Stability of the magnetic resonance (MR) contrast agent inside vascular occlusion agents is important for their localization with magnetic resonance imaging (MRI). The aim of this paper is to study the behaviour of the superparamagnetic iron oxide (SPIO) within Hepaspheres? microparticles (MP) by MRI when they are submitted to negative pressure induced by venous drainage of a tumor. Therefore, a venous drainage model was established and three parameters were taken into account according to physiologic parameters in tumors: pH, temperature and flow blood rate. Four cycles of pumping were performed with the presence of labeled Hepaspheres? with Endorem®. Several MR images of MP and perfusion liquid were taken before and after pumping. Endorem® release was determined after correction of non-uniformity intensities in MR images. Intensity variation according to spatial position, coil and MR acquisition parameters was studied. Labeled microparticles (LB*MP) appeared as black spots in MRI images whatever duration and pH. Our model demonstrates the stability of the SPIO inside the occlusion agent during time. Moreover, the proposed correction method proves the reduction of the intensity non-uniformity in MRI images.
- Laurent, A., Wassef, M., Chapot, R., Wang, Y., Houdart, E., Feng, L., Tran Ba Huy, E. and Merland, J.J. (2005) Partition of calibrated tris-acryl gelatin microspheres in the arterial vasculature of embolized nasopharyngeal angiofibromas and paragangliomas. Journal of Vascular and Interventional Radiology, 16(4), 507-513.
- Osuga, K., Hori, S., Kitayoshi, H., Khankan, A., Okada, A., Sugiura, T., Murakami, T., Hosokawa, K. and Nakamura, H. (2002) Embolization of high flow arteriovenous malformations: Experience with use of superabsorbent polymer microspheres. Journal of Vascular and Interventional Radiology, 13(11), 1125-1133.
- De Luis, E., Bilbao, J.I., de Ciércoles, J.A.G.J., Cuesta, A. M., Rodríguez, A.M. and Lozano, M.D. (2008) In vivo evaluation of an new embolic spherical particle (HepaSphere) in a kidney animal model. Cardiovascular and Interventional Radiology, 31(2), 367-376.
- Osuga, K., Khankan, A.A., Hori, S., Okada, A., Sugiura, T., Maeda, M., Nagano, H., Yamada, A., Murakami, T. and Nakamura, H. (2002) Transarterial embolization for large hepatocellular carcinoma with the use of superabsorbent polymer microspheres: initial experience. Journal of Vascular and Interventional Radiology, 13(9), 929- 934.
- Jassar, H. (2009) Detectability of vascular occlusion materials for MRI follow-up. Ph.D. Dissertation, Compiegne University of Technology, Compiegne.
- Vaupel, P., Rallinowski, F. and Okunieff, P. (1989) Blood flow, oxygen and nutrient supply, and metabolic microenvironment of human tumors: A review. Cancer Research, 49(23), 6449-6465.
- Tancredi, T., McCuskey, P.A., Kan, Z. and Wallace, S. (1999) Changes in rat liver microcirculation after experimental hepathic arterial embolization: Comparison of different embolic agents. Radiology, 12(1), 117-181.
- Khankan, A.A., Osuga, K., Hori, S., Morii, E., Murakami, T. and Nakamura, H. (2004) Embolic effects of superabsorbent polymer microspheres in rabbit renal model: comparison with tris-acryl gelatin microspheres and polyvinyl alcohol. Radiation Medicine, 22(6), 384-390.
- Simmons, A., Arridge, S.R., Barker, G.J. and Williams, S.C. (1994) Sources of intensity nonuniformity in spin echo images at 1.5 T. Magnetic Resonance in Medicine, 32(1), 12-18.
- Haacke, E.M., Brown, R.W., Thompson, M.R. and Venkatesan, R. (1999) Magnetic resonance imaging. Physical Principles and Sequence Design, Wiley-Liss, New York.
- Wicks, D.A.G., Barker, G.J. and Tofts, P.S. (1993) Correction of intensity nonuniformity in MR images of any orientation. Magnetic Resonance Imaging, 11(2), 183- 196.