Objective Assessment of Skin Tightening Using Multisource, Phase-Controlled Radiofrequency in Asians
- 1 Clinica Tanaka Plastic, Reconstructive Surgery and Anti-aging Center, Matsumoto, Japan Department of Dermatology, Tokyo Women’s Medical University, Tokyo, Japan Department of Applied Life Sciences, Niigata University of Pharmacy and Applied Life Sciences, Niigata, Japan
Abstract
Background: Radiofrequency has been proven to penetrate deeper than optical light sources independent of skin color allowing a safer treatment for the Asian skin type. Many studies have indicated the efficacy of various types of devices, but have not included a sufficient objective evaluation. Multisource radiofrequency uses multiple phase controlled ra diofrequency generators with real time impedance control, allowing painless, deeper dermal heating with better adapta tion to differences in individual skin impedance. In this study we used three-dimensional imaging for the objective evaluation of facial skin tightening by multisource phase-controlled radiofrequency. Methods: Twenty Japanese patients were treated with a multisource phase-controlled radiofrequency device. Three-dimensional imaging was performed with a Canfield Scientific Vectra camera and software, and quantitative volume measurements were taken to evaluate the change in the post-treatment volume. The patients then provided subjective assessments. Results: Ob jective assessments of the treated cheek volume evaluated by a three-dimensional color schematic representation with quantitative volume measurements showed significant improvement three months after the final treatment. The mean volume reduction at the last post-treatment visit was 3.878 ± 2.86 mL. The post-treatment volume was significantly reduced compared to the pretreatment volume in all of the volunteers ( P = 0.0007). Ninety-five percent of volunteers reported satisfaction with the improvement of skin laxity, and ninety percent of volunteers reported satisfaction with the improvement of wrinkles, such as the nasolabial folds. Conclusions: The advantages of these multisource phase-controlled radiofrequency treatments are its high efficacy for skin tightening associated with minimal level of discomfort, minimal side effects, a nd low cost. Taken together, these characteristics facilitate the ability to give repeated treatments as a stand alone treatment or adjunct to surgery. This study provides for the first time a qualitative and quantitative volumetric assessment, proving the ability of the technology to reduce the volum e through non invasive skin tightening.
- M. Elman and Y. Harth, “Novel Multi-Source PhaseControlled Radiofrequency Technology for Non-Ablative and Micro-Ablative Treatment of Wrinkles, Lax Skin and Acne Scars,” Laser Therapy, Vol. 20, No. 2, 2011, pp. 139-144. doi:10.5978/islsm.20.139
- Y. Tanaka, K. Matsuo, S. Yuzuriha and H. Shinohara, “Differential Long-Term Stimulation of Type I versus Type III Collagen after Infrared Irradiation,” Dermatologic Surgery, Vol. 35, No. 7, 2009, pp. 1099-1104. doi:10.1111/j.1524-4725.2009.01194.x
- Y. Tanaka, K. Matsuo and S. Yuzuriha, “Long-Term Evaluation of Collagen and Elastin Following Infrared (1100 to 1800 nm) Irradiation,” Journal of Drugs in Dermatology, Vol. 8, No. 8, 2009, pp. 708-712.
- Y. Tanaka, K. Matsuo and S. Yuzuriha, “Long-Term Histological Comparison between Near-Infrared Irradiated Skin and Scar Tissues,” Clinical, Cosmetic and Investigational Dermatology, Vol. 3, 2010, pp. 143-149. http://www.dovepress.com/articles.php?article_id=5752
- Y. Tanaka, K. Matsuo and S. Yuzuriha, “Long-Lasting Muscle Thinning Induced by Infrared Irradiation Specialized with Wavelength and Contact Cooling: A Preliminary Report,” ePlasty, Vol. 10, 2010, p. e40. http://www.eplasty.com/index. php? option=com_content&view= article&id= 453&catid=171:volume-10-eplasty-2010
- Y. Tanaka, K. Matsuo and S. Yuzuriha, “Long-Lasting Relaxation of Corrugator Supercilii Muscle Contraction Induced by Near Infrared Irradiation,” ePlasty, Vol. 11, 2011, p. e6. http://www.eplasty.com/index.php?option=com_content&view=article&id=519&catid=172:volume-11-eplasty-2011
- Y. Tanaka, K. Matsuo and S. Yuzuriha, “Objective Assessment of Skin Rejuvenation Using Near-Infrared 1064nm Neodymium: YAG Laser in Asians,” Clinical, Cosmetic and Investigational Dermatology, Vol. 4, 2011, pp. 123-130. http://www.dovepress.com/articles.php?article_id=7972
- Y. Tanaka, K. Matsuo and S. Yuzuriha, “Near-Infrared Irradiation Non-Thermally Induces Long-Lasting Vasodilation by Causing Apoptosis of Vascular Smooth Muscle Cells,” ePlasty, Vol. 11, 2011, p. e22. http://www.eplasty.com/index.php?option=com_content&view=article&id=541&catid=172:volume-11-eplasty-2011
- Y. Tanaka, K. Matsuo and S. Yuzuriha, “Near-Infrared Irradiation Non-Thermally Affects Subcutaneous Adipocytes and Bones,” ePlasty, Vol. 11, 2011, p. e12. http://www.eplasty.com/index.php?option=com_content&view=article&id=528&catid=172:volume-11-eplasty-2011
- Y. Tanaka, K. Matsuo, S. Yuzuriha, H. Yan and J. Nakayama, “Non-Thermal Cytocidal Effect of Infrared Irradiation on Cultured Cancer Cells Using Specialized Device,” Cancer Science, Vol. 101, No. 6, 2010, pp. 1396-1402. doi:10.1111/j.1349-7006.2010.01548.x