Noninvasive method for determining blood pressure and contours of arterial and volume pulses
- 1 Department of Physics, Norwegian University of Science and Technology
- 2 Department of Physics, Norwegian University of Science and Technology
- 3 The Aga Khan University
- 4 The Aga Khan University
Abstract
A noninvasive method for monitoring blood pressure, based on the principles established by Riva-Rocci and Korotkoff (K), is described; it furnishes, after a single compression-deflation cycle of the arm-encircling cuff, values of sys-tolic and diastolic blood pressures as well as the contours of the brachial arterial pulse and the corresponding volume pulse. K-sounds are detected by a single microphone situated in the cubital fossa, and the time-varying cuff pressure P(t) is read by a piezoresistive pressure sensor. The behavior of P(t) during deflation is resolved into two parts, P(t)=p(t)+b(t); p is a train of posi-tive going pulses (arising from arterial pulsa-tions), whereas b is a slowly changing baseline. Noise pulses in the microphone output are re-jected by using the observation that the first few K-sounds are emitted when p is close to a maxi-mum, and the last few when dp/dt is close to a maximum. The performance of the instrument is illustrated by showing how it copes with ambi-ent noise and involuntary manual perturbations of P, and by presenting contours of various pulses.
- Gilford, S.R. Automatic sphygmomanometer. U.S. Patent 2,827,040, March 18, 1958.
- Geddes, L.A., Spencer, W.A. and Hoff, H.E. (1959) Graphic recording of the Korotkoff sounds. Am. Heart J. 57, 361–370.
- Geddes, L.A. and Moore, A.G. (1968) The efficient detection of Korotkoff sounds. Med Biol. Eng. Comput. 6, 603儃609.
- Edwards, W.C. Apparatus for measuring blood pressure. U.S.Patent 3,405,707, October 15, 1968.
- Hurwitz, M. Automatic recording sphygmomanometer. U.S. Patent 3,771,515, November 13, 1973.
- Aisenberg, S. and Chabot, R.W. Noise rejecting electronic sphygmomanometer and methods for measuring blood pressure. US Patent 4,005,701, February 1, 1977.
- Trimmer, G.A. and Slechta, E.W. Mthod and apparatus for measurement of blood pressure and pulse rate. US Patent 4,245,648, January 20, 1981.
- Swearingen, J.D. and Watson, R.C. Methods of and apparatus for the measurement of blood pressure. US Patent 4263918, April 28, 1981.
- Geddes, L.A, Voelz. M, Combs, C., Reiner. D. and Babbs, C.F. (1982) Characterization of the oscillometric method for measuring indirect blood pressure. Ann. Biomed. Eng. 10, 271儃280.
- Ramsey, M. Automatic mean blood pressure reading device. U.S. Patent 4,360,029, November 23, 1982.
- Nunn, D.E. and Beveridge, R.W. Apparatus and method for measuring blood pressure. U.S. Patent 4,427,013, January 24, 1984.
- Miyawaki, Y., Matumoto, K. and Shirasaki, O. Electronic blood pressure meter incorporating compensation function for systolic and diastolic blood pressure determinations. US Patent 4,860,760, August 29, 1989
- Chio, S. Method and apparatus for determining blood pressure and cardiovascular condition. U.S. Patent 4,880,013, November 14, 1989.
- Hata, H. and Souma, T. Automatic sphygmomanometer. US Patent 5,099,851, March 31, 1992.
- Shinomiya, T. Electronic sphygmomanometer. U.S. Patent 5,103,830, April 14, 1992.
- Brinton, T.J., Cotter, B., Kailasam, M.T., Brown, D.L., Chio, S., O’Connor, D.T. and DeMaria, A.N. (1997) Development and validation of a noninvasive method to determine arterial pressure and vascular compliance. Am. J. Cardiol. 80, 323–330.
- Pinto, L., Dhanantwari, A., Wong, W., Stergiopoulos, S. and Maris, M. (2002) Blood pressure measurement in noise intensive environment using adaptive interference cancellation. Ann. Biomed Eng. 30, 657–670.