Research ArticleOpen AccessGoogle Scholar indexed
A charge of the erythrocyte test by automated method
Department of Biological Physics and Medical Informatics, Bukovinian State Medical University, Chernivtsi, Ukraine
Department of Biological Physics and Medical Informatics, Bukovinian State Medical University, Chernivtsi, Ukraine
Chernivtsi Regional Hospital, Chernivtsi, Ukraine
Department of Electronics and Electrotechnics, Yuriy Fedkovych Chernivtsi National University, Chernivtsi, Ukraine
- 1 Department of Biological Physics and Medical Informatics, Bukovinian State Medical University, Chernivtsi, Ukraine
- 2 Department of Biological Physics and Medical Informatics, Bukovinian State Medical University, Chernivtsi, Ukraine
- 3 Chernivtsi Regional Hospital, Chernivtsi, Ukraine
- 4 Department of Electronics and Electrotechnics, Yuriy Fedkovych Chernivtsi National University, Chernivtsi, Ukraine
Journal of Biomedical Science and Engineering·Volume 05 (2012)·Pages 186–189·Published 19 April 2012·DOI10.4236/jbise.2012.54024
Copy link · social · email
Abstract
New methods of an automated evaluation of the blood rheological parameters: 1) the viscosity, 2) electric conductivity and 3) the charge of erythrocytes have been theoretically and experimentally substantiated by way of registering the Q-factor of the tuned-circuit, containing a capillary with the blood flow. A design of an electronic measuring complex is based on modeling the physical blood conditions in the natural environment.
KeywordsBiophysicsPhysical Methods of Evaluating Blood Rheological Properties and ParametersQuality Factor (Q-Factor)Designing
- Kuz’menko, O.Yu. (2003) Rotary viscometers with the superhigh frequency system of transformation of a controlled parameter. Author’s abstract of dissert of Cand. of Med. Sci.. Tambov, TSTU. (In Russian). http://www.twirpx.com/file/510318/
- Shaplavs’kyi, M.V. (1996) Bioinertization as a biological function. Prut., Chernivtsi. (In Ukrainian).
- Fahraeus, R. and Linqvist, T. (1931) The viscosity of the blood in narrow capillary tubes. American Journal of Physiology, 96, 562-568.
- Isenberg, J. (1953) A note of the flow of blood in capillary tubes. Bulletin of Mathematical Biophysics, 15, 149-152. doi:10.1007/BF02476379
- Shaplavs’kyi, M.V., Pishak, V.P., Slobodian, O.V. and Hrygoryshyn, P.M. (2008) Patent 35766 of Ukraine. Electrode-free method for automated measurement of viscosity of biological fluids. Bulletin No. 19. (In Ukraini http://base.ukrpatent.org/searchINV/search.php?action=viewdetails&IdClaim=124456
- Gutsul, O.V., Buzhdygan, V.V., Shaplavs’kyi, M.V. and Grygoryshyn, P.M. (2010) The measuring complex for the viscosity test of the biological fluids. Buk. Med. Herald., 14, 158-164 (In Ukrainian).
- Shaplavs’kyi, M.V., Pishak, V.P., et al. (2008) Patent 36976 of Ukraine. Electrode-less method for automated measurement of specific resistance of electrolytes and biological liquids. Bulletin No. 21 (In Ukrainian). http://base.ukrpatent.org/searchINV/search.php?action=viewdetails&IdClaim=125813
- Yevdokimov, I.N. and Yelisieiev, N.Yu. (2005) Molecular mechanisms of the viscosity of a liquid and gas. Part I. Principal notions. RSU of Oil and Gas Named after I.M. Gubkin Press, Мoscow (In Russian). http://www.twirpx.com/file/439320/