Stresses in the Scapular Fossa Do Not Exceed the Yield Stress When Elevated up to 135 Degrees of Abduction after Reverse Shoulder Arthroplasty
- 1 Department of Medical Engineering and Technology, Kitasato University School of Allied Health Sciences, Sagamihara, Japan
- 2 Department of Orthopedic Surgery, Kitasato University School of Medicine, Sagamihara, Japan
- 3 Department of Orthopedic Surgery, Kitasato University School of Medicine, Sagamihara, Japan
- 4 Department of Medical Engineering and Technology, Kitasato University School of Allied Health Sciences, Sagamihara, Japan
- 5 Kitasato University Graduate School of Medical Sciences, Sagamihara, Japan
- 6 Department of Medical Engineering and Technology, Kitasato University School of Allied Health Sciences, Sagamihara, Japan
Abstract
Reverse shoulder arthroplasty (RSA) is an effective treatment for rotator cuff tears. Despite its advantages, complications occur at a high rate. Complications requiring revision include a high rate of base plate failure, 38% of which are due to instability. The primary stability the base plate ensures is a crucial factor and, thus, is the subject of much debate in clinical studies and biomechanical research. This study is aimed to provide data that will contribute to the base plate’s pri-mary stability and glenoid longevity by clarifying the stresses at the scapular fossa and base plate interface associated with elevation after RSA. A 3D finite element model was created from the DICOM data for the scapulohumeral joint and SMR shoulder system. For loading conditions, 30 N was applied for each posi-tion with abduction angles of 0, 45, 90, and 135 degrees. A three-dimensional fi-nite element analysis was performed using the static implicit method with LS-DYNA. The von Mises stresses in the scapular fossa were found not to exceed the yield stress on the bone even after elevation to an abduction angle of 135 de-grees after RSA. It is rough to uniformly compare the yield stress and the von Mises stress, but it was inferred that the possibility of fracture is low unless a large external force is applied. A maximum von Mises stress showed 0 degrees of abduction, suggesting that the lowered position is in a more severe condition than the elevated position. If better improvement is desired, it may be necessary to devise ways to reduce the stress on the upper screw.
- Cuff, D., Clark, R., Pupello, D., et al. (2012) Reverse Shoulder Arthroplasty for the Treatment of Rotator Cuff Deficiency: A Concise Follow-Up, at a Minimum of Five Years, of a Previous Report. The Journal of Bone and Joint Surgery, 94, 1996-2000. https://doi.org/10.2106/JBJS.K.01206
- Frankle, M., Siegal, S., Pupello, D., et al. (2005) The Reverse Shoulder Prosthesis for Glenohumeral Arthritis Associated with Severe Rotator Cuff Deficiency. A Minimum Two-Year Follow-Up Study of Sixty Patients. The Journal of Bone and Joint Surgery, 87, 1697-1705. https://doi.org/10.2106/00004623-200508000-00005
- Smith, C.D., Guyver, P. and Bunker, T.D. (2012) Indications for Reverse Shoulder Replacement: A Systematic Review. The Bone and Joint Journal, 94, 577-583. https://doi.org/10.1302/0301-620X.94B5.27596
- Boileau, P., Watkinson, D.J., Hatzidakis, A.M., et al. (2005) Grammont Reverse Prosthesis: Design, Rationale, and Biomechanics. Journal of Shoulder and Elbow Surgery, 14, 148S-161S. https://doi.org/10.1016/j.jse.2004.10.006
- Stephens, B.C., Simon, P., Clark, R.E., et al. (2016) Revision for a Failed Reverse: A 12-Year Review of a Lateralized Implant. Journal of Shoulder and Elbow Surgery, 25, 115-124. https://doi.org/10.1016/j.jse.2015.09.027
- Boileau, P., Moineau, G., Roussanne, Y., et al. (2011) Bony Increased-Offset Reversed Shoulder Arthroplasty: Minimizing Scapular Impingement While Maximizing Glenoid Fixation. Clinical Orthopaedics and Related Research, 469, 2258-2567. https://doi.org/10.1007/s11999-011-1775-4
- Henninger, H.B., Barg, A., Anderson, A.E., et al. (2012) Effect of Lateral Offset Center of Rotation in Reverse Total Shoulder Arthroplasty: A Biomechanical Study. Journal of Shoulder and Elbow Surgery, 21, 1125-1135. https://doi.org/10.1016/j.jse.2011.07.034
- Sanjay, G. and Prosenjit, D. (2004) Bone Geometry and Mechanical Properties of the Human Scapula Using Computed Tomography Data. Trends in Biomaterials and Artificial Organs, 17, 61-69.
- Huang, Y., Ernstbrunner, L., Robinson, D.L., et al. (2016) Complications of Reverse Total Shoulder Arthroplasty: A Computational Modelling Perspective. Journal of Clinical Medicine, 10, 5336. https://doi.org/10.3390/jcm10225336
- Anglin, C., Tolhurst, P., Wyss, U.P., et al. (1999) Glenoid Cancellous Bone Strength and Modulus. Journal of Biomechanics, 32, 1091-1097. https://doi.org/10.1016/S0021-9290(99)00087-1
- Denard, P., Lederman, E., Persons, B.O., et al. (2016) Finite Element Analysis of Glenoid-Sided Lateralization in Reverse Shoulder Arthroplasty. Journal of Orthopaedic Research, 35, 1548-1555. https://doi.org/10.1002/jor.23394