In this work an impedimetric immunosensor based on affinity immobilization method of a biotin labelled anti-human IgG antibody, used as a model system, was reported. The experimental procedure involves the growth of a self-assembled monolayer of a thiol (cysteamine) carrying terminal amine groups on gold electrodes. Glutarardehyde, a homobifunctional cross-linker, was used as a coupling reagent for the covalent linking of avidin to the amine groups of cysteamine. The attachment of the biotin labeled antibodies (anti-Human IgG) to the subsequent modified gold electrode was achieved by affinity interactions tacking advantage of the strong avidin-biotin bridge. The stepwise assembly process of the electrode was interrogated by means of cyclic voltammetry, electrochemical impedance spectroscopy and contact angle measurements. The response of the antibody modified electrode to their target antigens was investigated in the presence of BSA (bovin serum albumin) in order to alleviate non-specific adsorption problems. A proposed electrical model was used to analyse the experimental data. The resulting immunosensor has a linear dynamic range of 100 - 900 ng ? ml – 1 of antigen and a detection limit of 100 ng ? ml – 1.
Katz, E. and Willner, I. (2003) Probing Biomolecular Interactions at Conductive and Semiconductive Surfaces by Impedance Spectroscopy: Routes to Impedimetric Immunosensors, DNA Sensors and Enzyme Biosensors. Electroanalysis, 15, 913-947. http://dx.doi.org/10.1002/elan.200390114
Guan, J.-G., Miao, Y.-Q. and Zhang, Q.-J. (2004) Impedimetric Biosensors. Journal of Bioscience & Bioengineering, 97, 219-226. http://dx.doi.org/10.1016/S1389-1723(04)70195-4
Jonathan, S.D. and Nader, P. (2007) Label-Free Impedance Biosensors: Opportunities and Challenges. Electroanalysis, 19, 1239-1257. http://dx.doi.org/10.1002/elan.200603855
Omowunmi, A.S., Austin, O.A. and Ailing, Z. (2009) Status of Biomolecular Recognition Using Electrochemical Techniques. Biosensors & Bioelectronics, 24, 2749-2765. http://dx.doi.org/10.1016/j.bios.2008.10.003
Barbero, G., Alexe-Ionescu, A.L. and Lelidis, I. (2005) Significance of Small Voltage in Impedance Spectroscopy Measurements on Electrolytic Cells. Journal of Applied Physics, 98, Article ID: 113703. http://dx.doi.org/10.1063/1.2137444
Barsoukov, E. and Macdonald, J.R. (2005) Impedance Spectroscopy Theory, Experiment, and Applications. 2nd Edition, Wiley Interscience Publication, New Jersey. http://dx.doi.org/10.1002/0471716243
Jung, Y., Jeong, J.Y. and Chung, B.H. (2008) Recent Advances in Immobilization Methods of Antibodies on Solid Supports. Analyst, 133, 697-701. http://dx.doi.org/10.1039/b800014j
Asta, M. and Almira, R. (2013) Site-Directed Antibody Immobilization Techniques for Immunosensors. Biosensors & Bioelectronics, 50, 460-471. http://dx.doi.org/10.1016/j.bios.2013.06.060
Jaroslava, T. (1999) Oriented Immobilization of Biologically Active Proteins as a Tool for Revealing Protein Interactions and Function. Journal of Chromatography B, 722, 11-31. http://dx.doi.org/10.1016/S0378-4347(98)00434-4
