Modelling the inhalation of drug aerosols in a human nasal cavity
- 1
- 2
- 3
Abstract
A human nasal cavity was reconstructed from CT scans to make a Computational Fluid Dynamics (CFD) model. With this model, fluid flow and inhalation of aerosol analysis can be investigated. The surface of the interior nasal cavity is lined with highly vascularised mucosa which provides a means for direct drug delivery into the blood stream. Typical sprayed particles from a nasal spray device produce a particle size distribution with a mean diameter of 50μm, which leads to early deposition due to inertial impaction. In this study low-density drug particles and submicron particles (including nanoparticles) are used to evaluate their deposition patterns. It was found that the low-density particles lightens the particle inertial properties however the particle inertia is more sensitive to the particle size rather than the density. Moreover the deposition pattern for nano- particles is spread out through the airway. Thus an opportunity may exist to develop low-density and nanoparticles to improve the efficiency of drug delivery to target deposition on the highly vascularised mucosal walls.
- Kimbell, J., Shroeter, J.D., Asgharian, B., Wong, B.A., Segal, R.A., Dickens, C.J., Southall, J.P. and Millerk F. J. (2004) Optimisation of nasal delivery devices using computational models. Res. Drug Del., 9 233-238.
- Inthavong, K., Tian, Z.F., Tu, J.Y., Yang, W. and Xue, C. (2008) Optimising nasal spray parameters for efficient drug delivery using computational fluid dynamics. Computers in Biology and Medicine, 38(6), 713-726.
- Inthavong, K., Tian, Z.F., Li, H. F., Tu, J.Y., Yang, W., Xue, C.L. and Li, C.G. (2006) A numerical study of spray particle deposition in a human nasal cavity. Aerosol Science Technology, 40, 1034-1045.
- Cheng, Y.S., Holmes, T.D., Gao, J., Guilmette, R.A., Li, S., Surakitbanharn, Y. and Rowlings, C. (2001) Characterization of nasal spray pumps and deposition pattern in a replica of the human nasal airway. J. Aerosol Medicine, 14 (2), 267-280.
- Edwards, D.A., Hanes, J., Caponetti, G., Hrkach, J., Ben-Jebria, A., Eskew, M.L., Mintzes, J., Deaver, D., Lotan, N. and Langer, R. (1997) Large porous particles for pulmonary drug delivery. Science, 276, 1868-1872.
- Gupta, A.K. and Gupta, M. (2005) Synthesis and surface engineering of iron oxide nanoparticles forbiomedical applications. Biomaterials, 25(18), 3995.
- McCarthy, J.R., Kelly, K.A., Sun, E.Y. and Weissleder, R. (2007) Targeted delivery of multifunctional magnetic nanoparticles. Nanomedicine, 2(2), 153-167.
- Keyhani, K., Scherer, P.W. and Mozell, M.M. (1995) Numerical simulation of airflow in the human nasal cavity. J. Biomechanical Engineering, 117, 429-441.
- Subramaniam, R.P., Richardson, R.B., Morgan, K.T., Kimbell, J.S. and Guilmette, R.A. (1998) Computational fluid dynamics simulations of inspiratory airflow in the human nose and nasopharynx. Inhalation Toxicology, 10, 91-120.
- Finckl M.H. and Wlokas, D.I. (2006) Simulation of nasal flow by lattice Boltzmann methods. Computers Biology Medicine, 37(6), 739-749.
- Hahn, I., Scherer, P.W. and Mozell, M.M. (1993) Velocity profiles measured for airflow through a large- scale model of the human nasal cavity. J Appl. Physiol., 75(5), 2273-2287.
- Zamankhan, P., Ahmadi, G., Wang, Z., Hopke, P.H., Cheng,Y.S., Su, W.C. and Leonard, D. (2006) Airflow and deposition of nanoparticles in a human nasal cavity. Aerosol Science Technol., 40, 463-476.
- Mumford, D. and Shah, J. (1989) Optimal approximations by piecewise smooth functions and associated variational problems. Commincations Pure and Applied Mathematics, XLII, 577-685.