Abstract
The purpose of the study was to evaluate the effect of motion compensation by non-rigid registration combined with the Karhunen-Loeve Transform (KLT) filter on the signal to noise (SNR) and contrast-to-noise ratio (CNR) of hybrid gradient-echo echoplanar (GRE-EPI) first-pass myocardial perfusion imaging. Twenty one consecutive first-pass adenosine stress perfusion MR data sets interpreted positive for ischemia or infarction were processed by non-rigid Registration followed by KLT filtering. SNR and CNR were measured in abnormal and normal myocardium in unfiltered and KLT filtered images following nonrigid registration to compensate for respiratory and other motions. Image artifacts introduced by filtering in registered and nonregistered images were evaluated by two observers. There was a statistically sig- nificant increase in both SNR and CNR between normal and abnormal myocardium with KLT filtering (mean SNR increased by 62.18% ± 21.05% and mean CNR increased by 58.84% ± 18.06%; p = 0.01). Motion correction prior to KLT filtering reduced significantly the occurrence of filter induced artifacts (KLT only-artifacts in 42 out of 55 image series vs. registered plus KLT-artifacts in 3 out of 55 image series). In conclusion the combination of non-rigid registration and KLT filtering was shown to increase the SNR and CNR of GRE-EPI perfusion images. Subjective evaluation of image artifacts revealed that prior motion compensation significantly reduced the artifacts introduced by the KLT filtering proces s.
- Gebker, R., Schwitter, J., Fleck, E. and Nagel, E. (2007) How we perform myocardial perfusion with cardiovascu- lar magnetic resonance. Journal of Cardiovascular Mag- netic Resonance, 9, 539-547. doi:10.1080/10976640600897286
- Kellman, P. and Arai, A.E. (2007) Imaging sequences for first pass perfusion: A review. Journal of Cardiovascular Magnetic Resonance, 9, 525-537. doi:10.1080/10976640601187604
- Di Bella, E.V., Wu, Y.J., Alexander, A.L., Parker, D.L., Green, D. and McGann, C.J. (2003) Comparison of tem- poral filtering methods for dynamic contrast MRI myo- cardial perfusion studies. Magnetic Resonance in Medi- cine, 49, 895-902. doi:10.1002/mrm.10439
- Goldstein, T.A., Zhang, H., Misselwitz, B., Gropler, R.G. and Zheng, J. (2006) Improvement of quantification of myoardial first-pass perfusion mapping: A temporal and spatial wavelet denoising method. Magnetic Resonance in Medicine, 56, 439-445. doi:10.1002/mrm.20950
- Bidaut, L.M. and Vallee, J.P. (2001) Automated registra- tion of dynamic MR images for the quantification of myocardial perfusion. Journal of Magnetic Resonance Imaging, 13, 648-655. doi:10.1002/jmri.1092
- Dornier, C., Ivancevic, M.K., Thevenaz, P. and Vallee, J.P. (2003) Improvement in the quantification of myocar- dial perfusion using an automatic spline-based registra- tion algorithm. Journal of Magnetic Resonance Imaging, 18, 160-168. doi:10.1002/jmri.10351
- Gallippi, C.M., Kramer, C.M., Hu, Y.L., Vido, D.A., Rei- chek, N. and Rogers, W.J. (2002) Fully automated Regis- tration and warping of contrast-enhanced first-pass perfu- sion images. Journal of Cardiovascular Magnetic Reso- nance, 4, 459-469. doi:10.1081/JCMR-120016384
- Gupta, S.N., Solaiyappan, M., Beache, G.M., Arai, A.E. and Foo, T.K. (2003) Fast method for correcting image misregistration due to organ motion in time-series MRI data. Magnetic Resonance in Medicine, 49, 506-514. doi:10.1002/mrm.10394
- Ding, Y., Chung, Y.C., Raman, S.V. and Simonetti, O.P. (2009) Application of the Karhunen-Loeve transform temporal image filter to reduce noise in real-time cardiac cine MRI. Physics in Medicine and Biology, 54, 3909- 3922. doi:10.1088/0031-9155/54/12/020
- Ding, Y., Chung, Y.-C., Raman, S. and Simonetti, O. (2008) Characteristics and performance of the Karhunen- Loeve transform filter in dynamic magnetic resonance imaging. Pro-ceedings of the 16th International Society of Magnetic Resonance in Medicine Annual Scientific Meet- ing & Exhibition, Toronto, 3-9 May 2008, 2858.