Ouerghi, O., Senillou, A., Jaffrezic-Renault, N., Martelet, C., Ben Ouada, H. and Cosnier, S. (2001) Gold Electrode Functionalized by Electropolymerization of a Cyano N-Substituted Pyrrole: Application to an Impedimetric Immunosensor. Journal of Electroanalytical Chemistry, 501, 62-69. http://dx.doi.org/10.1016/S0022-0728(00)00485-X
Elshafey, R., Tavares, A.C., Siaj, M. and Zourob, M. (2013) Electrochemical Impedance Immunosensor Based on Gold Nanoparticles-Protein G for the Detection of Cancer Marker Epidermal Growth Factor Receptor in Human Plasma and Brain Tissue. Biosensors & Bioelectronics, 50, 143-149. http://dx.doi.org/10.1016/j.bios.2013.05.063
Wan, Y., Su, Y., Zhu, X.H., Liu, G. and Fan, C.H. (2013) Development of Electrochemical Immunosensors towards Point of Care Diagnostics. Biosensors & Bioelectronics, 47, 1-11. http://dx.doi.org/10.1016/j.bios.2013.02.045
Samanta, D. and Sarkar, A. (2011) Immobilization of Bio-Macromolecules on Self-Assembled Monolayers: Methods and Sensor Applications. Chemical Society Reviews, 40, 2567-2592. http://dx.doi.org/10.1039/c0cs00056f
Ouerghi, O., Touhami, A., Jaffrezic-Renault, N., Martelet, C., Ouada, H.B. and Cosnier, S. (2004) Electrodeposited Biotinylated Polypyrrole as an Immobilization Method for Impedimetric Immunosensors. IEEE Sensors Journal, 4, 559-567. http://dx.doi.org/10.1109/JSEN.2004.832858
Da Silva, S., Grosjean, L., Ternan, N., Mailley, P., Livache, T. and Cosnier, S. (2004) Biotinylated Polypyrrole Films: An Easy Electrochemical Approach for the Reagentless Immobilization of Bacteria on Electrode Surfaces. Bioelectrochemistry, 63, 297-301. http://dx.doi.org/10.1016/j.bioelechem.2003.09.027
Cosnier, S. and Lepellec, A. (1999) Poly(pyrrole-biotin): A New Polymer for Biomolecule Grafting on Electrode Surfaces. Electrochimica Acta, 44, 1833-1836. http://dx.doi.org/10.1016/S0013-4686(98)00294-1
Ballesta-Claver, J., Ametis-Cabello, J., Morales-Sanfrutos, J., Megía-Fernández, A., Valencia-Mirón, M.C., Santoyo-González, F. and Capitán-Vallvey, L.F. (2012) Electrochemiluminescent Disposable Cholesterol Biosensor Based on Avidin-Biotin Assembling with the Electroformed Luminescent Conducting Polymer Poly(luminol-biotinylated pyrrole). Analytica Chimica Acta, 754, 91-98. http://dx.doi.org/10.1016/j.aca.2012.10.006
Dupont-Filliard, A., Billon, M., Livache, T. and Guillerez, S. (2004) Biotin/Avidin System for the Generation of Fully Renewable DNA Sensor Based on Biotinylated Polypyrrole Film. Analytica Chimica Acta, 515, 271-277. http://dx.doi.org/10.1016/j.aca.2004.03.072
Ouerghi, O., Touhami, A., Jaffrezic-Renault, N., Martelet, C., Ben Ouada, H. and Cosnier, S. (2002) ImpedimetricImmunosensor Using Avidin-Biotin for Antibody Immobilization. Bioelectrochemistry, 56, 131-133. http://dx.doi.org/10.1016/S1567-5394(02)00029-4
Wilchek, M. and Bayer, E.A. (1989) Avidin-Biotin Technology Ten Years on: Has It Lived up to Its Expectations? Trends in Biochemical Sciences, 14, 408-412. http://dx.doi.org/10.1016/0968-0004(89)90289-2
