Effects of Laser Pulse Numbers on Surface Biocompatibility of Titanium for Implant Fabrication
- 1 Department of Mechanical Engineering, University of New Brunswick, Fredericton, Canada
- 2 Department of Mechanical Engineering, University of New Brunswick, Fredericton, Canada
Abstract
Generally, materials with high biocompatibility are more appropriate for bone and tissue transplant applications, due to their higher effectiveness in the healing process and infection problems. This study presents the effects of laser surface texturing on the surface topography properties, roughness, and wettability of thin titanium sheets, which consequently enhance the biocompatibility of this material. Creating line patterns across the surfaces, the titanium samples are prepared using variety of laser parameters. The apatite inducing ability of each sample is tested through the use of simulated body fluid (SBF). The final biocompatibility level of titanium samples is analyzed through wettability, surface angle measurements, and average surface temperature profile. Overall, the effects of laser parameter, pulse numbers, upon the biocompatibility of titanium are thoroughly examined, with results indicating that a scanning speed of 100 μm/ms results in desirable bone type apatite inducing abilities across the surface of treated titanium sheets.
- Hutmacher, D.W. (2000) Scaffolds in Tissue Engineering Bone and Cartilage. Biomaterials, 21, 2529-2543. http://dx.doi.org/10.1016/S0142-9612(00)00121-6
- Ahmmed, K.T., Ling, E.J.Y., Servio, P. and Kietzig, A.M. (2015) Introducing a New Optimization Tool for Femtosecond Laser-Induced Surface Texturing on Titanium, Stainless Steel, Aluminum and Copper. Optics and Lasers in Engineering, 66, 258-268. http://dx.doi.org/10.1016/j.optlaseng.2014.09.017
- Coelho, P.G., Granjeiro, J.M., Romanos, G.E., Suzuki, M., Silva, N.R., Cardaropoli, G., Thompson, V.P. and Lemons, J.E. (2009) Basic Research Methods and Current Trends of Dental Implant Surfaces. Journal of Biomedical Materials Research Part B: Applied Biomaterials, 88, 579-596. http://dx.doi.org/10.1002/jbm.b.31264
- Ulerich, J.P., Ionescu, L.C., Chen, J.B., Soboyejo, W.O. and Arnold, C.B. (2007) Modifications of Ti-6Al-4V Surfaces by Direct-Write Laser Machining of Linear Grooves. Proceedings of SPIE 6458, Photon Processing in Microelectronics and Photonics VI, 645819. http://dx.doi.org/10.1117/12.713964
- Erdoan, M., Oktem, B., Kalaycolu, H., Yava?, S., Mukhopadhyay, P.K., Eken, K., Ilday, F., et al. (2011) Texturing of Titanium (Ti6Al4V) Medical Implant Surfaces with MHz-Repetition-Rate Femtosecond and Picosecond Yb- Doped Fiber Lasers. Optics Express, 19, 10986-10996. http://dx.doi.org/10.1364/OE.19.010986
- Kokubo, T. and Takadama, H. (2006) How Useful Is SBF in Predicting in Vivo Bone Bioactivity? Biomaterials, 27, 2907-2915. http://dx.doi.org/10.1016/j.biomaterials.2006.01.017
- Mirhosseini, N., Crouse, P.L., Schmidth, M.J.J., Li, L. and Garrod, D. (2007) Laser Surface Micro-Texturing of Ti-6Al-4V Substrates for Improved Cell Integration. Applied Surface Science, 253, 7738-7743. http://dx.doi.org/10.1016/j.apsusc.2007.02.168
- van Tol, A.F., Tibballs, J.E., Gjerdet, N.R. and Ellison, P. (2013) Experimental Investigation of the Effect of Surface Roughness on Bone-Cement-Implant Shear Bond Strength. Journal of the Mechanical Behavior of Biomedical Materials, 28, 254-262. http://dx.doi.org/10.1016/j.jmbbm.2013.08.005
- Tavangar, A., Tan, B. and Venkatakrishnan, K. (2011) Synthesis of Bio-Functionalized Three-Dimensional Titania Nanofibrous Structures Using Femtosecond Laser Ablation. Acta Biomaterialia, 7, 2726-2732. http://dx.doi.org/10.1016/j.actbio.2011.02.020
- Wang, H.S., Liang, C.Y., Yang, Y. and Li, C.Y. (2010) Bioactivities of a Ti Surface Ablated with a Femtosecond Laser through SBF. Biomedical Materials, 5, Article ID: 054115. http://dx.doi.org/10.1088/1748-6041/5/5/054115