Transitional Condition. ASHRAE Transactions, 93, 396-406.
Isoda, N., Kobayashi, Y., Horikoshi, T. and Ikeda, N. (1975) Experimental Study on Effect of Air Velocity upon Human Body in Wind Tunnel: In Intermediate, Cooling and Heating Periods. Transactions of the Architecture Institute of Japan, 229, 121-128.