Pattern of respiratory-induced changes in fingertip blood volume measured by light transmission
- 1
- 2
- 3
- 4
- 5
Abstract
Respiratory-induced fluctuations in heart rate and arterial blood pressure have been intensively investigated, but there is little information on the effect of respiration on peripheral blood volume. In the current study, blood volume changes in the finger, obtained by light transmission measurements, were measured during regular breathing (6 s periods) and long breathing (12 s periods). Respiratory chest-circumference changes were simultaneously measured in order to associate the pattern of tissue blood volume change with the respiratory cycle. Sixteen subjects were studied, and in fourteen finger blood vol ume increased during inspiration and decreased during expiration in the long-breathing periods. In all 14 subjects the start of blood volume decrease was significantly delayed from the start of expiration by mean ± SD 1.00 ± 0.65 s (p < 0.001, range 0 - 2.3 s). The start of blood volume increase was significantly delayed from the end of expiration by 3.45 ± 1.76 s (p < 0.005). In eight, finger blood volume started to increase more than 2 s before the start of inspiration. For the 6 s breathing period, blood volume decreased during inspiration in five examinations, and increased in seven. The increase in peripheral blood volume during inspiration could be attributed to the higher abdominal pressure during inspiration, and to the decrease in sympathetic activity during inspiration and the subsequent vasodilatation. The decrease in peripheral blood volume during inspiration is probably due to the negative thoracic pressure during inspiration and its mechanical effect on thoracic vessels.
- Gilad, O., Swenne, C.A., Davrath, L.R. and Akselrod, S. (2005) Phase-averaged characterization of respiratory sinus arrhythmia pattern. Am. J. Physiol. Heart Circ. Physiol. 288, H504-H510.
- Kotani, K., Takamasu, K., Jimbo, Y. and Yamamoto, Y. (2008) Postural induced phase shift of respiratory sinus arrhythmia and blood pressure variations: insight from respiratory-phase domain analysis. Am. J. Physiol. Heart Circ. Physiol. 294, H1481-H1489.
- Sin, P.Y.W., Galletly, D.C. and Tzeng, Y.C. (2010) Influence of breathing frequency on the pattern of respiratory sinus arrhythmia and blood pressure; old questions revisited. Am J. Physiol. 298, H1588-H1599.
- Cohen, M.A. and Tailor, J.A. (2002) Short-term cardiovascular oscillations in man: measuring and modeling the physiologies. J. Physiol. 542.3, 669-683.
- Izzo, J.L. (1990) Labile hypertension, vasomotor instability and postural syndromes in J.H. Laragh and B.M. Brenner, Editors, Hypertension: Pathophysiology, diagnosis and Management. Raven Press, New York, 1415-1427.
- Muzi, M. and Ebert T. J. (1993) Quantification of heart rate variability with power spectral analysis. Curr. Opinion Anaest. 6, 3-17.
- Triedman, J. K. and Saul, J. P. (1994) Blood pressure modulation by central venous pressure and respiration. Buffering effects of the heart rate reflexes. Circulation, 89, 169-179.
- Mulinos M.G. and Shulman, (1938) I.Vasoconstriction in the hand from a deep inspiration. Am. J, Physiol. 125, 310-322,
- Allen, J., Frame, J.R. and Murray, A. (2002) Microvascular blood flow and skin temperature changes in the fingers following a deep inspiratory gasp. Physiol. Meas. 23, 365-373.
- Wallin, B.G., Batelsson, K., Kienbaum, P. et al. (1998) Two neural mechanisms for respiration induced cutaneous vasodilatation in humans? J. Physiol. 513.2, 559-569.
- Rauh, R., Posfay, A. and Muck-Weynmann, M. (2003) Quantification of inspiratory-induced vasoconstrictive episodes: a comparison of laser Doppler fluxmetry and photoplethysmography" Clin. Physiol. Funct. Imaging 23, 344-348.
- Mayrovitz, H.N. and Groseclose, E.E. (2005) Inspiration-induced vasoconstrictive responses in dominant versus non-dominant hand. Clin. Physiol. Funct. Imaging, 25:69-77.
- Nitzan, M. de Boer, H. Turivnenko S. et al. (1994) Power spectrum analysis of the spontaneous fluctuations in the photoplethysmographic signal. J. Basic Clin. Physiol. Pharmacol. 5, 269-276.