Cui, X.Q., Pei, R.J., Wang, Z.X., Yang, F., Ma, Y., Dong, S.J. and Yang, X.R. (2003) Layer-by-Layer Assembly of Multilayer Films Composed of Avidin and Biotin-Labeled Antibody for Immunosensing. Biosensors & Bioelectronics, 18, 59-67. http://dx.doi.org/10.1016/S0956-5663(02)00114-8
Chaki, N.K. and Vijayamohanan, K. (2002) Self-Assembled Monolayers as a Tunable Platform for Biosensor Applications. Biosensors & Bioelectronics, 17, 1-12. http://dx.doi.org/10.1016/S0956-5663(01)00277-9
Bedford, E.E., Boujday, S., Humblot, V., Gu, F.X. and Pradier, C.-M. (2014) Effect of SAM Chain Length and Binding Functions on Protein Adsorption: β-Lactoglobulin and Apo-Transferrin on Gold. Colloids and Surfaces B: Biointerfaces, 116, 489-496. http://dx.doi.org/10.1016/j.colsurfb.2014.01.031
Xue, Q.N., Bian, C., Tong, J.H., Sun, J.Z., Zhang, H. and Xia, S.H. (2011) CMOS and MEMS Based Micro Hemoglobin-A1c Biosensors Fabricated by Various Antibody Immobilization Methods. Sensors & Actuators A: Physical, 169, 282-287. http://dx.doi.org/10.1016/j.sna.2011.01.017
Hnaien, M., Diouani, M.F., Helali, S., Hafaid, I., Hassen, W.M., Renault, N.J., Ghram, A. and Abdelghani, A. (2008) Immobilization of Specific Antibody on SAM Functionalized Gold Electrode for Rabies Virus Detection by Electrochemical Impedance Spectroscopy. Biochemical Engineering Journal, 39, 443-449. http://dx.doi.org/10.1016/j.bej.2007.09.018
Elshafey, R., Tlili, C., Abulrob, A., Tavares, A.C. and Zourob, M. (2013) Label-Free Impedimetric Immunosensor for Ultra-Sensitive Detection of Cancer Marker Murine Double Minute 2 in Brain Tissue. Biosensors & Bioelectronics, 39, 220-225. http://dx.doi.org/10.1016/j.bej.2007.09.018
Yabuki, S., Mizutani, F., Sato, Y. and Hirata, Y. (2003) Immobilization of Polyglutamate-Glucose Oxidase onto a Cysteamine-Modified Gold Electrode. Sensors & Actuators B: Chemical, 91, 187-190. http://dx.doi.org/10.1016/S0925-4005(03)00086-8
Akin, M., Yuksel, M., Geyik, C., Odaci, D., Bluma, A., Höpfner, T., Beutel, S., Scheper, T. and Timur, S. (2010) Alcohol Biosensing by Polyamidoamine (PAMAM)/Cysteamine/Alcohol Oxidase-Modified Gold Electrode. Biotechnology Progress, 26, 896-906. http://dx.doi.org/10.1002/btpr.372
Ferretti, S., Paynter, S., Russell, D.A. and Sapsford, K.E. (2000) Self-Assembled Monolayers: A Versatile Tool for the Formulation of Bio-Surfaces. Trends in Analytical Chemistry, 19, 530-540. http://dx.doi.org/10.1016/S0165-9936(00)00032-7
Zhang, Y.W., Li, Y.Q., Wu, W.J., Jiang, Y.R. and Hu, B.R. (2014) Chitosan Coated on the Layers’ Glucose Oxidase Immobilized on Cysteamine/Au Electrode for Use as Glucose Biosensor. Biosensors & Bioelectronics, 60, 271-276. http://dx.doi.org/10.1016/j.bios.2014.04.035
Poitras, C. and Tufenkji, N. (2009) A QCM-D-Based Biosensor for E. coli O157:H7 Highlighting the Relevance of the Dissipation Slope as a Transduction Signal. Biosensors & Bioelectronics, 24, 2137-2142. http://dx.doi.org/10.1016/j.bios.2008.11.016
Darowicki, K. (1995) The Amplitude Analysis of Impedance Spectra. Electrochimica Acta, 40, 439-445. http://dx.doi.org/10.1016/0013-4686(94)00303-I
Martell, A.E. and Smith, R.M. (1975) Critical Stability Constants. Plenum Press, New York.
