Dark Current Compensation and Sensitivity Adjustment on Gallium Arsenide Linear Array Detector for X-Ray Imaging
- 1 Department of Experimental Physics, Institute for High Energy Physics (IHEP), National Research Center “Kurchatov Institute”, Protvino, Russia
Abstract
For the last several years, the linear array x-ray detector for x-ray imaging with gallium arsenide direct conversion sensitive elements has been developed and tested at the In-stitute for High Energy Physics. The array consists of 16 sensitive modules. Each module has 128 gallium arsenide (GaAs) sensitive elements with 200 μm pitch. Current article describes two key program procedures of initial dark current compensation of each sensitive element in the linear array, and sensitivity adjustment for alignment of strip pattern in the raw image data. As a part of evaluation process a modular transfer function (MTF) was measured with the slanted sharp-edge object under RQA5 technique as it described in the International Electrotechnical Commission 62220-1 standard (high voltage 70 kVp, additional aluminium filter 21 mm) for images with compensated dark currents and adjusted sensitivity of detector elements. The 10% level of the calculated MTF function has spatial resolution within 2 - 3 pair of lines per mm for both vertical and horizontal orientation.
- Ardashev, E.N., Gorokhov, S.A., Polkovnikov, M.K., Lobanov, I.S. and Vorobiev, A.P. (2011) A Portable X-Ray Apparatus with GaAs Linear Array. Nuclear Instruments and Methods in Physics Research Section A, 648, S8-S11. http://dx.doi.org/10.1016/j.nima.2011.02.030
- Dubecky, F., Perd’ochová, A., Scepko, P., et al. (2005) Digital X-Ray Portable Scanner Based on Monolithic Semi-Insulating GaAs Detectors: General Description and First “Quantum” Images. Nuclear Instruments and Methods in Physics Research Section A, 546, 118-124. http://dx.doi.org/10.1016/j.nima.2005.03.020
- Dvoryankin, V.F., Dikaev, Yu.M., Krikunov, A.I., Panova, T.M. and Telegin, A.A. (2004) Multielement X-Ray Row Detector on GaAs with Spatial Resolution of 108 μm. Nuclear Instruments and Methods in Physics Research Section A, 531, 87-88. http://dx.doi.org/10.1016/j.nima.2004.05.097
- Dvoryankin, V.F., Dvoryankina, G.G., Dikaev, Yu.M., Ermakov, M.G., Kudryashov, A.A., Petrov, A.G. and Telegin, A.A. (2012). Photovoltaic GaAs Detectors for Digital X-Ray Imaging, Mammography - Recent Advances, Dr. Nachiko Uchiyama (Ed.), InTech. http://dx.doi.org/10.5772/32431
- Tendero, Y. and Gilles, J. (2012) ADMIRE: A Locally Adaptive Single-Image, Non-Uniformity Correction and Denoising Algorithm: Application to Uncooled IR Camera. Proceedings SPIE 8353, Infrared Technology and Applications XXXVIII, 83531O.
- Harris, J.G. and Chiang, Y.M. (1999) Nonuniformity Correction of Infrared Image Sequences Using the Constant-Statistics Constraint. IEEE Transactions on Image Processing, 8, 1148-1151. http://dx.doi.org/10.1109/83.777098
- Li, H.-C. and Song, H.-F. (2011) A Rel-ative Radiometric Correction Method for Linear Array Push-Broom Imagery. Proceedings SPIE 8194, International Symposium on Photoelectronic Detection and Imaging 2011: Advances in Imag-ing Detectors and Applications, 81941L. http://dx.doi.org/10.1117/12.900195
- Ma, W.H., Dong, T., Tian, H. and Ni, J.P. (2014) Line-Scan CCD Camera Calibration in 2D Coordinate Measurement. Optik - International Journal for Light and Electron Optics, 125, 4795-4798. http://dx.doi.org/10.1016/j.ijleo.2014.04.057
- Tyazhev, A.V., Budnitsky, D.L., Koretskay, O.B., Novikov, V.A., Okaevich, L.S., Potapov, A.I., Tolbanov, O.P. and Vorobiev, A.P. (2003) GaAs Radiation Imaging Detectors with an Active Layer Thickness up to 1 mm. Nuclear Instruments and Methods in Physics Research Section A, 509, 34-39. http://dx.doi.org/10.1016/S0168-9002(03)01545-6