Application of quartz crystal nanobalance in conjunction with a net analyte signal based method for simultaneous determination of leucine, isoleucine and valine
- 1
- 2
- 3
Abstract
The aim of the present investigation was to develop a biosensor for the detection of amino acids, Leucine, Isoleucine and Valine based on a quartz crystal nanobalance. leucine (Leu), isoleucine (Ile), and valine (Val) were selectively determined by quartz crystal nanobalance (QCN) sensor in conjunction with net analyte signal (NAS)-based method called HLA/GO. An orthogonal design was applied for the formation of calibration and prediction sets including Leu, Ile and Val compounds. The selection of the optimal time range involved the calculation of the net analyte sig-nal regression plot in any considered time window for each test sample. The searching of a region with maximum linearity of NAS regression plot (minimum error indicator) and minimum of PRESS value was carried out by applying a moving window strategy. On the base of obtained results, the differences on the adsorption profiles in the time range between 1 and 300 s were used to determine mixtures of compounds by HLA/GO method. The results showed that the method was successfully applied for the determina-tion of Leu, Ile and Val.
- Barschak, A. G., Marchesan, C., Sitta, A., Deon, M., Giugliani, R., Wajner, M., and Vargas, C. R., (2008) Maple syrup urine disease in treated patients: Biochemical and oxidative stress profiles, Clinical Biochemistry, 41, 317–324.
- Deng, C. and Deng, Y., (2003) Diagnosis of maple syrup urine disease by determination of l-valine, l-isoleucine, l-leucine and l-phenylalanine in neonatal blood spots by gas chromatography-mass spectrometry, Journal of Chromatogra-phy B, 792, 261–268.
- Bridi, R., Fontella, F. U., Pulrolnik, V., Braun, C. A., Zorzi, G. K., Coelho, D., Wajner, M., Vargas, C. R., and Dutra-Filho, C. S., (2006) A chemically-induced acute model of maple syrup urine disease in rats for neurochemical studies, Journal of Neuroscience Methods, 155, 224–230.
- Lau, K. T., Micklefield, J., and Slater, J. M., (1998) The opti-mization of sorption sensor array for use in ambient conditions, Sens. Actuators. B, Chem., 50, 69–79.
- Sauerbrey, G. Z., (1959) The use of quartz oscillators for weighing thin layers and for microweighing, Phys, 155, 206–222.
- Mirmohseni, A. and Oladegaragoze, A., (2004) Determination of chlorinated aliphatic hydrocarbons in air using a polymer coated quartz crystal microbalance sensor Sensors and Actua-tors B, 102, 261–270.
- Mirmohseni, A. and Oladegaragoze, A., (2003) Determination of Ammonia and Aliphatic amines in Air Using Poly(N-vinylpyrrolidone) Coated Quartz Crystal Microbalance Sensors and Actuators B, 89, 164–172.
- Mirmohseni, A. and Alipour, A., (2002) Construction of a sen-sor for the determination of cyanide in industrial effluents: A method based on Quartz Crystal Microbalance Sensors and Actuators B, 84, 245–251.
- Mirmohseni, A., Shojaei, M., and Farbodi, M., (2008) Applica-tion of a quartz crystal nanobalance to the molecularly im-printed recognition of phenylalanine in solution Biotechnology and bioprocess Engineering, 13, 592–597.
- Shojaei, M., Mirmohseni, A., and Farbodi, M., (2008) Applica-tion of a quartz crystal nanobalance and principal component analysis for the detection and determination of histidine, Anal. Bioanal. Chem., 391, 2875–2880.
- Zhu,W., Wei,W., Nie, L., and Yao, S., (1993) Anal. Chim. Acta, 282, 535–541.
- Nyberg, H., (2008) Multivariate analysis applied to a test pro-cedure for determining gun propelling charge weight Part II, Partial least squares analysis, Chemometrics and Intelligent Laboratory Systems, 92, 118–124.