Microfluidic Extreme PCR: <1 Minute DNA Amplification in a Thin Film Disposable
- 1 Department of Pathology, University of Utah School of Medicine, Salt Lake City, UT, USA
- 2 Department of Pathology, University of Utah School of Medicine, Salt Lake City, UT, USA
Abstract
Point-of-care diagnostic testing using PCR requires a device that is fast, economical, and practical. Sub-minute amplification has been demonstrated using high concentrations of primers and polymerase in glass capillaries, but its platform is limited to research use. A system using heated copper blocks to clamp a microfluidic flow-through PCR card fabricated from thin film polycarbonate was modeled, fabricated, and tested. Models show that fluid flowing through a thin-film device clamped between temperature-controlled copper blocks equilibrates to a temperature change in 250 milliseconds. A 2-step, 35 cycle PCR with 1.06 second cycles specifically amplified a 69-base pair fragment from a 450-base pair synthetic DNA template of random sequence with the same performance as the glass capillary system. This system demonstrates the feasibility of <1 minute PCR in an inexpensive, disposable sample container.
- Mullis, K.F.F. and Gibbs, R. (1994) The Polymerase Chain Reaction. Birkhauser, Boston. https://doi.org/10.1007/978-1-4612-0257-8
- Farrar, J.S. and Wittwer, C.T. (2015) Extreme PCR: Efficient and Specific DNA Amplification in 15-60 Seconds. Clinical Chemistry, 61, 145-153. https://doi.org/10.1373/clinchem.2014.228304
- Ahrberg, C.D., Manz, A. and Chung, B.G. (2016) Polymerase Chain Reaction in Microfluidic Devices. Lab on a Chip, 16, 3866-3884. https://doi.org/10.1039/C6LC00984K
- Zhang, Y. and Ozdemir, P. (2009) Microfluidic DNA Amplification—A Review. Analytica Chimica Acta, 638, 115-125.
- Zhang, C., et al. (2006) PCR Microfluidic Devices for DNA Amplification. Biotechnology Advances, 24, 243-284.
- Kopp, M.U., Mello, A.J.D. and Manz, A. (1998) Chemical Amplification: Continuous-Flow PCR on a Chip. Science, 280, 4. https://doi.org/10.1126/science.280.5366.1046
- Crews, N., Wittwer, C. and Gale, B. (2008) Continuous-Flow Thermal Gradient PCR. Biomedical Microdevices, 10, 187-195. https://doi.org/10.1007/s10544-007-9124-9
- Lee, N.Y. (2013) Recent Progress in Lab-on-a-Chip Technology and Its Potential Application to Clinical Diagnoses. International Neurourology Journal, 17, 2-10. https://doi.org/10.5213/inj.2013.17.1.2
- Crews, N., et al. (2008) Product Differentiation during Continuous-Flow Thermal Gradient PCR. Lab on a Chip, 8, 919-924. https://doi.org/10.1039/b716437h
- Cao, Q., et al. (2012) Microfluidic Chip for Molecular Amplification of Influenza A RNA in Human Respiratory Specimens. PLoS ONE, 7, e33176. https://doi.org/10.1371/journal.pone.0033176
- Bartholomeusz, D.A., Boutte, R.W. and Andrade, J.D. (2005) Xurography: Rapid Prototyping of Microstructures Using a Cutting Plotter. Journal of Microelectromechanical Systems, 14, 1364-1374. https://doi.org/10.1109/JMEMS.2005.859087
- Focke, M., et al. (2010) Lab-on-a-Foil: Microfluidics on Thin and Flexible Films. Lab on a Chip, 10, 1365-1386. https://doi.org/10.1039/c001195a
- Nellis, G.K.S. (2009) Heat Transfer. Cambridge, New York.