33% Classification Accuracy Improvement in a Motor Imagery Brain Computer Interface
- 1 Polystim Neurotech Lab, Institute of Biomedical Engineering, Polytechnique Montreal, QC, Canada
- 2 Biomedical Engineering Department, Holy Spirit University of Kaslik, Jounieh, Lebanon
- 3 Polystim Neurotech Lab, Institute of Biomedical Engineering, Polytechnique Montreal, QC, Canada
Abstract
A right-hand motor imagery based brain-computer interface is proposed in this work. Such a system requires the identification of different brain states and their classification. Brain signals recorded by electroencephalography are naturally contaminated by various noises and interferences. Ocular artifact removal is performed by implementing an auto-matic method “Kmeans-ICA” which does not require a reference channel. This method starts by decomposing EEG signals into Independent Components; artefactual ones are then identified using Kmeans clustering, a non-supervised machine learning technique. After signal preprocessing, a Brain computer interface system is implemented; physiologically interpretable features extracting the wavelet-coherence, the wavelet-phase locking value and band power are computed and introduced into a statistical test to check for a significant difference between relaxed and motor imagery states. Features which pass the test are conserved and used for classification. Leave One Out Cross Validation is performed to evaluate the performance of the classifier. Two types of classifiers are compared: a Linear Discriminant Analysis and a Support Vector Machine. Using a Linear Discriminant Analysis, classification accuracy improved from 66% to 88.10% after ocular artifacts removal using Kmeans-ICA. The proposed methodology outperformed state of art feature extraction methods, namely, the mu rhythm band power.
- Vidal, J.J. (1973) Toward Direct Brain-Computer Communication. Annual Review of Biophysics and Bioengineering, 2, 157-180. https://doi.org/10.1146/annurev.bb.02.060173.001105
- Baali, H., Khorshidtalab, A., Mesbah, M. and Salami, M.J.E. (2015) A Transform-Based Feature Extraction Approach for Motor Imagery Tasks Classification. IEEE Journal of Translational Engineering in Health and Medicine, 3, 1-8. https://doi.org/10.1109/JTEHM.2015.2485261
- Delgado Saa, J.F. and Cetin, M. (2013) Discriminative Methods for Classification of Asynchronous Imaginary Motor Tasks from EEG Data. IEEE Transactions on Neural Systems and Rehabilitation Engineering, 21, 716-724. https://doi.org/10.1109/TNSRE.2013.2268194
- Sanei, S. and Chambers, J.A. (2007) EEG Signal Processing. John Wiley & Sons Ltd., 35-125. https://doi.org/10.1002/9780470511923
- Assi, E.B. and Rihana, S. (2014) Kmeans-ICA Based Automatic Method for EOG Denoising in Multi-Channel EEG Recordings. Proceedings of 11th IASTED International Conference on Biomedical Engineering, Zurich, 23-25 June 2014, 233-238.
- Kroupi, E., Yazdani, A., Vesin, J.M. and Ebrahimi, T. (2011) Ocular Artifact Removal from EEG: A Comparison of Subspace Pro-jection and Adaptive Filtering Methods. 19th European Signal Processing Conference, Barcelona, 2011, 1395-1399.
- Assi, E.B., Rihana, S. and Sawan, M. (2014) Kmeans-ICA Based Automatic Method for Ocular Artifacts Removal in a Motorimagery Classification. Engineering in Medicine and Biology Society (EMBC), 2014 36th Annual International Conference of the IEEE, Chicago, IL, USA, 26-30 August 2014, 6655-6658. https://doi.org/10.1109/EMBC.2014.6945154
- Croft, R.J. and Barry, R.J. (2000) Removal of Ocular Artifact from the EEG: A Review. Clinical Neurophysiology, 30, 5-19. https://doi.org/10.1016/S0987-7053(00)00055-1
- Gotman J., Skuce, D.R., Thompson, C.J., Gloor, P., Ives, J.R. and Ray, W.F. (1973) Clinical Applications of Spectral Analysis and Extraction of Features from Electroencephalograms with Slow Waves in Adult Patients. Electroencephalography and Clinical Neurophysiology, 35, 225-235.
- Lagerlund, T.D., Sharbrough F.W and Busacker, N.E. (1997) Spatial Filtering of Multichannel Electro-encephalographic Recordings through Principal Component Analysis by Singular Value Decomposition. Journal of Clinical Neurophysiology, 14, 73-82. https://doi.org/10.1097/00004691-199701000-00007
- Romero, S., Mananas, M.A., Riba, J., Morte, A., Gimenez, S., Clos, S. and Barbanoj, M.J. (2004) Evaluation of an Automatic Ocular Filtering Method for Awake Spontaneous EEG Signals Based on Independent Component Analysis. 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, San Francisco, CA, 1-5 September 2004, 925-928. https://doi.org/10.1109/iembs.2004.1403311