Research ArticleOpen AccessGoogle Scholar indexed
Pulsatile MHD Flow in an Inclined Catheterized Stenosed Artery with Slip on the Wall
Department of Mathematics, Guru Jambheshwar University of Science & Technology, Hisar, India
Department of Mathematics, Guru Jambheshwar University of Science & Technology, Hisar, India
Department of Mathematics, Guru Jambheshwar University of Science & Technology, Hisar, India
- 1 Department of Mathematics, Guru Jambheshwar University of Science & Technology, Hisar, India
- 2 Department of Mathematics, Guru Jambheshwar University of Science & Technology, Hisar, India
- 3 Department of Mathematics, Guru Jambheshwar University of Science & Technology, Hisar, India
Journal of Biomedical Science and Engineering·Volume 07 (2014)·Pages 194–207·Published 6 March 2014·DOI10.4236/jbise.2014.74023
Copy link · social · email
Abstract
Catheter is commonly used by the surgeons for various reasons in the treatment of a patient suffering with cardiovascular diseases. Catheterization increases the mean flow resistance in the arterial blood flow and many other complications are associated with the presence of catheter in the artery. Effects of catheter in stenosed artery can be estimated non-invasively by means of hemo-dynamic indicator-WSS, WSSG, volume flow rate and impedance. The effect of slip at the arterial wall, inclination of the artery and magnetic field on the hemodynamic indicators and flow profiles are computed, presented and discussed through graphs.
KeywordsStenosed ArteryWall Shear StressWall Shear Stress GradientImpedanceCatheter
- Fung, Y.C. (1984) Biodynamics Circulation. Springer-Verlag, New York.
- McDonald, D.A. (1960) Blood Flow in Arteries. Arnold, London.
- Mazumdar, J.N. (1992) Bio-fluid Mechanics. Word Scientific Press.
- Zamir, M. (2005) The Physics of Coronary Blood Flow. Springer, New York.
- Young, D.F. (1979) Fluid Mechanics of Arterial Stenoses. Journal of Biomechanical Engineering, 101, 157-175. http://dx.doi.org/10.1115/1.3426241
- Srivastava, V.P. (1996) Two Phase Model of Blood Flow through Stenosed Tubes in the Presence of a Peripheral Layer: Applications, Journal of Biomechanics, 29, 1377-1382. http://dx.doi.org/10.1016/0021-9290(96)00037-1
- Srivastava, V.P. (2002) Particulate Suspension Blood Flow through Stenotic Arteries: Effect of Hematocrit and Stenosis Shape. Indian Journal of Pure and Applied Mathematics, 33, 1353-1360.
- Liu, Z.-R., Xu, G., Chen, Y., Teng, Z.-Z. and Qin, K.-R. (2003) An Analysis Model of Pulsatile Blood Flow in Arteries. Applied Mathematics and Mechanics, 24, 230-240. http://dx.doi.org/10.1007/BF02437630
- Yao, L. and Li, D.-Z. (2006) Pressure and Pressure Gradient in an Axisymmetric Rigid Vessel with Stenosis. Applied Mathematics and Mechanics (English Edition), 27, 347-351. http://dx.doi.org/10.1007/s10483-006-0310-z
- Mekheimer, Kh.S. and El Kot, M.A. (2008) Influence of Magnetic Field and Hall Currents on Blood Flow through a Stenotic Artery. Applied Mathematics and Mechanics (English Edition), 29, 1093-1104.
- Kanai, H., Lizuka, M. and Sakamotos, K. (1996) One of the Problem in the Measurement of Blood Pressure by Catheterization: Wave Reflection at the Tip of Catheter. Medical & Biological Engineering, 28, 483-496.
- Back, L.H., Kwack, E.Y. and Back, M.R. (1996) Flow Rate-Pressure Drop Relation in Coronary Angioplasty: Catheter Obstruction Effect. Journal of Biomechanical Engineering, 118, 83-89.
- Jones, A.L. (1966) On the Flow of Blood in a Tube. Biorheology, 3, 183-188.
- Nubar, Y. (1967) Effects of Slip on the Rheology of a Composite Fluid: Application to Blood Flow. Rheology, 4, 133-150.
- Brunn, P. (1975) The Velocity Slip of Polar Fluids. Rheologica Acta, 14, 1039-1054. http://dx.doi.org/10.1007/BF01515899
- Bugliarello, G. and Sevilla, J. (1970) Velocity Distribution and Other Characteristics of Steady and Pulsatile Blood Flow in Fine Glass Tubes. Biorheology, 7, 85-107.