Hu, X.-Y., Xiao, Y. and Chen, H.-Y. (1999) Adsorption Characteristics of Fe(CN)63–/4– on Au Colloids as Monolayer Films on Cysteamine-Modified Gold Electrode. Journal of Electroanalytical Chemistry, 466, 26-30. http://dx.doi.org/10.1016/S0022-0728(99)00113-8
Kerekovic, I., Milardovic, S., Palcic, M. and Grabaric, Z. (2014) Characterization of Cysteamine Self-Assembled on Gold Functionalized with Nitrilotriacetic Acid and Evaluation of Copper(II) Binding Capacity with Adsorption Transfer Stripping Voltammetry. Journal of Electroanalytical Chemistry, 724, 103-110. http://dx.doi.org/10.1016/j.jelechem.2014.04.017
Campuzano, S., Pedrero, M., Montemayor, C., Fatás, E. and Pingarrón, J.M. (2006) Characterization of Alkanethiol-Self-Assembled Monolayers Modified Gold Electrodes by Electrochemical Impedance Spectroscopy. Journal of Electroanalytical Chemistry, 586, 112. http://dx.doi.org/10.1016/j.jelechem.2005.09.007
Ramos-Jesus, J., Carvalho, K.A., Fonseca, R.A.S., Oliveira, G.G.S., Barrouin Melo, S.M., Alcantara-Neves, N.M. and Dutra, R.F. (2011) A Piezoelectric Immunosensor for Leishmania chagasi Antibodies in Canine Serum. Analytical and Bioanalytical Chemistry, 401, 917-925. http://dx.doi.org/10.1007/s00216-011-5136-7
Campuzano, S., Galvez, R., Pedrero, M., De Villena, F.J.M. and Pingarron, J.M. (2002) Preparation, Characterization and Application of Alkanethiol Self-Assembled Monolayers Modified with Tetrathiafulvalene and Glucose Oxidase at a Gold Disk Electrode. Journal of Electroanalytical Chemistry, 526, 92-100. http://dx.doi.org/10.1016/S0022-0728(02)00753-2
Yu, H.Z., Zhao, J.W., Wang, Y.Q., Cai, S.M. and Liu, Z.F. (1997) Fabricating an Azobenzene Self-Assembled Monolayer via Step-by-Step Surface Modification of a Cysteamine Monolayer on Gold. Journal of Electroanaiytical Chemistry, 438, 221-224. http://dx.doi.org/10.1016/S0022-0728(97)00055-7
Ehret, R., Baumann, W., Brischwein, M., Schwinde, A., Stegbauer, K. and Wolf, B. (1997) Monitoring of Cellular Behaviour by Impedance Measurements on Interdigitated Electrode Structures. Biosensors & Bioelectronics, 12, 29-41. http://dx.doi.org/10.1016/0956-5663(96)89087-7
Patolsky, F., Zayats, M., Katz. E. and Willner, I. (1999) Precipitation of an Insoluble Product on Enzyme Monolayer Electrodes for Biosensor Applications: Characterization by Faradaic Impedance Spectroscopy, Cyclic Voltammetry, and Microgravimetric Quartz Crystal Microbalance Analyses. Analytical Chemistry, 71, 3171-3180. http://dx.doi.org/10.1021/ac9901541
Canbaz, M.Ç., Simsek, Ç.S. and Sezgintürk, M.K. (2014) Electrochemical Biosensor Based on Self-Assembled Monolayers Modified with Gold Nanoparticles for Detection of HER-3. Analytica Chimica Acta, 814, 31-38. http://dx.doi.org/10.1016/j.aca.2014.01.041
Bart, M., Stigter, E.C.A., Stapert, H.R., De Jong, G.J. and Van Bennekom, W.P. (2005) On the Response of a Label-Free Interferon-Gamma Immunosensor Utilizing Electrochemical Impedance Spectroscopy. Biosensors & Bioelectronics, 21, 49-59. http://dx.doi.org/10.1016/j.bios.2004.10.009
Rodriguez, M.L.L., Benimeli, C., Madride, R.E. and Giacomelli, C.E. (2015) A Simple Streptomyces Spore-Based Impedimetric Biosensor to Detect Lindane Pesticide. Sensors and Actuators B: Chemical, 207, 447-454. http://dx.doi.org/10.1016/j.snb.2014.10.030