A Fluorescence Ratiometric Probe for Cysteine/Homocysteine and Its Application for Living Cell Imaging
- 1 Functional Molecular Materials Research Centre, Scientific Research Academy & School of Chemistry and Chemical Engineering, Jiangsu University, Zhenjiang, China
- 2 Functional Molecular Materials Research Centre, Scientific Research Academy & School of Chemistry and Chemical Engineering, Jiangsu University, Zhenjiang, China
- 3 Functional Molecular Materials Research Centre, Scientific Research Academy & School of Chemistry and Chemical Engineering, Jiangsu University, Zhenjiang, China
Abstract
A fluorescence ratiometric probe 1 for cysteine (Cys) and homocysteine (Hcy) has been rationally constructed based on intramolecular charge transfer (ICT) mechanism. Upon treatment with Cys/Hcy, probe 1 exhibited a fluorescence ratiometric response, with the emission wavelength displaying a large shift (from 526 nm to 446 nm). When 90 μM Cys were added, the emission ratios (I 446 /I 526 ) of the probe changed dramatically from 0.01797 to 4.65472. The detection limit was also measured to be 0.18 μM ( S / N = 3). The theoretical calculations have confirmed that the ratiometric response of probe 1 to Cys/Hcy is due to the inhibition of ICT process upon the reaction of probe 1 with Cys/Hcy. Furthermore, the fluorescence imaging experiments in living cell demonstrated that probe 1 was favourable for intracellular Cys/Hcy imaging.
- Z. A. Wood, E. Schroder, J. R. Harris and L. B. Poole, “Structure, Mechanism and Regulation of Peroxiredoxins,” Trends in Biochemical Sciences, Vol. 28, No. 1, 2003, pp. 32-40. http://dx.doi.org/10.1016/S0968-0004(02)00003-8
- S. Shahrokhian, “Lead Phthalocyanine as a Selective Carrier for Preparation of a Cysteine-Selective Electrode,” Analytical Chemistry, Vol. 73, No. 24, 2001, pp. 5972-5978. http://dx.doi.org/10.1021/ac010541m
- S. Seshadri, A. Beiser, J. Selhub, P. F. Jacques, I. H. Rosenberg, R. B. D’Agostino, P. W. F. Wilson and P. A. Wolf, “Plasma Homocysteine as a Risk Factor for Dementia and Alzheimer’s Disease,” The New England Journal of Medicine, Vol. 346, No. 7, 2002, pp. 476-483. http://dx.doi.org/10.1056/NEJMoa011613
- X. Chen, T. Pradhan, F. Wang, J. S. Kim and J. Yoon, “Fluorescent Chemosensors Based on Spiroring-Opening of Xanthenes and Related Derivatives,” Chemical Reviews, Vol. 112, No. 3, 2012, pp. 1910-1956. http://dx.doi.org/10.1021/cr200201z
- H. S. Jung, X. Chen, J. S. Kim and J. Yoon, “Recent Progress in Luminescent and Colorimetric Chemosensors for Detection of Thiols,” Chemical Society Reviews, Vol. 42, No. 14, 2013, pp. 6019-6031. http://dx.doi.org/10.1039/c3cs60024f
- D. Srikun, E. W. Miller, D. W. Domaille and C. J. Chang, “An ICT-Based Approach to Ratiometric Fluorescence Imaging of Hydrogen Peroxide Produced in Living Cells,” Journal of the American Chemical Society, Vol. 130, No. 14, 2008, pp. 4596-4597. http://dx.doi.org/10.1021/ja711480f
- K. Kikuchi, H. Takakusa and T. Nagano, “Recent Advances in the Design of Small Molecule-Based FRET Sensors for Cell Biology,” TrAC, Trends in Analytical Chemistry, Vol. 23, No. 6, 2004, pp. 407-415. http://dx.doi.org/10.1016/S0165-9936(04)00608-9
- C. S. Lim, G. Masanta, H. J. Kim, J. H. Han, H. M. Kim and B. R. Cho, “Ratiometric Detection of Mitochondrial Thiols with a Two-Photon Fluorescent Probe,” Journal of the American Chemical Society, Vol. 133, No. 29, 2011, pp. 11132-11135. http://dx.doi.org/10.1021/ja205081s
- G. Kim, K. Lee, H. Kwon and H. Kim, “Ratiometric Fluorescence Imaging of Cellular Glutathione,” Organic Letters, Vol. 13, No. 11, 2011, pp. 2799-2801. http://dx.doi.org/10.1021/ol200967w
- S. Lim and H. Kim, “Ratiometric Detection of Cysteine by a Ferrocenyl Michael Acceptor,” Tetrahedron Letters, Vol. 52, No. 25, 2011, pp. 3189-3190. http://dx.doi.org/10.1016/j.tetlet.2011.03.153
- L. Niu, Y. Guan, Y. Chen, L. Wu, C. Tung and Q. Yang, “BODIPY-Based Ratiometric Fluorescent Sensor for Highly Selective Detection of Glutathione Over Cysteine and Homocysteine,” Journal of the American Chemical Society, Vol. 134, No. 46, 2012, pp. 18928-18931. http://dx.doi.org/10.1021/ja309079f