Imaging of arterial plaque by quadrature swept-source optical coherence tomography with signal to noise ratio enhancements
- 1
- 2
- 3
Abstract
Arterial plaque from a myocardial infarction-prone Watanabe heritable hyperlipidemic (WHHLMI) rabbit is visualized and characterized using a signal to noise ratio enhanced swept-source optical coherence tomography system with a quadrature interferometer (QSS-OCT). A semiconductor optical amplifier is used in the sample arm to amplify the weak signal scattered from arterial plague. Signal to noise ratio improvement are demonstrated in our QSS-OCT system. This finding results into an increase of the penetration depth possible in OCT images, from 1 mm to 2 mm. Preliminary results show that vulnerable plaque with fibrous cap, macrophage accumulations and calcification in the arterial tissue are measurable with our QSS-OCT system.
- Huang, D., Swanson, E.A., Lin, C.P., Schuman, J.S., Stinson, W.G., Chang, W., Hee, M.R., Flotte, T., Gregory, K., Puliafito, C.A. and Fujimoto, J.G. (1991) Optical coherence tomography. Science, 254, 1178-1181. doi:10.1126/science.1957169
- Barils, P. and Schmitt, J. (2009) Current and future developments in intracoronary optical coherence tomography imaging. EuroInterv, 4, 529-533. doi:10.4244/EIJV4I4A89
- Sarunic, M.V., Choma, M.A., Yang, C. and Izatt, J.A. (2005) Instantaneous complex conjugate resolved spectral domain and swept-source OCT using 3 × 3 fiber couplers. Optics Express, 13, 957-967. doi:10.1364/OPEX.13.000957
- Mao, Y., Sherif, S., Flueraru, C. and Chang, S. (2008) 3 × 3 Mach-Zehnder interferometer with unbalanced differential detection for full range swept-source optical coherence tomography. Applied Optics, 47, 2004-2010. doi:10.1364/AO.47.002004
- Flueraru, C., Kumazaki, H., Sherif, S., Chang, S. and Mao, Y. (2007) Quadrature Mach-Zehnder interferometer with application in optical coherence tomography. Journal of Optics A: Pure and Applied Optics, 9, L5-L8. doi:10.1088/1464-4258/9/4/L01
- Rollins, A.M. and Izatt, J.A. (1999) Optimal interferometer designs for optical coherence tomography. Optics Letters, 24, 1484-1486. doi:10.1364/OL.24.001484
- Podoleanu, A.Gh. (2000) Unbalanced versus balanced operation in an optical coherence tomography system. Applied Optics, 39, 173-182. doi:10.1364/AO.39.000173
- Jang, I.K., Bouma, B.E., Kang, D.H., Park, S.J., Park, S.W., Seung, K.B., Choi, K.B., Shishkov, M., K. Schlendorf, Pomerantsev, E., Houser, S.L., Aretz, H.T. and Tearney, G.J. (2002) Visualization of coronary atherosclerotic plaques in patients using optical coherence tomography: Comparison with intravascular ultrasound. Journal of the American College of Cardiology, 39, 604-609. doi:10.1016/S0735-1097(01)01799-5
- Stamper, D., Weissman, N. and Brezinski, M. (2006) Plaque characterization with optical coherence tomography. Journal of the American College of Cardiology, 47, 69-79. doi:10.1016/j.jacc.2005.10.067
- Luz, A., Bisceglia, T., Hughes, C., Tammam, K., Farah, B. and Fajadet, J. (2010) Atherosclerotic plaque prolapse between coronary stent struts visualized by optical coherence tomography. Revista Portuguesa de Cardiologia, 29, 143-146.
- Patel, N.A., Stamper, D.L. and Brezinski, M.E. (2005) Review of the ability of optical coherence tomography to characterize plaque, including a comparison with intravascular ultrasound. Cardiovascular and Interventional Radiology, 28, 1-9. doi:10.1007/s00270-003-0021-1