Dosimetric and Efficiency Comparisons between Volumetric Modulated Arc Therapy and IMRT for Cervical-Thoracic Esophageal Cancers
- 1 Department of Radiation Oncology, Southern Theater Command Air Force Hospital, Guangzhou, China
- 2 School of Medical Information and Engineering, Guangdong Pharmaceutical University, Guangzhou, China
- 3 Department of Radiation Oncology, Nanfang Hospital, Southern Medical University, Guangzhou, China
- 4 Department of Radiation Oncology, Xiang’an Hospital of Xiamen University, School of Medicine, Xiamen University, Xiamen, China
- 5 Department of Radiation Oncology, Xiang’an Hospital of Xiamen University, School of Medicine, Xiamen University, Xiamen, China
- 6 Department of Radiation Oncology, Xiang’an Hospital of Xiamen University, School of Medicine, Xiamen University, Xiamen, China
Abstract
Purpose: This study aims to evaluate the treatment plans of Volumetric-mo dulated arc therapy (VMAT) and intensity-modulated radiation therapy (IMRT) techniques for cervical-thoracic esophageal cancers. Methods and Materials: Sixty patients were retrospectively identified. Several parameters were evaluated based on target conformity and dose-volume histograms of organs at risk (lung, spinal cord, and heart). A phantom for time comparison was also assessed for each plan. Results: The IMRT plans (5f-IMRT: V95% = 99.4 ± 0.3, 7f-IMRT: V95% = 99.8 ± 0.1) results in better PTV coverage than RA plans (Single-arc: V95% = 95.8 ± 3.2, Double-arc: V95% = 95.4 ± 2.3). The target dose conformity of the 5f-IMRT plan was inferior to all plans (CI = 70.4 ± 7.1). The Single-arc plan achieved the best conformity (CI = 72.5 ± 4.6), whereas the Double-arc plan (CI = 72.1 ± 5.1) was slightly inferior to the Single-arc plan but superior to the 7f-IMRT plan (CI = 71.7 ± 8.6). The total MU was reduced by 42.1% in VMAT plan. The average MU needed to deliver the dose of 60 Gy for Single-arc (423.5 ± 52.1 MU) was found to be the least. Similarly, the average MU for the 5f-IMRT, 7f-IMRT and Double-arc were 868.2 ± 182.0 MU, 870.0 ± 225.3 MU and 548.8 ± 47.2 MU, respectively. The delivery time in VMAT plans was reduced from 193.8 seconds to 99.2 second s by around 48.8% compared to IMRT plans. Co nclusion: For similar PTV parameters, VMAT delivers a lower dose t o organs at risk than IMRT in a shorter time, and this has warranted clinical implementation.
- Herskovic, A., Martz, K., al-Sarraf, M., Leichman, L., Brindle, J., Vaitkevicius, V., Cooper, J., Byhardt, R., Davis, L. and Emami, B. (1992) Combined Chemotherapy and Radiotherapy Compared with Radiotherapy Alone in Patients with Cancer of the Esophagus. The New England Journal of Medicine, 326, 1593-1598. https://doi.org/10.1056/NEJM199206113262403
- Minsky, B.D., Pajak, T.F., Ginsberg, R.J., Pisansky, T.M., Martenson, J., Komaki, R., Okawara, G., Rosenthal, S.A. and Kelsen, D.P. (2002) INT 0123 (Radiation Therapy Oncology Group 94-05) Phase III Trial of Combined-Modality Therapy for Esophageal Cancer: High-Dose Versus Standard-Dose Radiation Therapy. Journal of Clinical Oncology, 20, 1167-1174. https://doi.org/10.1200/JCO.2002.20.5.1167
- Xu, C., Xi, M., Komaki, R., Balter, P.A., Huang, M.L., Hobbs, B.P., Wang, L.H. and Lin, S.H. (2017) Dosimetric and Clinical Outcomes after Volumetric Modulated Arc Therapy for Carcinoma of the Thoracic Esophagus. Advances in Radiation Oncology, 2, 325-332. https://doi.org/10.1016/j.adro.2017.03.006
- Munch, S., Oechsner, M., Combs, S.E. and Habermeh, D. (2017) DVH-and NTCP-Based Dosimetric Comparison of Different Longitudinal Margins for VMAT-IMRT of Esophageal Cancer. Radiation Oncology, 12, Article No. 128128. https://doi.org/10.1186/s13014-017-0871-3
- Huang, J.-H., Wu, X.-X., Lin, X., et al. (2019) Evaluation of Fixed-Jaw IMRT and Tangential Partial-VMAT Radiotherapy Plans for Synchronous Bilateral Breast Cancer Irradiation Based on a Dosimetric Study. Journal of Applied Clinical Medical Physics, 20, 31-41. https://doi.org/10.1002/acm2.12688
- Li, Y., Wang, J., Tan, L., Hui, B.N., Ma, X.W., Yan, Y.L., Xue, C.F., Shi, X.T., Drokow, E.K. and Ren, J. (2018) Dosimetric Comparison between IMRT and VMAT in Irradiation for Peripheral and Central Lung Cancer. Oncology Letters, 15, 3735-3745. https://doi.org/10.3892/ol.2018.7732
- Liu, Y.-C., Chang, H.-M., Lin, H.-H., Lu, C.-C. and Lai, L.-H. (2020) Dosimetric Comparison of Intensity-Modulated Radiotherapy Volumetric Modulated Arc Therapy and Hybrid Three-Dimensional Conformal Radiotherapy/Intensity-Modulated Radiotherapy Techniques for Right Breast Cancer. Journal of Clinical Medicine, 9, 3884. https://doi.org/10.3390/jcm9123884
- Bedford, J.L., Hansen, N.V., McNair, H.A., Aitken, A.H., Brock, J.E., Warrington, A.P. and Brada, M. (2008) Treatment of Lung Cancer Using Volumetric Modulated Arc Therapy and Image Guidance: A Case Study. Acta Oncologica, 47, 1438-1443. https://doi.org/10.1080/02841860802282778