An Attempt on Methemoglobinemia: It’s Treatment and Relationship between Treatment and Cerebral Oximeter Value: Case Presentation
- 1 Department of Anesthesiology, University of Duzce, Faculty of Medicine, Duzce, Turkey
- 2 Department of Anesthesiology, University of Duzce, Faculty of Medicine, Duzce, Turkey
- 3 Department of Anesthesiology, University of Duzce, Faculty of Medicine, Duzce, Turkey
- 4 Department of Anesthesiology, University of Duzce, Faculty of Medicine, Duzce, Turkey
- 5 Department of Anesthesiology, University of Duzce, Faculty of Medicine, Duzce, Turkey
Abstract
Background: Our paper aimed to investigate whether there was a correlation among the pulse oximetry, cerebral oximetry (CO) and MetHb (methemoglobin) values of a patient with congenital methemoglobinemia who underwent a laparoscopic cholecystectomy operation. Case: The 35-year-old male patient with a weight of 70 kg, body massindex (BMI) of 21, American Society of Anesthesia status-2(ASA-2) category who was planned for laparoscopic cholecystectomy operation was identified to have been diagnosed with congenital methemoglobinemia as per his medical history was methemoglobin levels ranged between 12% and 20% according to the periodical measurements taken for the past 3 years. The patient received standard monitoring during anesthesia and device monitoring with a cerebral oximeter (Invos 5100C somatic/cerebral oximeter, Covidien) and a CO-oximetry (Rad ?87 “Rainbow”, Masimo Inc., Irvine, CA) device to continuously follow up his MetHb values was also added. During the intra-operative follow-up, the patient’s methemoglobin level rose to 16%, his peripheral oxygen saturation levels decreased to 86% and his cerebral oximetry values were identified to have also decreased; therefore, methylene blue (MB) was intravenously administered to the patient. The patient continued to be followed up in the post-operative period and he did not develop any complications. Discussion: Appropriate treatment and monitoring enabled the prevention of potential complications. We believe that monitoring with NIRS and MASIMO CO-oximetry device will enable physicians to perform a safe follow-up and treatment in the intraoperative and postoperative follow-up of methemoglobinemia patients.
- Barungi, N.N. and Mworozi, E. (2012) Sudden Onset Methaemoglobinaemia in a previously Well Ugandan Child: A Case Report and Litareture Review. Pan African Medical Journal, 11,49.
- Abu Laban, R.B., Zed, P.J. and Purssell, R.A. (2001) Severe Methemoglobinemia from Topical Anesthetic Spray: Case Report, Discussion End Qualitative Systematic Review. CJEM, 3,51-56.
- Cortazzo, J.A. and Lichtman, A.D. (2014) Methemoglobinemia: A Review and Recommendations for Management. Journal of Cardiothoracic and Vascular Anesthesia, 28, 1055-1059. http://dx.doi.org/10.1053/j.jvca.2013.02.005
- Groeper, K., Katcher, K. and Tobias, J.D. (2003) Anesthetic Management of a Patient with Methemoglobinemia. Southern Medical Journal, 96, 504-509. http://dx.doi.org/10.1097/01.SMJ.0000051342.99317.99
- Chui, J.S., Poon, W.T., Chan, K.C., et al. (2005) Nitrite-Induced Methaemoglobinemia Aetiology, Diagnosis and Treatment. Anesthesia, 60, 496-500. http://dx.doi.org/10.1111/j.1365-2044.2004.04076.x
- do Nascimento, T.S., Pereira, R.O., de Mello, H.L., et al. (2008) Methemoglobinemia: From Diagnosis to Treatment. Revista Brasileira de Anestesiologia, 58, 651-664.
- Danel, V., et al. (1995) Methemoglobinemia. Cardiff 3/95, Berlin 10/95.
- Modarai, B., Kapadia, Y.K., Kerins, M., et al. (2002) Blue: A Treatment for Severe Methemoglobinemia Secondary to Misuse of Amylnitrite. Emergency Medicine Journal, 19,270-271. http://dx.doi.org/10.1136/emj.19.3.270
- Pretto, J.J., Roebuck, T., Beckert, L., et al. (2014) Clinicaluse of Pulse Oxmetry: Official Guidelines from the Thoracic Society of Austaliaand New Zealand. Respirology, 19, 38-46. http://dx.doi.org/10.1111/resp.12204
- Barker, S.J., Curry, J., Redford, D., et al. (2006) Measurement of Carboxyhemoglobin and Methemoglobin by Pulse Oximetry. Anesthesiology, 105, 892-897. http://dx.doi.org/10.1097/00000542-200611000-00008
- Health Devices (1995) Blood Gas/pH Analysers. Health Devices, 24, 498-501.
- Else, W. (1972) Measuring Gas in Blood. Nature, 239, 47.
- Keilin, D. (1925) On Cytochrome, a Respiratory Pigment Common to Animals, Yeast, and Higher Plants. Proceedings of the Royal Society, Series B, Biological Sciences, 98, 312.
- Jobsis, F.F. (1977) Noninvasive, Infrared Monitoring of Cerebral and Myocardial Oxygen Sufficiency and Circulatory Parameters. Science, 198, 1264-1267. http://dx.doi.org/10.1126/science.929199