Biomechanical Study of the Effects of Balloon Kyphoplasty on the Adjacent Vertebrae
- 1 Division of Spine Surgery, Department of Orthopedic Surgery, School of Medicine, Juntendo University, Tokyo, Japan
- 2 Division of Spine Surgery, Department of Orthopedic Surgery, School of Medicine, Juntendo University, Tokyo, Japan
- 3 Research Institute for Applied Mechanics, Kyushu University, Kasuga-City, Japan
- 4 Interdisciplinary Graduate School of Engineering Sciences, Kyushu University, Kasuga-City, Japan
- 5 Division of Spine Surgery, Department of Orthopedic Surgery, School of Medicine, Juntendo University, Tokyo, Japan
- 6 Division of Spine Surgery, Department of Orthopedic Surgery, School of Medicine, Juntendo University, Tokyo, Japan
- 7 Faculty of Electrical and Electronic Engineering, Universiti Tun Hussein Onn Malaysia, Parit Raja, Malaysia
Abstract
We used the finite element method (FEM) to investigate the stress profiles of vertebrae in patients who underwent balloon kyphoplasty (BKP) for vertebral fracture. BKP is often performed for persistent pain after vertebral fractures. However, fractures are frequently reported in the adjacent vertebrae after BKP. The purpose was to clarify the mechanism of fractures that occur in the adjacent vertebrae after BKP. The subjects were two patients (first case: 74-year-old woman; second case: 88-year-old woman) who had BKP for osteoporotic vertebral fractures (L1). A bone analysis software program, Mechanical Finder, was used to construct three-dimensional finite element models (T11-L3) from computed tomographic (CT) digital imaging and communications in medicine (DICOM) data. Moment loadings were examined to evaluate stress concentrations on the vertebrae. Young’s moduli were lower in the second case than in the first case at all vertebral levels. Maximum Drucker-Prager stresses after BKP were larger in the second case than in the first case for compression, flexion, extension, and axial rotation. Strain energy density decreased in L1 and increased in the adjacent ver-tebrae. Our results suggest that post-BKP fractures of the adjacent vertebrae not only are due to bone fragility, but also can be caused by increased rigidity in the vertebrae filled with bone cement, which increases stress concentration on the adjacent verte-brae and raises the likelihood of fracture.
- Tawara, D., Sakamoto, J., Murakami, H., Kawahara, N., Oda, J. and Tomita, K. (2010) Mechanical Evaluation by Patient-Specific Finite Element Analysis Demonstrates Therapeutic Effects for Osteoporotic Vertebrae. Journal of the Mechanical Behavior of Biomedical Materials, 3, 31-40. http://dx.doi.org/10.1016/j.jmbbm.2009.03.001
- Keyak, J.H., Rossia, S.A., Jones, K.A. and Skinner, H.B. (1998) Prediction of Femoral Fracture Load Using Automated Finite Element Modeling. Journal of Biomechanics, 31, 125-133. http://dx.doi.org/10.1016/S0021-9290(97)00123-1
- Reilly, D.T. and Burstein, A.H. (1975) The Elastic and Ultimate Properties of Compact Bone Tissue. Journal of Biomechanics, 8, 393-405. http://dx.doi.org/10.1016/0021-9290(75)90075-5
- Kurtz, S.M., Villarragaa, M.L., Zhao, K. and Edidin, A.A. (2005) Static and Fatigue Mechanical Behavior of Bone Cement with Elevated Barium Sulfate Content for Treatment of Vertebral Compression Fractures. Biomaterials, 17, 3699-3712. http://dx.doi.org/10.1016/j.biomaterials.2004.09.055
- Han, K.S., Rohlmann, A., Zander, T. and Taylor, W.R. (2013) Lumbar Spinal Loads Vary with Body Height and Weight. Medical Engineering and Physics, 35, 969-977. http://dx.doi.org/10.1016/j.medengphy.2012.09.009
- Zhang, L., Yang, G., Wu, L. and Yu, B. (2010) The Biomechanical Effects of Osteoporosis Vertebral Augmentation with Cancellous Bone Granules or Bone Cement on Treated and Non-Treated Vertebral Bodies: A Finite Element Evaluation. Clinical Biomechanics, 25, 166-172. http://dx.doi.org/10.1016/j.clinbiomech.2009.10.006
- Brekelmans, W.A., Poort, H.W. and Slooff, T.J. (1972) A New Method to Analyze the Mechanical Behavior of Skeletal Parts. Acta Orthopaedica Scandinavica, 43, 301-317. http://dx.doi.org/10.3109/17453677208998949
- Bauer, J.S., Sidorenko, I., Mueller, D., Baum, T., Issever, A.S., Eckstein, F., Rummeny, E.J., Link, T.M. and Reath, C.W. (2014) Prediction of Bone Strength by CT and MDCT-Based Finite-Element-Models: How Much Spatial Resolution Is Needed. European Journal of Radiology, 83, e36-e42. http://dx.doi.org/10.1016/j.ejrad.2013.10.024
- Julienne, E.B., Floor, M.L., Van Rietbergen, B., Ito, K. and Huiskes, R. (2009) Comparison of Bone Loss Induced by Ovariectomy and Neurectomy in Rats Analyzed by In Vivo Micro-CT. Journal of Orthopaedic Research, 27, 1521-1527. http://dx.doi.org/10.1002/jor.20913
- Mazlan, M.H., Todo, M., Takano, H. and Yonezawa, I. (2014) Finite Element Analysis of Osteoporotic Vertebrae with First Lumbar (L1) Vertebral Compression Fracture. International Journal of Applied Physics and Mathematics, 4, 267-274. http://dx.doi.org/10.7763/IJAPM.2014.V4.297