Intrahospital Dissemination of Automatic External Defibrillators Decrease Time to Defibrillation of In-Hospital Cardiac Arrests
- 1 Department of Cardiology, Center of Resuscitation and Science, Karolinska Institutet, S?dersjukhuset, Sweden
- 2 Department of Cardiology, Center of Resuscitation and Science, Karolinska Institutet, S?dersjukhuset, Sweden
- 3 Department of Cardiology, Center of Resuscitation and Science, Karolinska Institutet, S?dersjukhuset, Sweden
- 4 Section of Anaestethiology, Department of Clinical Science and Education, Karolinska Institutet, S?dersjukhuset, Sweden
- 5 Department of Cardiology, Center of Resuscitation and Science, Karolinska Institutet, S?dersjukhuset, Sweden
- 6 Department of Cardiology, Center of Resuscitation and Science, Karolinska Institutet, S?dersjukhuset, Sweden
- 7 Department of Cardiology, Center of Resuscitation and Science, Karolinska Institutet, S?dersjukhuset, Sweden
- 8 Department of Clinical Sciences, Danderyd Hospital, Karolinska Institutet, Stockholm, Sweden
Abstract
Background: Survival rates for in-hospital cardiac (IHCA) arrest are low. Early defibrillation is vital and international guidelines , which requests defibrillation within three minutes. Can dissemination of automatic external defibrillators (AED) at hospital wards shorten time to defibrillation compared to standard care, calling for medical emergency team (MET)? Material & Methods: Forty-eight (48) units at S ? dersjukhuset, Sweden, were included in the study. They were divided into the intervention group (24 units equipped with AEDs) and the standard care group (24 units with no AEDs). Intervention group staff w ere trained in CPR to use AEDs and standard care group staff w ere trained in just CPR. Data w ere gathered from patient records, AEDs and the Swedish National Registry of Cardiopulmonary Resuscitation (NRCR). Results: 126 IHCA patients were included, 47 in the standard care group, 79 in the intervention group. AEDs in the intervention group were connected to a defibrillator and it was ready to shock before arrival of MET in 83 . 5% of all cases. AEDs w ere ready to be used on average 96 seconds (14-427 s) before arrival of MET. Seven (15%) patients were defibrillated in the control group and Twenty (25%) in the intervention group. Defibrillation within three minutes occurred in 67% in the intervention group (11/17), compared with none (0/7) in the control group ( p = 0.02). Conclusion: A systematic implementation of AEDs in hospital wards decrease time to defibrillation compared to a standard MET response system. Larger studies are needed to evaluate the impact on the outcome.
- J. Herliz, “Svenska Hjärt-Lungräddningsregistret, Årsrapport, 2012,” National Register for Cardiac Arrest, Göteborg, 2012.
- L. J. Morrison, R. W. Neumar, J. L. Zimmerman, M. S. Link, L. K. Newby, P. W. McMullan Jr., T. V. Hoek, C. C. Halverson, L. Doering, M. A. Peberdy and D. P. Edelson, “American Heart Association emergency Cardiovascular Care Committee, Council on Cardiopulmonary, Critical Care, Perioperative and Resuscitation, Council on Cardiovascular and Stroke Nursing, Council on Clinical Cardiology, and Council on Peripeheral Vascular Disease,” Circulation, Vol. 127, No. 14, 2013, pp. 1538-1563. http://dx.doi.org/10.1161/CIR.0b013e31828b2770
- S. Aune, M. Eldh, J. Engdahl, S. Holmberg, J. Lindqvist, L. Svensson, E. Oddby and J. Herlitz, “Improvement in the Hospital Organization of CPR Training and Outcome after Cardiac Arrest in Sweden during a 10-Year Period,” Resuscitation, Vol. 82, No. 4, 2011, pp. 431-435. http://dx.doi.org/10.1016/j.resuscitation.2010.11.021
- J. P. Nolan, J. Soar, D. A. Zideman, D. Biarent, L. L. Bossaert, C. Deakin, R. W. Koster, J. Wyllie and B. Böttiger, “ERC Guidelines Writing Group. European Resuscitation Council Guidelines for Resuscitation 2010 Section 1. Executive Summary,” Resuscitation, Vol. 81, No. 10, 2010, pp. 1219-1276. http://dx.doi.org/10.1016/j.resuscitation.2010.08.021
- M. Fredriksson, S. Aune, A. B. Thorén and J. Herlitz, “In-Hospital Cardiac Arrest—An Utstein Style Report of Seven Years Experience from the Sahlgrenska University Hospital,” Resuscitation, Vol. 68, No. 3, 2006, pp. 351-358. http://dx.doi.org/10.1016/j.resuscitation.2005.07.011
- R. J. Smith, B. B. Hickey and J. D. Santamaria, “Automated External Defibrillators and In-Hospital Cardiac Arrest: Patient Survival and Device Performance at an Australian Teaching Hospital,” Resuscitation, Vol. 82, No. 12, 2011, pp. 1537-1542. http://dx.doi.org/10.1016/j.resuscitation.2011.06.025
- P. S. Chan, H. M. Krumholz, J. A. Spertus, P. G. Jones, P. Cram, R. A. Berg, M. A. Peberdy, V. Nadkarni, M. E. Mancini and B. K. Nallamothu, “American Heart Association National Registry of Cardiopulmonary Resuscitation (NRCPR) Investigators. Automated External Defibrillators and Survival after In-Hospital Cardiac Arrest,” JAMA, Vol. 304, No. 19, 2010, pp. 2129-2136. http://dx.doi.org/10.1001/jama.2010.1576
- P. S. Chan, H. M. Krumholz, G. Nichol and B. K. Nallamothu, “American Heart Association National Registry of Cardiopulmonary Resuscitation Investigators. Delayed Time to Defibrillation after In-Hospital Cardiac Arrest,” New England Journal of Medicine, Vol. 358, No. 1, 2008, pp. 9-17. http://dx.doi.org/10.1056/NEJMoa0706467