Research ArticleOpen AccessGoogle Scholar indexed
Un-Retrieved Deformed Biodegradable Polymer Coated Drug Eluting Stent after Percutaneous Coronary Intervention to Complete Occluded Right Coronary Artery: Patient at 8 Months Angiographic Follow-Up
Department of Medicine/Cardiovascular Unit, King Abdulaziz University, Jeddah, KSA
- 1 Department of Medicine/Cardiovascular Unit, King Abdulaziz University, Jeddah, KSA
International Journal of Clinical Medicine·Volume 05 (2014)·Pages 234–241·Published 14 March 2014·DOI10.4236/ijcm.2014.55037
Copy link · social · email
Abstract
Balloon rupture during stent deployment is rare, and can cause stent damage upon its retrieval. We described a case of inadequate drug-eluting stent expansion in a fibrotic and calcified mid right coronary artery lesion despite pre-treatment with high pressure balloon inflation, with rupture and entrapment of the balloon within the stent. Attempts of retrieval of the ruptured balloon caused severe deformity of the distal segment of the stent. The stent could not be crushed or retrieved, and was left in situ. Angiographic follow-up at 8 months time showed widely patent vessel.
KeywordsStent EntrapmentBalloon RuptureDeformed Stent
- Simpfendorfer, C.C., Dimas, A.P., Zaidi, A., Hollman, J., Franco, I., Knezinek, V. and Hobbs, R.E. (1986) Balloon Rupture during Coronary Angioplasty. Angiology, 37, 828-831. http://dx.doi.org/10.1177/000331978603701106
- Kwan, T., Huber, M.S., Jani, H. and Feit, A. (1994) Multiple Balloon Rupture during Coronary Angioplasty. A Case Report. Angiology, 45, 891-896. http://dx.doi.org/10.1177/000331979404501009
- Colombo and Skinner, J.M. (1990) Balloon Entrapment in a Coronary Artery: Potential Serious Complications of Balloon Rupture. Catheterization and Cardiovascular Diagnosis, 19, 23-25. http://dx.doi.org/10.1002/ccd.1810190107
- Holmes, Jr., D.R., Holubkov, R., Vlietstra, R.E., Kelsey, S.F., Reeder, G.S., Dorros, G., Williams, D.O., Cowley, M.J., Faxon, D.P., Kent, K.M., et al. (1988) Comparison of Complications during Percutaneous Transluminal Coronary Angioplasty from 1977 to 1981 and from 1985 to 1986: The National Heart, Lung, and Blood Institute Percutaneous Transluminal Coronary Angioplasty Registry. Journal of the American College of Cardiology, 12, 1149-1155. http://dx.doi.org/10.1016/0735-1097(88)92593-4
- Steffenino, G., Meier, B., Finci, L., Velebit, V., Von Segesser, L., Faidutti, B. and Rutishauser, W. (1988) Acute Complications of Elective Coronary Angioplasty: A Review of 500 Consecutive Procedures. British Heart Journal, 59, 151-158. http://dx.doi.org/10.1136/hrt.59.2.151
- Li, S.S.L. and Cheng, C.W. (2004) Coronary Angioplasty on an Impassable Calcified Stenosis Using a Buddy Balloon Technique. Catheterization and Cardiovascular Interventions, 62, 35-37. http://dx.doi.org/10.1002/ccd.20005
- Brogan III, W.C., Popma, J.J., Pichard, A.D., Satler, L.F., Kent, K.M., Mintz, G.S. and Leon, M.B. (1993) Rotational Coronary Atherectomy after Unsuccessful Coronary Balloon Angioplasty. American Journal of Cardiology, 71, 794-798. http://dx.doi.org/10.1016/0002-9149(93)90826-X
- Asakura, Y., Furukawa, Y., Ishikawa, S., Asakura, K., Sueyoshi, K., Sakamoto, M., Takagi, S., Takatsuki, S., Oyamada, K. and Okabe, T. (1998) Successful Predilation of a Resistant, Heavily Calcified Lesion with Cutting Balloon for Coronary Stenting: A Case Report. Catheterization and Cardiovascular Diagnosis, 44, 420-422. http://dx.doi.org/10.1002/(SICI)1097-0304(199808)44:4 3.0.CO;2-M
- Ahmed, W.H., Al-Anazi, M.M. and Bittl, J.A. (1996) Excimer Laser-Facilitated Angioplasty for Undilatable Coronary Narrowings. American Journal of Cardiology, 78, 1045-1047. http://dx.doi.org/10.1016/S0002-9149(96)00533-4